Plan Review Details - Permit 20050572
Plan Review Stops For Permit 20050572
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-05-26 Cont ID  
Sent By rmcdouga Date 2020-05-26 Time 13:24 Rev Time 0.00
Received By rmcdouga Date 2020-05-26 Time 13:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-06-04 Cont ID  
Sent By cthroop Date 2020-06-04 Time 16:23 Rev Time 0.00
Received By cthroop Date 2020-06-04 Time 16:11 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-07-06 Cont ID  
Sent By cthroop Date 2020-07-06 Time 14:15 Rev Time 0.00
Received By cthroop Date 2020-07-06 Time 13:20 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-06-04 Cont ID  
Sent By medwards Date 2020-06-04 Time 15:05 Rev Time 0.00
Received By medwards Date 2020-06-04 Time 13:39 Sent To  
Notes
2020-06-04 15:06:331ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20050572
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE SPEC SHEETS FOR THE RV61 REGULATOR.
 SHOW THAT THIS REGULATOR MEETS ANSI Z21.80. FBC RES
 G2421.1
  
 2) EXISTING REGULATOR AT THE METER IS A LOW PRESSURE
 REGULATOR. THE ?? GALV. UTILITY RISERS MUST BE SIZED TO
 CARRY THE EXISTING LOAD AND THE ADDITIONAL LOAD OF THE
 GENERATOR. PLEASE PROVIDE THE TABLE USED TO SIZE THIS
 AREA. THE NEW LOAD FOR THE PIPING IS 802,000 BTU?S. FBC
 RES G2421.4
  
 3) PLEASE PROVIDE THE LENGTH OF POLY UNDERGROUND
 PIPING. FBC FS 107.2.1
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-06 Cont ID  
Sent By cthroop Date 2020-07-06 Time 14:15 Rev Time 0.00
Received By cthroop Date 2020-06-22 Time 14:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-04 Cont ID  
Sent By cthroop Date 2020-06-04 Time 16:23 Rev Time 0.00
Received By cthroop Date 2020-05-19 Time 16:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-07-06 Cont ID  
Sent By cthroop Date 2020-07-06 Time 14:10 Rev Time 0.00
Received By cthroop Date 2020-07-06 Time 13:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-06-04 Cont ID  
Sent By medwards Date 2020-06-04 Time 15:07 Rev Time 0.00
Received By medwards Date 2020-06-04 Time 15:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-07-06 Cont ID  
Sent By cthroop Date 2020-07-06 Time 14:10 Rev Time 0.00
Received By cthroop Date 2020-07-06 Time 13:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-05-26 Cont ID  
Sent By rmcdouga Date 2020-05-26 Time 13:24 Rev Time 0.00
Received By rmcdouga Date 2020-05-26 Time 13:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-05-27 Cont ID  
Sent By rthermid Date 2020-05-27 Time   Rev Time  
Received By rthermid Date 2020-05-27 Time   Sent To I
Notes
2020-05-27 15:48:03MECHANICAL EQUIPMENT TO BE AT LEAST 4 FEET FROM
 PROPERTY LINE