Plan Review Details - Permit 20050511
Plan Review Stops For Permit 20050511 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-07-22 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-07-22 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-06-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-10 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-10 |
Time |
08:03 |
Sent To |
|
|
Notes |
2020-06-10 09:19:41 | PLAN | | REVIEW COMMENTS | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE APPLICATION STATES THAT THIS WILL BE A RE-COVER | | RATHER THAN A TEAR OFF. IN ORDER TO DO A RE-COVER THERE | | CAN BE ONLY ONE EXISTING ROOF COVERING AND IT HAS TO BE | | IN GOOD ENOUGH CONDITION TO RECOVER. THE EXISTING ROOF | | WILL HAVE TO BE INSPECTED AND APPROVED BY THE BUILDING | | DEPARTMENT BEFORE IT CAN BE COVERED. FBC 107 | | | | 2) THE ROOFING SYSTEM ON PAGE 65 OF NOA NO. 15-1020.02, | | IS NOT FOR A WOOD ROOF DECK AND THE DESIGN PRESSURE OF | | -45 PSF IS TOO LOW. THE DESIGN PRESSURE FOR THIS SYSTEM | | HAS LIMITATION #9 AND CAN NOT BE INCREASED BY ENHANCED | | FASTENING. FBC 107 | | | | 3) CIRCLE OR HI-LIGHT THE ROOFING SYSTEM AND DESIGN | | PRESSURE OF THE ONE THAT YOU WILL BE USING. THIS ONE | | STORY BUILDING IS LOCATED IN A 170 MPH VULT WINDSPEED | | AND IS EXPOSURE CATEGORY C. SELECT A SYSTEM THAT HAS A | | DESIGN PRESSURE OF - 95.7 PSF OR MORE OR ONE WITH | | LIMITATION #7 THAT ALLOWS ENHANCED FASTENING | | CALULATIONS. IF USING ENHANCED FASTENING THE | | CALULATIONS ARE REQUIRED TO BE SIGNED AND SEALED. FBC | | R301 | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-03 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-03 |
Time |
15:08 |
Sent To |
|
|
Notes |
2020-06-03 15:09:31 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE APPLICATION STATES THAT THIS WILL BE A RE-COVER | | RATHER THAN A TEAR OFF. IN ORDER TO DO A RE-COVER THERE | | CAN BE ONLY ONE EXISTING ROOF COVERING AND IT HAS TO BE | | IN GOOD ENOUGH CONDITION TO RECOVER. THE EXISTING ROOF | | WILL HAVE TO BE INSPECTED AND APPROVED BY THE BUILDING | | DEPARTMENT BEFORE IT CAN BE COVERED. FBC 107 | | | | 2) THE W-5 SYSTEM THAT YOU HIGHLITED IN THE FL16709 | | PRODUCT APPROVAL IS FOR NEW CONSTRUCTION OR RE-ROOF | | (TEAR OFF). IT IS NOT FOR RECOVER. ALL OF THE RECOVER | | SYSTEMS IN THIS PRODUCT APPROVAL REQUIRE AN INSULATION | | LAYER. FBC 107..2.1 | | | | 3) REGARDLESS OF THE ROOFING SYSTEM THAT YOU SELECT IT | | WILL HAVE TO BE INSTALLED AS SPECIFIED IN THE PRODUCT | | APPROVAL AND THE REQUIRED DESIGN PRESSURES MUST BE MET. | | FBC R301 | | | | 4) THE VALUE OF $3000.00 APPEARS TO BE LOW. SUBMIT A | | COPY OF THE SIGNED CONTRACT. FBC 109.3 | | | | 5) SPECIFY THE AREA OF THE ROOF AND THE ROOF MEAN | | HEIGHT. FBC 107 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-07-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-07-22 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-07-17 |
Time |
11:45 |
Sent To |
I |
|
Notes |
2020-07-17 16:22:12 | ROUTED TO ROOFING BIN |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-06-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-10 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-08 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-03 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-02 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-03 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-03 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
|