Plan Review Details - Permit 20050572
Plan Review Stops For Permit 20050572 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2020-05-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-05-26 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-05-26 |
Time |
13:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-04 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-04 |
Time |
16:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-06 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-06 |
Time |
13:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-04 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-04 |
Time |
13:39 |
Sent To |
|
|
Notes |
2020-06-04 15:06:33 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20050572 | | | | CODES IN EFFECT: | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE SPEC SHEETS FOR THE RV61 REGULATOR. | | SHOW THAT THIS REGULATOR MEETS ANSI Z21.80. FBC RES | | G2421.1 | | | | 2) EXISTING REGULATOR AT THE METER IS A LOW PRESSURE | | REGULATOR. THE ?? GALV. UTILITY RISERS MUST BE SIZED TO | | CARRY THE EXISTING LOAD AND THE ADDITIONAL LOAD OF THE | | GENERATOR. PLEASE PROVIDE THE TABLE USED TO SIZE THIS | | AREA. THE NEW LOAD FOR THE PIPING IS 802,000 BTU?S. FBC | | RES G2421.4 | | | | 3) PLEASE PROVIDE THE LENGTH OF POLY UNDERGROUND | | PIPING. FBC FS 107.2.1 | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-06 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-22 |
Time |
14:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-04 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-19 |
Time |
16:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-06 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-06 |
Time |
13:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-04 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-04 |
Time |
15:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-06 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-06 |
Time |
13:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-05-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-05-26 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-05-26 |
Time |
13:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-05-27 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-05-27 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-05-27 |
Time |
|
Sent To |
I |
|
Notes |
2020-05-27 15:48:03 | MECHANICAL EQUIPMENT TO BE AT LEAST 4 FEET FROM | | PROPERTY LINE |
|
|
|
Account Summary | Usage Policy | Privacy Policy