Plan Review Stops For Permit 20050500 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-20 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-20 |
Time |
13:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-09 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-09 |
Time |
15:48 |
Sent To |
|
|
Notes |
2020-06-09 15:50:10 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT GENERATOR PAD DRAWINGS WITH GENERATOR TO PAD | | ANCHORING DETAILS. FBC 107 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-18 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-18 |
Time |
14:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2020-06-25 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2020-06-25 |
Time |
07:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-06-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-17 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-17 |
Time |
11:04 |
Sent To |
|
|
Notes |
2020-06-17 11:07:49 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20050500 | | | | CODES IN EFFECT: | | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE GAS PLAN SHOWS AN EXISTING GAS METER, I CANNOT | | REVIEW THIS PROJECT UNTIL THE ENTIRE GAS SYSTEM HAS | | BEEN SUBMITTED. PLEASE SUBMIT A LEGIBLE DRAWING SHOWING | | GAS PRESSURE OF THE CURRENT EXISTING GAS SYSTEM, A | | HOUSE LAYOUT WITH THE GAS LINES SHOWN. PLEASE INCLUDE | | ALL REGULATORS AND SHUT OFF VALVES. PROVIDE THE SPECS | | FOR THE REGULATORS USED. PROVIDE PIPE SIZES, TYPE OF | | MATERIAL USED. PLEASE ALSO INCLUDE THE GAS TABLE NUMBER | | USED FOR EACH TYPE OF PIPING IN THIS SYSTEM. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-20 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-13 |
Time |
10:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-18 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-01 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-06-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-17 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-17 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-07-20 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-07-20 |
Time |
15:49 |
Sent To |
|
|
Notes |
2020-07-20 15:49:48 | PROVISO: MAIL ORIGINAL ENGINEERING TO ME (FPL APPT | | TOMORROW) | | | | SAMANTHA M. HILL | | CHIEF PLANS EXAMINER | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-07-20 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-20 |
Time |
13:00 |
Sent To |
|
|
Notes |
2020-07-20 13:03:01 | THE GENERATOR PAD ENGINEERING IS NOT DIGITALLY SIGNED. | | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | 61G15 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-06-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-17 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-17 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
kalexand |
Date |
2020-06-11 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2020-06-11 |
Time |
|
Sent To |
I |
|
Notes |
|
|