Plan Review Details - Permit 20050732
Plan Review Stops For Permit 20050732
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2020-06-19 Cont ID  
Sent By shill Date 2020-06-19 Time 07:37 Rev Time 0.00
Received By shill Date 2020-06-19 Time 07:37 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2020-06-18 Cont ID  
Sent By shill Date 2020-06-18 Time 15:59 Rev Time 0.00
Received By shill Date 2020-06-18 Time 15:59 Sent To  
Notes
2020-06-18 15:59:51LETTER RECEIVED HAS LANGUAGE NOT CONSISTENT WITH THE
 ACKNOWLEDGEMENT REQUESTED IN PREVIOUS PLAN REVIEW,
 REQUESTED THAT IT BE REVISED

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-06-10 Cont ID  
Sent By jwitmer Date 2020-06-10 Time 08:28 Rev Time 0.00
Received By jwitmer Date 2020-06-10 Time 06:56 Sent To  
Notes
2020-06-10 08:29:43PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-07-28 Cont ID  
Sent By jwitmer Date 2020-07-28 Time 15:14 Rev Time 0.00
Received By jwitmer Date 2020-07-28 Time 14:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-14 Cont ID  
Sent By jwitmer Date 2020-07-14 Time 10:49 Rev Time 0.00
Received By jwitmer Date 2020-07-14 Time 10:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-10 Cont ID  
Sent By jwitmer Date 2020-06-10 Time 08:28 Rev Time 0.00
Received By jwitmer Date 2020-06-10 Time 06:56 Sent To  
Notes
2020-06-10 08:28:052017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050732
 ADD: 1540 PALM BEACH LAKES BLVD. # 130
 CONT: PHILIP E. JOHNSON INC.
 TEL: 561-366-1034
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JUNE 10TH/ 2020
 ACTION: DENIED
  
 1) SHEET 1.1:
  
 1A) SHEET 1.1 UNDER THE HEADING OF PROJECT DATA LIST
 THE FLOOR AREA OF 1,716 SQ. FT. BUT THE OCCUPANT LOAD
 OF 46 IS TAKEN ON 609 SQ. FT. PLEASE PROVIDE THE
 OCCUPANT LOAD FOR THE WHOLE FLOOR AREA. THE FLOOR AREA
 SHOULD BE TAKEN ON A NET SQUARE FOOTAGE. 2017 FBC-B
 TABLE 1004.1.2 AND DEFINITION OF NET FLOOR AREA. 2017
 FBC-B 201: FLOOR AREA, NET. THE ACTUAL OCCUPIED AREA
 NOT INCLUDING UNOCCUPIED ACCESSORY AREAS SUCH AS
 CORRIDORS, STAIRWAYS, TOILET ROOMS, MECHANICAL ROOMS
 AND CLOSETS.
  
 1B) THE FLOOR PLAN HAS NOTES ON THE PLAN THAT THE PLAN
 WAS DESIGNED UNDER BOTH THE PRESCRIPTIVE METHOD AND
 LEVEL II WORK AREA METHOD OF COMPLIANCE. PLEASE REVIEW
 IN THE 2017 EXISTING BUILDING CODE SECTION 301.1 THE
 REPAIRS, ALTERATIONS, CHANGE OF OCCUPANCY, ADDITIONS,
 OR RELOCATION OF ALL EXISTING BUILDINGS SHALL COMPLY
 WITH ONE OF THE METHODS LISTED IN SECTIONS 301.1
 THROUGH 301.1.3 AS SELECTED BY THE DESIGNER OF RECORD.
 SECTIONS 301.1.1 THROUGH 301.1.3 SHALL NOT BE APPLIED
 IN COMBINATION WITH EACH OTHER. PLEASE CHOOSE ONE
 METHOD OF DESIGN.
  
 1C) PLEASE ALSO NOTE WITH THE REAR PORTION OF THE FLOOR
 NOT BEING A POURED CONCRETE FLOOR JUST LEFT DIRT IT
 WOULD APPEAR THIS UNIT WAS LEFT TO BE CONSIDERED A
 VANILLA SHELL, NO OCCUPANCY TYPE. WITH THE NEW PROPOSED
 OCCUPANCY A CHANGE OF OCCUPANCY A WELL. 107.2.1.2.
 ADDITIONAL INFORMATION IS REQUIRED.
  
