Plan Review Details - Permit 20050685
Plan Review Stops For Permit 20050685
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-10-28 Cont ID  
Sent By jwitmer Date 2020-10-28 Time 09:45 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-07-23 Cont ID  
Sent By jwitmer Date 2020-07-23 Time 08:43 Rev Time 0.00
Received By jwitmer Date 2020-07-23 Time 08:30 Sent To  
Notes
2020-07-23 08:43:122017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050685
 ADD: 2995 45TH ST. / RACE TRAC
 CONT: ATLAS SIGN HOLDINGS
 TEL: 561-863-6659
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 PERMIT FOR (2) NON-ILLUMINATED AWNINGS / VALUE OF
 $11,937.00. AWNINGS (AH) & (AI).
  
 2ND REVIEW
 DATE: THURS. JULY 23RD/ 2020
 ACTION: DENIED
  
  
 NOTICE *************4X FEE / NOTICE!!!!! FLORIDA
 STATUTE 553.80(2)(B)*****************
  
  
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
 PLEASE NOTE FOR THE 2ND REVIEW THERE HAS BEEN NO
 CHANGES TO THE PLANS AND NO NARRATIVE SUBMITTED AS TO
 WHERE OR WHY CHANGES WERE OR WERE NOT MADE TO THE
 PLANS.
  
 1) THERE ARE SHEETS INCLUDED IN THIS PERMIT PACKAGE
 THAT HAVE NOTHING TO DO WITH THE 2 NON-ILLUMINATED
 AWNINGS, THEY NEED TO BE REMOVED OR BE MARKED VOID NOT
 PART OF THIS PERMIT. 107.2.1.2 ADDITIONAL INFORMATION
 IS REQUIRED.
  
 2) SHEETS S-5 FOR AWNING A-I & SHEET S-6 FOR AWNING A-J
 BOTH SHOW THE STRUCTURAL FRAMEWORK OF THE AWNING BUT
 NOTHING IS INDICATED AS TO THE MATERIAL COVERING IS TO
 BE MADE FROM? FOR THIS REVIEW PURPOSE IT IS SUPPOSED TO
 BE A CLOTH MATERIAL. 2017 FBC-B SECTION 3105.3.4.1.
 MATERIALS. WHEN FABRIC IS USED TO COVER AWNINGS OR
 FABRIC OVER COVERED FRAMES SHALL MEET THE FLAME
 PROPAGATION PERFORMANCE CRITERIA OF NFPA 701 OR HAVE A
 FLAME SPREAD INDEX NOT GREATER THAN 25 WHEN TESTED IN
 ACCORDANCE WITH ASTM E-84 OR UL 723.
  
 3) BOTH SHEETS S5 & S6 BOTH GIVE THE WIND DESIGN
 CRITERIA OF 170 VULT EXPOSURE C BUT THE PLANS DO NOT
 STATE IF THIS IS FOR THE BUILDING OR AWNINGS. PLEASE
 REVIEW THE 2 CODE SECTIONS BELOW FOR BREAKAWAY FABRIC
 OR PERMANENT NON-REMOVALABLE FABRIC.
  
 RIGID AWNINGS. BREAK AWAY FABRIC. FBC-B
 3105.4.2.1.DESIGN. THE WIND DESIGN LOADS FOR ANY FABRIC
 OR MEMBRANE-COVERED STRUCTURE DESIGNED WITH A QUICK
 REMOVAL OR BREAKAWAY MEMBRANE OR FABRIC AT WIND
 VELOCITIES OF 75 MPH, SHALL BE BASED ON THE FOLLOWING
 CRITERIA:
 1) MINIMUM WIND SPEED OF 105 MPH
 2) EXPOSURES B, C, OR D AS DEFINED IN CHAPTER 16.
  
 RIGID AWNING. PERMANENT OR NON-REMOVABLE FABRIC. FBC-B
 3105.4.2.2. THE WIND DESIGN LOADS FOR ANY FABRIC OR
 MEMBRANE COVERED STRUCTURE DESIGNED WITH A PERMANENT OR
 NON-REMOVABLE FABRIC OR MEMBRANE, SHALL BE BASED ON THE
 FOLLOWING CRITERIA:
 1) MINIMUM WIND SPEED VELOCITY AS REQUIRED IN CHAPTER
 16 USING FIGURE 1609.3(3) 150 VULT, CATEGORY 1
 BUILDINGS.
 2) EXPOSURES B, C, OR D AS DEFINED IN CHAPTER 16.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-06-23 Cont ID  
Sent By jwitmer Date 2020-06-23 Time 14:09 Rev Time 0.00
Received By jwitmer Date 2020-06-23 Time 08:16 Sent To  
Notes
2020-06-23 14:09:052017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050685
 ADD: 2995 45TH ST. / RACE TRAC
 CONT: ATLAS SIGN HOLDINGS
 TEL: 561-863-6659
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 PERMIT FOR (2) NON-ILLUMINATED AWNINGS / VALUE OF
 $11,937.00. AWNINGS (AH) & (AI).
  
