Plan Review Details - Permit 20050388
Plan Review Stops For Permit 20050388
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-06-08 Cont ID  
Sent By rmcdouga Date 2020-06-08 Time 09:42 Rev Time 0.00
Received By rmcdouga Date 2020-06-08 Time 09:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-06-03 Cont ID  
Sent By rmcdouga Date 2020-06-03 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2020-06-03 Time 08:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-05-22 Cont ID  
Sent By rmcdouga Date 2020-05-22 Time 15:30 Rev Time 0.00
Received By rmcdouga Date 2020-05-22 Time 15:30 Sent To  
Notes
2020-05-22 16:28:36PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THIS IS A COMMERCIAL BUILDING AND THE WINDLOAD
 CALCULATIONS THAT WERE SUBMITTED ARE FROM THE FBC
 RESIDENTIAL CODE BOOK. THE WINDLOAD CALCULATIONS ARE
 REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL. FBC 1609
  
 2) THE DEFAULT EXPOSURE CATEGORY IS C FOR THE CITY OF
 WEST PALM BEACH. IF YOU WISH TO USE EXPOSURE B, YOU
 WILL NEED TO SUBMIT AN ANALYSIS FROM A FLORIDA LICENSED
 DESIGN PROFESSIONAL. FBC BUILDING 1609
  
 3) SUBMIT AN ELEVATION DRAWING OF THE THE STOREFRONT
 SYSTEM THAT WILL BE INSTALLED.THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DRAWING IS REQUIRED TO
 BE ON THE DRAWING. FBC 107.2.1.2
  
 4) INDICATE THE SPECIFIC ITEMS, SUCH AS, SIZE AND
 MAXIMUM DESIGN PRESSURE THAT APPLY TO THIS PROJECT IN
 THE STOREFRONT DOOR AND WINDOW PRODUCT APPROVALS. FBC
 107.2.1
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-06-08 Cont ID  
Sent By rmcdouga Date 2020-06-08 Time 09:43 Rev Time 0.00
Received By rmcdouga Date 2020-06-05 Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-06-03 Cont ID  
Sent By rmcdouga Date 2020-06-03 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2020-05-29 Time 08:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-05-22 Cont ID  
Sent By rmcdouga Date 2020-05-22 Time 15:30 Rev Time 0.00
Received By rmcdouga Date 2020-05-18 Time 15:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-06-08 Cont ID  
Sent By rmcdouga Date 2020-06-08 Time 09:42 Rev Time 0.00
Received By rmcdouga Date 2020-06-08 Time 09:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-06-03 Cont ID  
Sent By rmcdouga Date 2020-06-03 Time 08:40 Rev Time 0.00
Received By rmcdouga Date 2020-06-03 Time 08:40 Sent To  
Notes
2020-06-03 08:43:31THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON
 ELECTRONICALLY SUBMITTED DOCUMENTS. THE DRAWINGS AND
 LETTER FROM THE ENGINEER ARE REQUIRED TO HAVE THE
 ENGINEER'S DIGITAL SIGNATURE. FS 471 & FAC 61G15

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-05-22 Cont ID  
Sent By rmcdouga Date 2020-05-22 Time 15:30 Rev Time 0.00
Received By rmcdouga Date 2020-05-22 Time 15:30 Sent To  
Notes
***NONE***