 1D) THERE IS ALSO A NOTE ON THE PLAN, ADA COMPLIANCE OF
 A226/ A902 REQUIRING HANDICAPPED SEATING W/ CLEARANCES
 PER A306. SEE PLAN FOR DEDICATED TABLES. THIS PLAN DOES
 NOT SHOW ACCESSIBLE SEATING AT ALL. 2017 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATION 107.2.1.
 W.P.B. ADMINISTRATIVE CODE/2017 DRAWINGS &
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO
 THE TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR
 IN PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED
 AS A SUBSTITUTE FOR SPECIFIC INFORMATION". CONSTRUCTION
 DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND
 SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS
 OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 THIS SHEET DOES NOT SHOW COMPLIANCE WITH THE 2017
 FBC-ACCESSIBILITY CODE;
 1E)) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902.
  
 1F) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES
 REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED
 THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING
 SURFACES AND WORK SURFACES.
  
 1G) 206.2.5 206.2.5 RESTAURANTS AND CAFETERIAS. IN
 RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE SHALL
 BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED OR
 SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS.
  
 1H) 902.1 .DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL.
 DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS,
 TABLES, LUNCH COUNTER (HIGH TOPS), AND BOOTHS. EXAMPLES
 OF WORK SURFACES INCLUDE WRITING SURFACES, STUDY
 CARRELS, STUDENT LABORATORY STATIONS, BABY CHANGING AND
 OTHER TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON
 COUNTERS, AND WHERE COVERED BY THE ADA SCOPING
 PROVISIONS, EMPLOYEE WORK STATIONS.
  
 1H)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 1H)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 1I) SHEET 1.1 UNDER THE HEADING TOILET ACCESSORY
 SCHEDULE SHOWS:
  
 1I)(1) GB & GB-1 BOTH TAKING THE VERTICAL MEASUREMENT
 FROM CENTERLINE OF THE GRAB BAR TO FINISH FLOOR. 2017
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 1I)(2) THE MEASUREMENT FOR THE PLACEMENT OF THE TOILET
 PAPER TAKEN FROM THE BACK WALL 36 INCHES FROM THE REAR
 CORNER. . 2017 ACCESSIBILITY CODE SECTION 604.7. TOILET
 PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND SHALL BE
 7-9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET
 MEASURED TO THE CENTER LINE OF THE DISPENSER. THE
 OUTLET OF THE DISPENSER SHALL BE 15 INCHES MINIMUM AND
 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL NOT
 BE LOCATED BEHIND THE GRAB BARS.
  
 1J) UNDER THE HEADING PROJECT DATA THE PLAN DOES NOT
 INCLUDE IN THE 2017 FBC-B 2902.1 MINIMUM NUMBER OF
 FIXTURES NOR 2902.1.1 FIXTURE CALCULATIONS, AND TABLE
 2902.1.
  
 1K) THE PLAN IS SILENT AS TO THE REQUIRED EXIT
 HARDWARE, PLEASE REVIEW IN THE 2017 FBC-B SECTION
 1010.1.10 PANIC HARDWARE WHEN THERE IS AN OCCUPANT LOAD
 OF 50 OR MORE IN GROUP A OCCUPANCIES.
  
 1L) PLEASE ALSO UPDATE THE PLAN NOW 2 MEANS OF EGRESS
 ARE REQUIRED WITH AN OCCUPANT LOAD OF 50 OR MORE. SEE
 TABLE 1006.2.1.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-07-31 Cont ID  
Sent By jleahy Date 2020-07-31 Time 10:35 Rev Time 0.00
Received By jleahy Date 2020-07-31 Time 10:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-06-18 Cont ID  
Sent By jleahy Date 2020-06-18 Time 13:25 Rev Time 0.00
Received By jleahy Date 2020-06-18 Time 13:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-07-31 Cont ID  
Sent By bwoods Date 2020-07-31 Time   Rev Time 0.00
Received By bwoods Date 2020-07-31 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-07-15 Cont ID  
Sent By bwoods Date 2020-07-15 Time   Rev Time 0.00
Received By bwoods Date 2020-07-15 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-07-01 Cont ID  
Sent By bwoods Date 2020-07-01 Time   Rev Time  
Received By bwoods Date 2020-07-01 Time   Sent To  
Notes
2020-07-01 13:37:57PERMIT #20050732
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1.SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
 2.FOR ASSEMBLY AND EDUCATIONAL OCCUPANCIES WITH AN
 OCCUPANT LOAD OF 100 OR MORE PERSONS (50 PERSONS PER
 THE FLORIDA BUILDING CODE), PANIC HARDWARE SHALL BE
 PROVIDED ON DOORS TO RELEASE THE LOCK/LATCH. NO OTHER
 LOCKS OR LATCHES ARE PERMITTED THAT WOULD NOT BE
 RELEASED BY THE PANIC HARDWARE.
 3. INDICATE THE BREAKDOWN OF THE OCCUPANT LOAD OF THE
 OCCUPPIED FLOOR AREA
 IE. BAR AREA
 IE. CUSTOMER AREA
  
