Plan Review Stops For Permit 20050839 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-12-03 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-12-03 |
Time |
13:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2020-11-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-13 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-13 |
Time |
10:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-29 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-29 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-09-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-15 |
Time |
14:38 |
Sent To |
|
|
Notes |
2020-09-15 14:57:09 | SFR ADDITION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) CANNOT USE A "NAMI" APPROVED CERTIFICATION FOR THE | | SINGLE HUNG WINDOWS. MUST USE A MIAMI DADE OR FLORIDA | | STATE APPROVED PRODUCT APPROVAL. PLEASE PROVIDE | | COMPLETE (FRONT PAGES AND THE INSTALLATION | | INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE PRODUCT | | APPROVALS FOR THE NEW EXTERIOR WINDOWS, ROOFING SYSTEM | | TO BE USED ETC.. PRODUCT APPROVALS NEED TO BE REVIEWED | | AND MARKED APPROVED BY THE BUILDING DESIGNER OF RECORD | | (ARCHITECT). | | | | 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE ROOFING SYSTEM TO BE USED. | | PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE | | PRODUCT APPROVAL - IF NEEDED PLEASE PROVIDE SIGNED AND | | SEALED ADDITIONAL ATTACHMENT DETAILS FROM AN ARCHITECT | | OR ENGINEER FOR THE ROOF ZONES 2 AND 3 WHICH MAY | | REQUIRE A HIGHER WIND PRESSURE - SEE NOTES ON THE | | PRODUCT APPROVAL. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-22 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-22 |
Time |
11:10 |
Sent To |
|
|
Notes |
2020-07-22 12:40:17 | SFR ADDITION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS, | | ROOFING SYSTEM TO BE USED ETC.. PRODUCT APPROVALS NEED | | TO BE REVIEWED AND MARKED APPROVED BY THE BUILDING | | DESIGNER OF RECORD (ARCHITECT). | | 2) PLEASE PROVIDE A SIGNED AND SEALED SURVEY/SITE PLAN | | SHOWING THE BUILDING SETBACKS, EASEMENTS, LOT DRAINAGE | | ETC. | | 3) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE ROOFING SYSTEM TO BE USED. | | PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE | | PRODUCT APPROVAL - IF NEEDED PLEASE PROVIDE SIGNED AND | | SEALED ADDITIONAL ATTACHMENT DETAILS FROM AN ARCHITECT | | OR ENGINEER FOR THE ROOF ZONES 2 AND 3 WHICH MAY | | REQUIRE A HIGHER WIND PRESSURE - SEE NOTES ON THE | | PRODUCT APPROVAL. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2020-07-22 |
Time |
19:50 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2020-07-22 |
Time |
19:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2021-01-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-01-14 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-01-06 |
Time |
10:17 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-12-03 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-23 |
Time |
13:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-11-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-13 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-03 |
Time |
16:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-29 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-20 |
Time |
13:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-09-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-09-18 |
Time |
06:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-09-08 |
Time |
13:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-08-10 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-08-10 |
Time |
12:56 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-07-01 |
Time |
08:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-02-04 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-02-04 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-01-19 |
Time |
08:44 |
Sent To |
|
|
Notes |
2021-02-04 11:40:31 | 2/4/21 NO FEES DUE PER IMPACT OFFICE. LEM | 2021-01-19 22:46:45 | 01/19/21 READY TO BE REVIWED. EMAILED PBC IMPACT FEES | | OFFICE. QUESTIONNAIRE UPLOADED. CC |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-22 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-22 |
Time |
12:40 |
Sent To |
|
|
Notes |
2020-07-22 12:41:21 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2020-10-28 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-10-28 |
Time |
07:17 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-10-28 |
Time |
07:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2020-09-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-09-16 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-09-16 |
