Plan Review Details - Permit 20050544
Plan Review Stops For Permit 20050544 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-03 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-03 |
Time |
09:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-05-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-21 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-21 |
Time |
09:17 |
Sent To |
|
|
Notes |
2020-05-21 09:55:57 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT | | APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED | | ATTACHMENT DETAILS AND FASTENER TESTING FROM AN | | ARCHITECT OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH | | REQUIRE A HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE | | PRODUCT APPROVAL (-60) - SEE NOTE NUMBER 9 (ADDITIONAL | | ATTACHMENTS) AND NOTE NUMBER 11 (FASTENER TESTING) ON | | THE PRODUCT APPROVAL. SIGNED AND SEALED DRAWINGS OR | | DOCUMENTS WILL NEED TO BE DIGITALLY SIGNED AND SEALED | | TO BE USED IN ELECTRONIC PLAN REVIEW. SHOW THE WIND | | DESIGN DATA USED PER 2017 FBC AND ASCE 7-10 - WIND | | SPEED - EXPOSURE - RISK CATEGORY - ETC. | | | | FYI = ENGINEER CANNOT SELF-CERTIFY THE DIGITAL | | SIGNATURE | | 668.003(2) AND (3), F.S. | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL HAVE | | THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | AUTHORITY. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-03 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-03 |
Time |
09:06 |
Sent To |
|
|
Notes |
2020-06-03 08:25:00 | ROUTED TO PV DESK TO UPLOAD TO PROJECTDOX AND REVIEW | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-05-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-21 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-18 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-03 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-03 |
Time |
09:06 |
Sent To |
|
|
Notes |
2020-06-03 09:15:41 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | SIGNATURE REVIEW APPROVED: | | | | THE CONTRACTOR PROVIDED ORIGINAL (PAPER) ENGINEER'S | | SIGNED/SEALED FASTENER SPACING LETTER. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-05-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-21 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-21 |
Time |
10:04 |
Sent To |
|
|
Notes |
2020-05-21 10:14:06 | SEE BUILDING PLAN REVIEW |
|
|
|