Plan Review Stops For Permit 20050502 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-19 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-19 |
Time |
07:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-08-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-03 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-03 |
Time |
14:29 |
Sent To |
|
|
Notes |
2020-08-03 14:36:58 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | COMMENTS FOR THE PREVIOUS REVIEW WERE NOT ADDRESSED. | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | FBC 107 | | 1) THE GENERATOR PAD ENGINEERING THAT WAS SUBMITTED IS | | NOT ACCEPTABLE FOR THE FOLLOWING REASONS: | | A) THE SCHEDULE ON THE DRAWINGS SPECIFIES THE REQUIRED | | MINIMUM WEIGHT FOR THE 22KW GENERATOR AS 466 LBS. AND | | THE SPECIFICATIONS FOR YOUR GENERATOR HAS A WEIGHT OF | | 445 LBS. | | B) THE SCHEDULE ON THE DRAWINGS SPECIFIES THE ALLOWABLE | | WIND LOAD PRESSURES FOR THE GENERATOR, BUT THE REQUIRED | | WIND LOAD PRESSURES FOR THE SITE IT WILL BE INSTALLED | | ARE NOT PROVIDED. SEE GENERAL NOTE #2 ON THE DRAWING | | THAT STATES THAT THE REQUIRED PRESSURES FOR THE SITE OR | | TO BE DETERMINED BY OTHERS. | 2020-08-03 14:31:30 | PLAN REVIEW GENERATOR - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | GENERATOR PAD | | | | 1) STRUCTURAL DETAIL OF THE PRE-CAST GENERATOR PAD | | SHALL HAVE A VALID DIGITAL SIGNATURE OF THE DESIGN | | PROFESSIONAL PER FS 471 & FAC 61G15. | | 2) PROVIDE WIND DESIGN LOADS FOR THE GENERATOR WITH A | | VALID DIGITAL SIGNATURE OF THE DESIGN PROFESSIONAL AS | | REQUIRED FOR THE GENERATOR PAD ENGINEERING PER FBC | | 107.3.5.3 AND R301.2. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-09 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-09 |
Time |
16:13 |
Sent To |
|
|
Notes |
2020-06-09 16:15:09 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT A GENERATOR PAD DRAWING WITH GENERATOR TO PAD | | ANCHORING DETAILS. FBC 107 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-19 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-19 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-19 |
Time |
08:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-07-31 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-07-31 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-07-31 |
Time |
13:24 |
Sent To |
|
|
Notes |
2020-07-31 13:24:15 | 07/31/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEW | | AVAILABLE FROM 6:30 AM TO 7:30 AM / 2:00 PM TO 5:00 PM | | EMAIL: [email protected] CELL: 561-701-6437 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-06-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-17 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-17 |
Time |
12:45 |
Sent To |
|
|
Notes |
2020-06-17 12:47:08 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20050502 | | | | CODES IN EFFECT: | | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THIS IS AN EXISTING GAS METER, I CANNOT REVIEW THIS | | PROJECT UNTIL THE ENTIRE GAS SYSTEM HAS BEEN SUBMITTED. | | PLEASE SUBMIT A LEGIBLE DRAWING SHOWING GAS PRESSURE OF | | THE CURRENT EXISTING GAS SYSTEM, A HOUSE LAYOUT WITH | | THE GAS LINES SHOWN. PLEASE INCLUDE ALL REGULATORS AND | | SHUT OFF VALVES. PROVIDE THE SPECS FOR THE REGULATORS | | USED. PROVIDE PIPE SIZES, TYPE OF MATERIAL USED. PLEASE | | ALSO INCLUDE THE GAS TABLE NUMBER USED FOR EACH TYPE OF | | PIPING IN THIS SYSTEM. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-08-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-19 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-10 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-08-03 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-23 |
Time |
10:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-19 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-19 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-01 |
Time |
16:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-07-31 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-07-31 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-07-31 |
Time |
13:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-06-18 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-18 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-18 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-08-13 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-08-13 |
Time |
14:48 |
Sent To |
|
|
Notes |
2020-08-13 14:48:45 | ENGINEER DRAWING MATCHES ONE UPLOADED TO PROJECTDOX. | | CONCRETE PAD ENGINEERING DRAWING WITH EMBOSSED SEAL AND | | ORIGINAL SIGNATURE SENT TO STORAGE. JG. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-08-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-03 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-08-03 |
Time |
14:27 |
Sent To |
|
|
Notes |
2020-08-03 14:32:22 | PLAN REVIEW GENERATOR - DIGITAL SIGNATURES AND SEALS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1) DESIGN PROFESSIONALS DIGITAL SIGNATURE IS REQUIRED | | ON ELECTRONICALLY SUBMITTED DRAWINGS. FS 471 & FAC | | 61G15 | | | | 2) DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 3) UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | 4) FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | NOTE: YOU MAY PROVIDE A PAPER PLAN WITH WET SIGNATURE | | AND SEAL PRIOR TO PERMIT. | | | | | 2020-08-03 14:31:22 | THE PREFAB GENERATOR PAD DRAWINGS ARE NOT DIGITALLY | | SIGNED BY THE ENGINEER. ELECTRONICALLY SUBMITTED | | DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S DIGITAL | | SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO SUBMIT | | THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. AFTER | | THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT | | THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | DEPARTMENT TO BE VERIFIED. THE ENGINEER'S ORIGINAL | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | PAPER DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | SIGNATURE ARE ACCEPTABLE. FS 471 & 61G15 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-06-18 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-18 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-18 |
Time |
11:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-06-11 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2020-06-11 |
Time |
|
Sent To |
I |
|
Notes |
|
|