Plan Review Details - Permit 20050707
Plan Review Stops For Permit 20050707
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-07-01 Cont ID  
Sent By jwitmer Date 2020-07-01 Time 09:44 Rev Time 0.00
Received By jwitmer Date 2020-07-01 Time 09:07 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-06-01 Cont ID  
Sent By jwitmer Date 2020-06-01 Time 09:03 Rev Time 0.00
Received By jwitmer Date 2020-06-01 Time 09:01 Sent To  
Notes
2020-06-01 09:05:15ASBESTOS COMMERCIAL.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-01 Cont ID  
Sent By jwitmer Date 2020-07-01 Time 09:44 Rev Time 0.00
Received By jwitmer Date 2020-07-01 Time 09:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-01 Cont ID  
Sent By jwitmer Date 2020-06-01 Time 09:45 Rev Time 0.00
Received By jwitmer Date 2020-06-01 Time 09:02 Sent To  
Notes
2020-06-01 09:38:232017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050707
 ADD: 501 S FLAGLER DR. 12TH FL. COMMON RESTROOMS
 CONT: ANDERSON MOORE CONSTRUCTION
 TEL: 561-348-4805
 E-MAIL: PERMITSAANDJ PERMITS.COM
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JUNE 01/2020
 ACTION: DENIED
  
 1) THE LIFE SAFETY SHEET LS-ALS1.1, CODE ANALYSIS ,
 MEANS OF EGRESS FOR COMMON AREAS STATES AN OCCUPANT
 LOAD IS 99 PERSONS (ENTIRE FLOOR) 1 EXIT REQUIRED, 2
 PROVIDED.
 PLEASE REVIEW IN THE 2017 FBC-B TABLE 1006.3.2(2) ONLY
 B, F,M,& S ARE ALLOWED TO HAVE 1 EXIT ABOVE THE GRADE
 PLANE. ALL OCCUPANCIES 3RD FLOOR AND ABOVE ARE REQUIRED
 2 MEANS OF EGRESS TO GRADE. PLEASE CORRECT THE PLAN.
  
 2) THIS FLOOR PLAN DOES NOT SHOW THE RESTROOMS BEING
 ACCESSIBLE NOR IS THERE ANY STATEMENT SHOWING
 COMPLIANCE WITH THE 2017 FBC-B SECTIONS:
 2902.3.2. LOCATION OF TOILET FACILITIES (ACCESSIBLE) IN
 OCCUPANCIES OTHER THAN MALLS .
 2902.4.1 DIRECTIONAL SIGNAGE.
 2017 ACCESS. CODE SECTIONS:
  
 SIGNAGE 703. 703.1 SIGNS SHALL COMPLY WITH 703. WHERE
 BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER
 ONE SIGN WITH BOTH VISUAL AND TACTILE CHARACTERS, OR
 TWO SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH
 TACTILE CHARACTERS, SHALL BE PROVIDED.
  
 SIGNAGE TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND
 2014 ACCESSIBILITY CODE. 703.4.1 HEIGHT ABOVE FINISH
 FLOOR OR GROUND. TACTILE CHARACTERS ON SIGNS SHALL BE
 LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR
 GROUND SURFACE, MEASURED FROM THE BASELINE OF THE
 LOWEST TACTILE CHARACTER AND 60 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE
 BASELINE OF THE HIGHEST TACTILE CHARACTER.
  
 SIGNAGE. 703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND.
 TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES
 MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE,
 MEASURED FROM THE BASELINE OF THE LOWEST TACTILE
 CHARACTER AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR
 OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE
 HIGHEST TACTILE CHARACTER.
  
 BRAILLE. 703.3. BRAILLE SHALL BE CONTRASTED (GRADE 2)
 AND SHALL COMPLY WITH 703.3 AND 703.4.
  