 BRITTANY WOODS
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4754
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-07-31 Cont ID  
Sent By shill Date 2020-07-31 Time 13:53 Rev Time 0.00
Received By shill Date 2020-07-24 Time 10:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-07-20 Time   Rev Time 0.00
Received By lmarchan Date 2020-07-10 Time 09:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-01 Cont ID  
Sent By lmarchan Date 2020-07-01 Time 14:30 Rev Time 0.00
Received By lmarchan Date 2020-06-01 Time 14:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-06-15 Cont ID  
Sent By hmoser Date 2020-06-15 Time 08:46 Rev Time 0.00
Received By hmoser Date 2020-06-15 Time 08:03 Sent To  
Notes
2020-06-15 08:46:37PASS PROVISO
 IF DUCT SMOKE DETECTOR IS INSTALLED REFER TO SECTION
 606.4.1 SUPERVISION FBC (M) 2017
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-07-29 Cont ID  
Sent By ccole Date 2020-07-29 Time 12:52 Rev Time 0.00
Received By ccole Date 2020-07-29 Time 11:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-07-20 Cont ID  
Sent By ccole Date 2020-07-20 Time 16:08 Rev Time 0.00
Received By ccole Date 2020-07-20 Time 13:40 Sent To  
Notes
2020-07-20 16:09:432ND REVIEW FBC-2017 PLUMBING
 PERMIT- 20050732
 7/20/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 COMMENTS REMAINING FROM THE 1ST REVIEW ARE LISTED BELOW
 WITH ADDITONAL NOTES IN CAPITAL LETTERS.
  
 1) SHEET 1.1: PROVIDE A PLUMBING FIXTURE CALCULATION
 SCHEDULE ON THE PLAN- TABLE 403.3 FBC P. SHOW THE
 REQUIRED AND PROVIDED FIXTURES IN THE SCHEDULE. PLEASE
 NOTE A DRINKING FOUNTAIN IS REQUIRED FOR A2
 OCCUPANCIES. REFER TO SECTION 410 FBC P, AND SECTIONS
 211 AND 602 FBC ACC FOR FURTHER INFORMATION AND CODE
 COMPLIANCE REQUIREMENTS. THE PLUMBING FIXTURE
 CALCULATION DOES NOT INDICATE THE REQUIRED DRINKING
 FOUNTAIN. REFER TO SECTION 410.4: THE KAVA BAR IS NOT A
 RESTAURANT THEREFORE SUBSTITUTION OF WATER PROVIDED TO
 CUSTOMERS IN CONTAINERS FREE OF CHARGE DOES NOT MEET
 COMPLIANCE.
  
 REFER TO SECTION 211.1.2 FBC ACC, AND TABLE 404.3 FBC
 P. NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE
 PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 SECTIONS 602.1 ? 602.6, AND ONE SHALL COMPLY WITH
 602.7. SECTION 602.7 REQUIRES THAT SPOUT OUTLETS FOR
 STANDING PERSONS SHALL BE 38 INCHES MINIMUM AND 43
 INCHES MAXIMUM FROM THE FINISHED FLOOR. REVISE THE
 PLANS TO SHOW COMPLIANCE AND PROVIDE THESE DETAILS:
 A) THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR
 FORWARD WHEELCHAIR APPROACH- SECTION 602.2. FBC ACC.
 B) KNEE AND TOE CLEARANCES- SECTION 306.
 C) SPOUT HEIGHT AND SPOUT LOCATION- SECTION 602.4 AND
 602.5.
  
