Plan Review Details - Permit 20050650
Plan Review Stops For Permit 20050650 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-06-02 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-06-02 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-05-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-05-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-05-26 |
Time |
11:13 |
Sent To |
|
|
Notes |
2020-05-26 11:19:12 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) TEST AS APPLICABLE PER NFPA 13, INCLUDING ANY | | EXISTING DEVICES PER FIRE INSPECTOR TO ENSURE | | FUNCTIONALILITY. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-06-02 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-05-21 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-02 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-02 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-06-02 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-06-02 |
Time |
09:19 |
Sent To |
|
|
Notes |
2020-06-02 09:19:53 | ADVISED ENGINEER REGARDING FUTURE SUBMITTALS, CANNOT | | SELF CERTIFY | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-06-02 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-06-02 |
Time |
08:54 |
Sent To |
|
|
Notes |
2020-06-02 08:56:35 | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | | | THE PLANS HAVE THE TITLE BLOCK OF E&C ENGINEERS | | (EDUARDO SAMOUR, PE) AS WELL AS THE IMAGE OF HIS SEAL, | | BUT LACKS A DIGITAL SIGNATURE. | | | | SINCE THIS ENGINEER HAS A DIGITAL SIGNATURE, PLEASE | | EMAIL A DIGITALLY SIGNED PDF WITH ALL PAGES DIRECTLY TO | | ME. | | |
|
|
|