 BRAILLE. 703.3.2 POSITION. BRAILLE SHALL BE POSITIONED
 BELOW THE CORRESPONDING TEXT. IF THE TEXT IS
 MULTI-LINED, THE BRAILLE SHALL BE BELOW THE ENTIRE
 TEXT. BRAILLE SHALL BE SEPARATED 3/8 INCH MINIMUM FROM
 ANY OTHER TACTILE CHARACTER AND 3/8 INCH MINIMUM FROM
 RAISED BORDERS AND DECORATIVE ELEMENTS.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE
 TO CONTACT ME, MY CELL NUMBER IS 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-06-08 Cont ID  
Sent By jpearson Date 2020-06-08 Time 14:22 Rev Time 0.00
Received By jpearson Date 2020-06-08 Time 13:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-07-01 Cont ID  
Sent By pleduc Date 2020-07-01 Time   Rev Time 0.00
Received By pleduc Date 2020-07-01 Time 12:27 Sent To  
Notes
2020-07-01 12:28:11THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE EXISTING FIRE ALARM SYSTEM DEVICES SHALL BE
 MAINTAINED AND REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM OR DEVICES
 SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-05-22 Cont ID  
Sent By pleduc Date 2020-05-22 Time   Rev Time 0.00
Received By pleduc Date 2020-05-22 Time 13:07 Sent To  
Notes
2020-05-22 13:37:50THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE EXISTING FIRE ALARM SYSTEM DEVICES SHALL BE
 MAINTAINED AND REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM OR DEVICES
 SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-14 Cont ID  
Sent By jesmith Date 2020-07-14 Time 13:16 Rev Time 0.00
Received By jesmith Date 2020-07-14 Time 13:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-25 Cont ID  
Sent By shill Date 2020-06-25 Time 09:14 Rev Time 0.00
Received By shill Date 2020-05-21 Time 13:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-06-02 Cont ID  
Sent By medwards Date 2020-06-02 Time 14:07 Rev Time 0.00
Received By medwards Date 2020-06-02 Time 13:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-07-14 Cont ID  
Sent By jesmith Date 2020-07-14 Time 13:15 Rev Time 0.00
Received By jesmith Date 2020-07-14 Time 13:04 Sent To  
Notes
2020-07-14 13:15:0420050707 505 S FLAGLER DR FL 12
  
 PLUMBING COMMENTS: APPROVED
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-06-25 Cont ID  
Sent By jesmith Date 2020-06-25 Time 09:13 Rev Time 0.00
Received By shill Date 2020-06-22 Time 14:04 Sent To  
Notes
2020-06-25 09:14:20CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 20050707 505 S FLAGLER DR FL 12
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 1. ACCESSIBLE RESTROOMS AS REQUIRED BY FBC ACC CHAPTER
 6 AND FBC PL 404.1 ARE NOT SHOWN. PER WPB FBC 107.2.1,
 PROVIDE FLOOR PLAN IDENTIFYING ACCESSIBLE TOILET
 ROOMS/COMPARTMENTS AND DRINKING FOUNTAINS; PROVIDE PLAN
 VIEW/ELEVATION VIEW DETAILS OF REQUIRED ACCESSIBLE
 FIXTURES TO SHOW COMPLIANCE WITH FBC ACC CHAPTERS 3 AND
 6.
 2. RE: A1.1.1, KEY NOTE 10. PER WPB FBC 107.2.1,
 IDENTIFY ON THE FLOOR PLAN, THE WALL HUNG LAVATORY.
  
 A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT
 THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A
 RESPONSE NARRATIVE ADDRESSING THE PLUMBING COMMENTS
 FROM THE FIRST REVIEW.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
 ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE
 DESIGNER IN ACCORDANCE WITH FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-246-0882 MOBILE
  
 20050707 505 S FLAGLER DR FL 12
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-07-01 Cont ID  
Sent By jwitmer Date 2020-07-01 Time 09:45 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-06-02 Cont ID  
Sent By medwards Date 2020-06-02 Time 14:19 Rev Time 0.00
Received By medwards Date 2020-06-02 Time 14:07 Sent To  
Notes
***NONE***