Plan Review Details - Permit 20050786
Plan Review Stops For Permit 20050786 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2020-05-27 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-05-27 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-05-27 |
Time |
08:16 |
Sent To |
|
|
Notes |
2020-05-27 08:17:15 | WORK BEING DONE ON ALL UNITS MAIN ADDRESS TO REMAIN |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-05-26 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2020-05-26 |
Time |
|
Sent To |
|
|
Notes |
2020-05-26 11:53:31 | PLEASE EMAIL [email protected], INDICATING WHICH UNIT THE | | WORK IS BEING DONE ON. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-03 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-03 |
Time |
15:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-05-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-05-28 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-05-28 |
Time |
10:00 |
Sent To |
|
|
Notes |
2020-05-28 10:09:13 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) INDICATE THE SYSTEM NUMBER AND THE MAXIMUM DESIGN | | PRESSURE FROM THE TABLES IN THE MODIFIED BITUMEN | | ROOFING PRODUCT APPROVAL. IF THE MAXIMUM DESIGN | | PRESSURE IS LESS THAN REQUIRED FOR THE PERIMETER AND | | CORNER AREAS IN EXPOSURE C IN A 170 MPH WINDSPEED | | (-95.7PSF FOR 15' MRH), THEN YOU WILL HAVE TO SUBMIT | | SIGNED AND SEALED ENHANCED FASTENING CALCULATIONS. FBC | | 107.2.1 | | | | 2) INDICATE THE MINIMUM ATTACHMENT RESISTANCE FOR THE | | ROOF TILE BY MARKING THE APPLICABLE ITEMS IN TABLE 5 OR | | 6 OF THE PRODUCT APPROVAL. FBC 107.2.1 | | | | 3) MARK THE APPLICABLE TILE PROFILE AND ADHESIVE | | PLACEMENT DETAIL ON THE TILE ADHESIVE PRODUCT APPROVAL. | | FBC 107.2.1 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-06-04 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-06-04 |
Time |
12:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-01 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-06-01 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-06-01 |
Time |
13:16 |
Sent To |
|
|
Notes |
2020-06-01 13:16:40 | BARREL TILE TO BE UTILIZED PER OWNER CONFIRMATION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-06-08 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2020-06-08 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2020-06-03 |
Time |
10:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-06-03 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-05-26 |
Time |
13:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-05-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-05-28 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-05-28 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
|