 1ST REVIEW
 DATE: TUES. JUNE 23RD/ 2020
 ACTION: DENIED
  
 1) THERE ARE SHEETS INCLUDED IN THIS PERMIT PACKAGE
 THAT HAVE NOTHING TO DO WITH THE 2 NON-ILLUMINATED
 AWNINGS, THEY NEED TO BE REMOVED OR BE MARKED VOID NOT
 PART OF THIS PERMIT. 107.2.1.2 ADDITIONAL INFORMATION
 IS REQUIRED.
  
 2) SHEETS S-5 FOR AWNING A-I & SHEET S-6 FOR AWNING A-J
 BOTH SHOW THE STRUCTURAL FRAMEWORK OF THE AWNING BUT
 NOTHING IS INDICATED AS TO THE MATERIAL COVERING IS TO
 BE MADE FROM? FOR THIS REVIEW PURPOSE IT IS SUPPOSED TO
 BE A CLOTH MATERIAL. 2017 FBC-B SECTION 3105.3.4.1.
 MATERIALS. WHEN FABRIC IS USED TO COVER AWNINGS OR
 FABRIC OVER COVERED FRAMES SHALL MEET THE FLAME
 PROPAGATION PERFORMANCE CRITERIA OF NFPA 701 OR HAVE A
 FLAME SPREAD INDEX NOT GREATER THAN 25 WHEN TESTED IN
 ACCORDANCE WITH ASTM E-84 OR UL 723.
  
 3) BOTH SHEETS S5 & S6 BOTH GIVE THE WIND DESIGN
 CRITERIA OF 170 VULT EXPOSURE C BUT THE PLANS DO NOT
 STATE IF THIS IS FOR THE BUILDING OR AWNINGS. PLEASE
 REVIEW THE 2 CODE SECTIONS BELOW FOR BREAKAWAY FABRIC
 OR PERMANENT NON-REMOVALABLE FABRIC.
  
 RIGID AWNINGS. BREAK AWAY FABRIC. FBC-B
 3105.4.2.1.DESIGN. THE WIND DESIGN LOADS FOR ANY FABRIC
 OR MEMBRANE-COVERED STRUCTURE DESIGNED WITH A QUICK
 REMOVAL OR BREAKAWAY MEMBRANE OR FABRIC AT WIND
 VELOCITIES OF 75 MPH, SHALL BE BASED ON THE FOLLOWING
 CRITERIA:
 1) MINIMUM WIND SPEED OF 105 MPH
 2) EXPOSURES B, C, OR D AS DEFINED IN CHAPTER 16.
  
 RIGID AWNING. PERMANENT OR NON-REMOVABLE FABRIC. FBC-B
 3105.4.2.2. THE WIND DESIGN LOADS FOR ANY FABRIC OR
 MEMBRANE COVERED STRUCTURE DESIGNED WITH A PERMANENT OR
 NON-REMOVABLE FABRIC OR MEMBRANE, SHALL BE BASED ON THE
 FOLLOWING CRITERIA:
 1) MINIMUM WIND SPEED VELOCITY AS REQUIRED IN CHAPTER
 16 USING FIGURE 1609.3(3) 150 VULT, CATEGORY 1
 BUILDINGS.
 2) EXPOSURES B, C, OR D AS DEFINED IN CHAPTER 16.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-06-29 Cont ID  
Sent By jleahy Date 2020-06-29 Time 16:42 Rev Time 0.00
Received By jleahy Date 2020-06-29 Time 15:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-11-23 Cont ID  
Sent By ajones Date 2020-11-23 Time 14:53 Rev Time 0.00
Received By ajones Date 2020-10-28 Time 15:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-17 Cont ID  
Sent By ccarvaja Date 2020-08-17 Time 18:03 Rev Time 0.00
Received By ccarvaja Date 2020-07-17 Time 11:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-30 Cont ID  
Sent By lmarchan Date 2020-06-30 Time 15:51 Rev Time 0.00
Received By lmarchan Date 2020-06-11 Time 13:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2020-11-05 Cont ID  
Sent By dbattles Date 2020-11-05 Time 09:08 Rev Time 0.00
Received By dbattles Date 2020-11-05 Time 09:08 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-10-28 Cont ID  
Sent By jwitmer Date 2020-10-28 Time 09:46 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-07-23 Cont ID  
Sent By jwitmer Date 2020-07-23 Time 08:46 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2020-07-23 08:46:422ND SIGNATURE REVIEW. JULY 23RD/ 2020.
 THERE APPEARS TO BE SHEETS WITH NO ONE TAKING
 RESPONSIBILITY FOR THE PLANS, NO TITLE BLOCK, IF
 CONTRACTOR DESIGNED PLANS THEN THEY MUST MEETTHE
 FOLLOWING:
  
