Plan Review Details - Permit 20050421
Plan Review Stops For Permit 20050421 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-05-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-20 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-20 |
Time |
11:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-05-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-18 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-18 |
Time |
10:11 |
Sent To |
|
|
Notes |
2020-05-18 10:21:14 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT | | APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED | | ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR | | ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE | | THAN THE MAXIMUM SHOWN ON THE PRODUCT APPROVAL (-52.5) | | - SEE GENERAL LIMITATION NUMBER 7 ON THE PRODUCT | | APPROVAL. SIGNED AND SEALED DRAWINGS OR DOCUMENTS WILL | | NEED TO BE DIGITALLY SIGNED AND SEALED TO BE USED IN | | ELECTRONIC PLAN REVIEW. | | | | FYI - ENGINEER CANNOT SELF-CERTIFY THE DIGITAL | | SIGNATURE | | 668.003(2) AND (3), F.S. | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL HAVE | | THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | AUTHORITY. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2020-05-19 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-05-19 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-05-19 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-05-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-20 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-20 |
Time |
07:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-05-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-05-19 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-05-14 |
Time |
11:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-05-20 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-05-20 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-05-20 |
Time |
14:42 |
Sent To |
|
|
Notes |
2020-05-20 14:59:37 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | SIGNATURE REVIEW APPROVED: | | | | THE CONTRACTOR PROVIDED ORIGINAL PAPER SIGNED AND | | SEALED DOCUMENT FOR THE BASE SHEET ANCHORING. | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-05-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-20 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-20 |
Time |
11:33 |
Sent To |
|
|
Notes |
2020-05-20 11:37:07 | ENGINEERING PROVIDED NEEDS TO BE DIGITALLY SIGNED AND | | SEALED BY THE ENGINEER. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-05-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-18 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-18 |
Time |
10:21 |
Sent To |
|
|
Notes |
|
|
|