Plan Review Details - Permit 20050605
Plan Review Stops For Permit 20050605
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-26 Cont ID  
Sent By rmcdouga Date 2020-08-26 Time 07:54 Rev Time 0.00
Received By rmcdouga Date 2020-08-26 Time 07:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-07-16 Cont ID  
Sent By rmcdouga Date 2020-07-16 Time 12:13 Rev Time 0.00
Received By rmcdouga Date 2020-07-16 Time 10:54 Sent To  
Notes
2020-07-16 12:37:54PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PROVIDE AN ELEVATION OF THE BUILDING THAT SHOWS THE
 LOCATION OF THESE DOORS. FBC 107.2.1
  
 2) THE CONDOMINIUM BUILDINGS AT THIS ADDRESS ARE
 MID-RISE BUILDINGS. PROVIDE THE REQUIRED COMPONENT AND
 CLADDING WIND LOAD PRESSURES FOR THE DOOR OPENING.
 SPECIFY THE WIND SPEED, EXPOSURE CATEGORY AND WALL
 ZONE. SPECIFY THE HEIGHT OF THE BUILDING. FBC 107.2.1 &
 1603.1.4
  
 3) HI-LIGHT OR CIRCLE THE APPROPRIATE DOOR TYPE, DESIGN
 PRESSURES AND OTHER ITEMS RELATED TO THE DOORS BEING
 INSTALLED. FBC 107.2.1

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-26 Cont ID  
Sent By rmcdouga Date 2020-08-26 Time 07:54 Rev Time 0.00
Received By rmcdouga Date 2020-08-17 Time 13:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-07-16 Cont ID  
Sent By rmcdouga Date 2020-07-16 Time 12:14 Rev Time 0.00
Received By rmcdouga Date 2020-07-10 Time 16:06 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-08-26 Cont ID  
Sent By rmcdouga Date 2020-08-26 Time 07:54 Rev Time 0.00
Received By rmcdouga Date 2020-08-26 Time 07:54 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-07-16 Cont ID  
Sent By rmcdouga Date 2020-07-16 Time 12:13 Rev Time 0.00
Received By rmcdouga Date 2020-07-16 Time 10:54 Sent To  
Notes
2020-07-16 12:18:23AN ENGINEER WILL BE REQUIRED TO DIGITALLY SIGN THE WIND
 LOAD CALCULATIONS IF SUBMITTED ELECTRONICALLY.
 ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE
 THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE
 THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER
 VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE
 BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER
 DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE
 ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS
 REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER
 FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 &
 61G15
  
  