 2) SHEET 1.1: CORRECT THE NOTE AT THE TOILET ROOM
 INDICATING 30"X48" CLEAR FLOOR SPACE AT THE WATER
 CLOSET. CLEARANCE AROUND WATER CLOSETS SHALL BE 60
 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM
 THE REAR WALL- SECTION 604.3.1 FBC ACC. TO AVOID
 CONFUSION IN THE FIELD PLEASE INDICATE THE CLEAR FLOOR
 SPACE FOR THE WATER CLOSET- 60? W X 56? D.
  
 3) SHEET 1.1: THE MOUNTING LOCATIONS AND HEIGHTS SHOWN
 IN THE TOILET ACCESSORY SCHEDULE ARE NOT IN COMPLIANCE
 WITH THE FBC ACC. IN ORDER TO EXPEDITE THE REVIEW
 PLEASE PROVIDE ENLARGED DIMENSIONED DETAILS AND
 ELEVATION VIEWS INDICATING: SEE NOTES BELOW FOR NEW
 SHEET 4.1
 E) HEIGHTS OF THE FRONT RIM OF THE LAVATORY FROM THE
 FINISHED FLOOR- SECTION 606.3 THE HEIGHT OF THE FRONT
 RIM OF THE LAVBATORY SHALL BE 34? FROM THE FINISHED
 FLOOR.
 F) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION
 306. NOT PROVIDED.
 G) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS- SECTION 604.5. GRAB BAR HEIGHT IS SHOWN TO THE
 CENTERLINES OF THE GRAB BARS AND NOT TO THE TOP OF THE
 GRIPPING SURFACES.
 H) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS-
 SECTION 604.6. NOT PROVIDED.
 I) LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS FOR
 PAPER DISPENSERS- SECTION 604.7 THE TOILET PAPER
 DISPENSER SHALL BE INSTALLED 7 INCHES MINIMUM AND 9
 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
 J) HEIGHTS OF THE MIRROR FROM THE FINISHED FLOOR TO THE
 BOTTOM OF THE REFLECTIVE SURFACES- SECTION 603.3.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 8) 4.1: PROVIDE A PLUMBING DEVICE SCHEDULE INDICATING
 MAKES AND MODELS, AND LISTING AND LABELING FOR THE
 MIXING VALVE, REQUIRED WATER HAMMER ARRESTORS, AND
 BACKFLOW PREVENTERS- SECTIONS 604.9, 607.1.2, AND 608.3
 FBC P. SHOW ALL DEVICE LOCATIONS ON THE WATER RISER.
 THE WATTS SD-2 BACKFLOW PREVENTER IS DESIGNED FOR USE
 ON CARBONATED BEVERAGE DISPENSERS. PLEASE REVIEW THE
 SPECS FOR THE DEVICE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-06-25 Cont ID  
Sent By ccole Date 2020-06-25 Time 12:15 Rev Time 0.00
Received By ccole Date 2020-06-25 Time 10:35 Sent To  
Notes
2020-06-25 13:12:031ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20050732
 6/25/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 1.1: PROVIDE A PLUMBING FIXTURE CALCULATION
 SCHEDULE ON THE PLAN- TABLE 403.3 FBC P. SHOW THE
 REQUIRED AND PROVIDED FIXTURES IN THE SCHEDULE. PLEASE
 NOTE A DRINKING FOUNTAIN IS REQUIRED FOR A2
 OCCUPANCIES. REFER TO SECTION 410 FBC P, AND SECTIONS
 211 AND 602 FBC ACC FOR FURTHER INFORMATION AND CODE
 COMPLIANCE REQUIREMENTS.
  
 2) SHEET 1.1: CORRECT THE NOTE AT THE TOILET ROOM
 INDICATING 30"X48" CLEAR FLOOR SPACE AT THE WATER
 CLOSET. CLEARANCE AROUND WATER CLOSETS SHALL BE 60
 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM
 THE REAR WALL- SECTION 604.3.1 FBC ACC.
  