 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE
 EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H)
 ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C)
 (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT
 WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE
 CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE.
 THE CONTRACTOR (QUALIFIER) THAT CREATED / DRAWN THE SET
 OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR
 OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME
 AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN
 AND PLANS DRAWN. FOR EACH TRADE THE CONTRACTOR
 RESPONSIBLE FOR THE DESIGN UNDER THE TRADE LICENSED IN
 MUST PRINT THEIR NAME, SIGN THEIR NAME AND LICENSE
 NUMBER, NOTE THESE PLANS APPEAR TO BE DRAWN BY ONE
 INDUVIAL, THEY WOULD HAVE TO BE LICENSED AS A BUILDING,
 ELECTRICAL AND PLUMBING CONTRACTOR TO SUBMIT ALL THESE
 TRADES UNDER ONE SHEET.
  
 THE STRUCTURAL SHEETS ARE SIGNED AND SEALED WITH VALID
 SIGNATURES, BUT WITH UNSIGNED CHANGES AFTER THE LAST
 SIGNATURE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-06-23 Cont ID  
Sent By jwitmer Date 2020-06-23 Time 14:17 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2020-06-23 14:16:32THERE APPEARS TO BE SHEETS WITH NO ONE TAKING
 RESPONSIBILITY FOR THE PLANS, NO TITLE BLOCK, IF
 CONTRACTOR DESIGNED PLANS THEN THEY MUST MEETTHE
 FOLLOWING:
  
 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE
 EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H)
 ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C)
 (BUILDING) REQUIRES THE CONTRACTOR FOR THAT TRADE THAT
 WILL BE LICENSED IN THAT TRADE, WILL ALSO BE THE
 CONTRACTOR THAT DESIGNS THE SYSTEM UNDER THAT TRADE.
 THE CONTRACTOR (QUALIFIER) THAT CREATED / DRAWN THE SET
 OF PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR
 OF THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME
 AND LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN
 AND PLANS DRAWN. FOR EACH TRADE THE CONTRACTOR
 RESPONSIBLE FOR THE DESIGN UNDER THE TRADE LICENSED IN
 MUST PRINT THEIR NAME, SIGN THEIR NAME AND LICENSE
 NUMBER, NOTE THESE PLANS APPEAR TO BE DRAWN BY ONE
 INDUVIAL, THEY WOULD HAVE TO BE LICENSED AS A BUILDING,
 ELECTRICAL AND PLUMBING CONTRACTOR TO SUBMIT ALL THESE
 TRADES UNDER ONE SHEET.
  
 THE STRUCTURAL SHEETS ARE SIGNED AND SEALED WITH VALID
 SIGNATURES, BUT WITH UNSIGNED CHANGES AFTER THE LAST
 SIGNATURE.

Review Stop Z ZONING
Rev No 3 Status P Date 2020-11-23 Cont ID  
Sent By ajones Date 2020-11-23 Time 14:52 Rev Time 0.00
Received By ajones Date 2020-11-23 Time 14:52 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2020-08-17 Cont ID  
Sent By ajones Date 2020-08-17 Time 16:33 Rev Time 0.00
Received By ajones Date 2020-08-17 Time 16:33 Sent To  
Notes
2020-08-17 16:34:488/17/20- FAILED- THE PROPOSED SIGN IS NOT SHOWN ON ANY
 ELEVATIONS ON FILE WITH THE PLANNING AND ZONING
 DIVISION.
  
 ANGELLA VANN, AICP
 [email protected]
 561-822-1441

Review Stop Z ZONING
Rev No 1 Status F Date 2020-06-30 Cont ID  
Sent By avann Date 2020-06-30 Time 15:38 Rev Time 0.00
Received By ajones Date 2020-06-30 Time 15:38 Sent To  
Notes
2020-06-30 15:38:586/30/2020- FAILED- PERMIT DOES NOT MATCH APPROVED SITE
 PLAN ON FILE WITH THE PLANNING DIVISION.
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]