Time |
07:25 |
Sent To |
|
|
Notes |
2020-09-16 08:29:39 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT-20050839 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SHOW RETURN AIR PATH FOR THE PROPOSED FAMILY | | ROOM. FBC FS 107.2.1 | | | | 2) PLEASE SHOW THE RETURN AIR IS A BALANCED. MAKE SURE | | THE RETURN AIR DUCTS ARE 1 ? TIMES THE CROSS SECTIONAL | | AREA (SQUARE INCHES) OF THE SUPPLY DUCT ENTERING THE | | ROOM. FBC RES M1602.3 | | | | 3) PLEASE PROVIDE DISTANCE OF RETURN AIR GRILL TO | | COOKING APPLIANCE IN THE KITCHEN. FBC RES M1602.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-07-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-07-15 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-07-15 |
Time |
09:03 |
Sent To |
|
|
Notes |
2020-07-15 09:34:29 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20050839 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-1: PLEASE PROVIDE THE ENERGY CALCS AND THE | | MANUAL J FOR THE NEW MECHANICAL SYSTEM. FBC EC | | 101.5.1.1.2 | | | | 2) PLEASE SHOW RETURN AIR PATH FOR THE PROPOSED FAMILY | | ROOM. FBC RES M1602.3 | | | | 3) PLEASE SHOW TERMINATION FOR THE DRYER DUCT. PLEASE | | PROVIDE THE DEVELOPED LENGTH OF THE DRYER DUCT. FBC FS | | 107.2.1 | | | | 4) PLEASE PROVIDE INFORMATION FOR THE BATH EXHAUST FANS | | AND THE LOCATION OF EXTERIOR TERMINATION. FBC FS | | 107.2.1 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2020-10-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-10-21 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-10-21 |
Time |
07:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-09-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-09-09 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-09-09 |
Time |
09:55 |
Sent To |
|
|
Notes |
2020-09-09 11:04:35 | 2ND REVIEW FBC-2017 RES. | | PERMIT-20050839 | | 9/9/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET A5.0: COMMENT #3 FROM THE 1ST REVIEW STILL | | EXISTS. THE REQUESTED SPECS FOR THE RHEEM TANKLESS | | WATER HEATER WERE NOT SUBMITTED. REVIEW OF THE SPECS ON | | THE RHEEM WEBSITE INDICATE THE SELECTED RETEX-13 IS | | UNDERSIZED AND WILL NOT PROVIDE ADEQUATE HOT WATER TO | | THE FIXTURES. ON PAGE 2 OF THE MANUFACTURER'S SPECS THE | | SIZING GUIDE CHART INDICATES THE UNIT WILL PROVIDE | | MAXIMUM 2.0 GPM FLOW WITH AN INLET WATER TEMPERATURE OF | | 70 DEGREES F. LIKEWISE THE TEMPERATURE RISE CHART ON | | PAGE 1 INDICATES 2.0 GPM FLOW FOR A TEMPERATURE RISE OF | | 44 DEGREES F. PLEASE REFER TO TABLE P2903.1 FBC RES. | | FOR REQUIRED GPM FLOW RATES AND PRESSURES AT FIXTURE | | OUTLET DISCHARGES, AND THE RHEEM RETEX AVERAGE GPM | | USAGE CHART ON PAGE 1 OF THE SPECS- PLEASE SELECT A | | HEATER WITH ADEQUATE CAPACITY. | | | | 2) A5.0: PLEASE NOTE THAT THE DISTANCE FROM THE SHOWER | | TRAP TO THE LAVATORY VENT IN THE MASTER BATH SHALL NOT | | EXCEED 8 FT PER TABLE P3105.1 FBC RES. | | | | 3) A1.0: PLEASE NOTE THAT SHOWER WIDTH IS MEASURED FROM | | THE FINISHED INTERIOR AT A HEIGHT EQUAL TO THE TOP OF | | THE THRESHOLD AND AT A POINT TANGENT TO ITS CENTERLINE | | AND SHALL BE CONTINUED TO A HEIGHT OF NOT LESS THAN 70 | | INCHES ABOVE THE SHOWER DRAIN OUTLET- SECTION P2708.1. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-07-17 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-07-17 |
Time |
15:20 |
Sent To |
|
|
Notes |
2020-07-17 16:53:41 | 1ST REVIEW FBC-2017 RES. | | PERMIT-20050839 | | 7/17/2020 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET A1.0: PROVIDE THE WIDTH OF THE SHOWER IN THE | | COMMON BATHROOM- SECTION P2708.1 FBC RES, AND THE | | FIXTURE CLEARANCE WIDTHS FOR THE TOILETS PER FIGURE | | R307.1 FBC RES. | | | | 2) A5.0: PROVIDE A SHOWER PAN DETAIL- SECTIONS P2709.1 | | & P2709.2 FBC RES. | | | | 3) A5.0: PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR | | THE NEW TANKLESS WATER HEATER AND SUBMIT MANUFACTURER'S | | SPECIFICATIONS- SECTION P2801.3 & TABLE C404.2 FBC EC. | | | | 4) A5.0: PROVIDE A WATER RISER DRAWING SHOWING THE | | PIPING RUNS TO AND FROM THE NEW WATER HEATER, POINTS OF | | CONNECTION TO THE EXISTING SUPPLY PIPES, AND PIPING | | RUNS TO THE NEW FIXTURES- SECTION 107.3.5.3 WPB. PLEASE | | INCLUDE THE SUPPLY LINES TO THE DISHWASHER AND | | REFRIGERATOR ICE MAKER. INDICATE HOW THE DISHWASHER | | SUPPLY LINE WILL BE PROTECTED FROM BACKFLOW PER | | SECTIONS 2717.1 AND 2902.1 FBC RES, AND PROVIDE A WATER | | HAMMER ARRESTOR AND BACKFLOW PREVENTER FOR THE SUPPLY | | LINE TO THE ICE MAKER- SEE SECTIONS P2902.1 AND | | P2903.5. | | | | 5) PROVIDE A SLAB REPAIR DETAIL- SECTION 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