 3) SHEET 1.1: THE MOUNTING LOCATIONS AND HEIGHTS SHOWN
 IN THE TOILET ACCESSORY SCHEDULE ARE NOT IN COMPLIANCE
 WITH THE FBC ACC. IN ORDER TO EXPEDITE THE REVIEW
 PLEASE PROVIDE ENLARGED DIMENSIONED DETAILS AND
 ELEVATION VIEWS INDICATING:
 A) CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER CLOSETS-
 SECTION 604.3 FBC ACC.
 B) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORIES-
 SECTION 606.2
 C) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE WALLS
 OR PARTITIONS- SECTION 604.2.
 D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SECTION 604.4.
 E) HEIGHTS OF THE FRONT RIM OF THE LAVATORY FROM THE
 FINISHED FLOOR- SECTION 606.3
 F) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION
 306.
 G) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS- SECTION 604.5
 H) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS-
 SECTION 604.6.
 I) LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS FOR
 PAPER DISPENSERS- SECTION 604.7
 J) HEIGHTS OF THE MIRROR FROM THE FINISHED FLOOR TO THE
 BOTTOM OF THE REFLECTIVE SURFACES- SECTION 603.3.
  
 4) SHEET 4.1: PROVIDE A PLUMBING FIXTURE SCHEDULE-
 SECTION 406 FBC P.
  
 5) 4.1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE WATER
 HEATER INDICATING MAKE AND MODEL, GALLON SIZE, AND
 EFFICIENCY RATING- SECTION 502.1 FBC P, AND TABLE 404.2
 FBC ACC.
  
 6) 4.1: PROVIDE EQUIPMENT SCHEDULES FOR THE WATER
 RECIRCULATING PUMP, AND THE THERMAL EXPANSION TANK-
 SECTION 607.3 FBC P. EXPAND THE WATER HEATER PIPING
 DIAGRAM TO SHOW THE LOCATIONS AND PIPING CONNECTIONS
 FOR THE RECIRC. PUMP AND EXPANSION TANK- SECTIONS 607.2
 & 607.3 FBC P.
  
 7) 4.1, WATER RISER: SHOW WATER SUPPLY CONNECTIONS TO
 THE ICE MAKER, AND ANY OTHER HARD PIPED BEVERAGE
 DISPENSERS OR EQUIPMENT- SECTION 107.2.1 WPB.
  
 8) 4.1: PROVIDE A PLUMBING DEVICE SCHEDULE INDICATING
 MAKES AND MODELS, AND LISTING AND LABELING FOR THE
 MIXING VALVE, REQUIRED WATER HAMMER ARRESTORS, AND
 BACKFLOW PREVENTERS- SECTIONS 604.9, 607.1.2, AND 608.3
 FBC P. SHOW ALL DEVICE LOCATIONS ON THE WATER RISER.
 9) PLEASE PROVIDE A KITCHEN EQUIPMENT PLAN AND SCHEDULE
 FOR THE KAVA COOKING AND DISPENSING OPERATION- SECTION
 107.2.1 WPB.
  
 10) REFER TO SECTIONS 1003.3.1 AND 1003.3.4 FBC P: A
 GREASE INTERCEPTOR WILL BE REQUIRED FOR THE KAVA BAR.
 PLEASE REVISE THE PLUMBING PLANS TO SHOW THE DRAINAGE
 CONNECTIONS TO THE INTERCEPTOR, PROVIDE SIZING
 CALCULATIONS, AND AN EQUIPMENT SCHEDULE ON THE PLAN.
 PLEASE NOTE THAT A SEPARATE PERMIT WILL BE REQUIRED FOR
 EXTERIOR IN-GROUND INSTALLATIONS- SEC 90-125 CITY OF
 WPB CODE OF ORDINANCES
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
2020-06-25 12:15:40 
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-07-31 Cont ID  
Sent By shill Date 2020-07-31 Time 10:14 Rev Time 0.00
Received By shill Date 2020-07-31 Time 10:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-07-20 Cont ID  
Sent By ccole Date 2020-07-20 Time 16:11 Rev Time 0.00
Received By ccole Date 2020-07-20 Time 16:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-06-25 Cont ID  
Sent By ccole Date 2020-06-25 Time 12:39 Rev Time 0.00
Received By ccole Date 2020-06-25 Time 12:39 Sent To  
Notes
***NONE***