6 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2021-01-14 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2021-01-13 |
Time |
11:26 |
Sent To |
|
|
Notes |
2021-01-14 09:38:18 | FLAT ROOF NOA 20-0110.11 SYSTEM TYPE E(17) ON PAGE 40 | | OF 48. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
5 |
Status |
F |
Date |
2020-12-03 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-12-03 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-12-03 |
Time |
13:29 |
Sent To |
|
|
Notes |
2020-12-03 13:30:38 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | 5TH REVIEW | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PRODUCT APPROVAL FOR THE FLAT DECK ROOFING = PLEASE | | CIRCLE THE ROOFING SYSTEM TO BE USED IN THE PRODUCT | | APPROVAL( SUCH AS (E1, E2, E3 ETC)) - IF NEEDED PLEASE | | PROVIDE SIGNED AND SEALED ADDITIONAL ATTACHMENT DETAILS | | FROM AN ARCHITECT OR ENGINEER FOR THE ROOF ZONES 2 AND | | 3 WHICH MAY REQUIRE A HIGHER WIND PRESSURE - SEE | | GENERAL LIMITATION NUMBER 7 ON THE PRODUCT APPROVAL. | | ---- OR IN WRITING ASK FOR THE ROOFING TO BE A DEFERRED | | PERMIT. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
F |
Date |
2020-11-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-11-13 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-11-13 |
Time |
10:47 |
Sent To |
|
|
Notes |
2020-11-13 10:48:29 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | 4TH REVIEW | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PRODUCT APPROVAL FOR THE FLAT DECK ROOFING = PLEASE | | CIRCLE THE ROOFING SYSTEM TO BE USED IN THE PRODUCT | | APPROVAL( SUCH AS (E1, E2, E3 ETC)) - IF NEEDED PLEASE | | PROVIDE SIGNED AND SEALED ADDITIONAL ATTACHMENT DETAILS | | FROM AN ARCHITECT OR ENGINEER FOR THE ROOF ZONES 2 AND | | 3 WHICH MAY REQUIRE A HIGHER WIND PRESSURE - SEE | | GENERAL LIMITATION NUMBER 7 ON THE PRODUCT APPROVAL. | | ---- OR IN WRITING ASK FOR THE ROOFING TO BE A DEFERRED | | PERMIT. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-29 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-29 |
Time |
12:18 |
Sent To |
|
|
Notes |
2020-10-29 12:34:19 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PRODUCT APPROVAL FOR THE FLAT DECK ROOFING = PLEASE | | CIRCLE THE ROOFING SYSTEM TO BE USED IN THE PRODUCT | | APPROVAL( SUCH AS (E1, E2, E3 ETC)) - IF NEEDED PLEASE | | PROVIDE SIGNED AND SEALED ADDITIONAL ATTACHMENT DETAILS | | FROM AN ARCHITECT OR ENGINEER FOR THE ROOF ZONES 2 AND | | 3 WHICH MAY REQUIRE A HIGHER WIND PRESSURE - SEE | | GENERAL LIMITATION NUMBER 7 ON THE PRODUCT APPROVAL. | | ---- OR IN WRITING ASK FOR THE ROOFING TO BE A DEFERRED | | PERMIT. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2020-09-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-15 |
Time |
14:57 |
Sent To |
|
|
Notes |
2020-09-15 14:57:53 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-22 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-22 |
Time |
12:41 |
Sent To |
|
|
Notes |
2020-07-22 12:41:50 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-10-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-10-29 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-10-29 |
Time |
12:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-09-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-09-15 |
Time |
15:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-07-06 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-07-06 |
Time |
15:45 |
Sent To |
|
|
Notes |
2020-07-06 15:45:42 | PLANS UPLOADED ARE DIGITALLY SIGNED, PAPER NOT | | NECESSARY | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-09-15 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-09-15 |
Time |
|
Rev Time |
0.00 |
Received By |
rthermid |
Date |
2020-09-15 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-08-05 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-08-05 |
Time |
|
Sent To |
I |
|
Notes |
2020-08-05 11:38:14 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 8/5/2020 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PLEASE PROVIDE A MARKED SURVEY OF THE PROPERTY | | INDICATING THE SETBACKS TO THE PROPERTY LINES OF THE | | ADDITION | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | IF THE FORM IS TEMPORARILY UNAVAILABLE, PLEASE REQUEST | | THAT IT BE SENT TO YOU BY EMAILING [email protected] | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | TTY: 800.955.8771 | | E: [email protected] | | W: WPB.ORG |
|
|