Review Stop G GAS REVIEW
Rev No 1 Status P Date 2020-05-26 Cont ID  
Sent By jpearson Date 2020-05-26 Time 11:31 Rev Time 0.00
Received By jpearson Date 2020-05-26 Time 08:27 Sent To  
Notes
2020-05-26 08:27:35REVIEWED BY JERRY SMITH.
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 20050353 1815 FLORIDA AVE
  
 GAS COMMENTS: APPROVED
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 CITY OF WEST PALM BEACH GAS PIPING AFFIDAVIT OR
 MANOMETER TEST DOCUMENT REQUIRED AT JOBSITE FOR FINAL
 GAS INSPECTION.
 CALL 561-805-6692 FOR FURTHER INFORMATION.
  
 PROVISO
 1. REGARDING LOW PRESSURE PIPING TO POOL HEATER,
 400,000 BTU DEMAND EXCEEDS THAT ALLOWED FOR ? INCH PIPE
 BY TABLE FBC FG 402.4(2). THE REGULATOR AND PIPING FROM
 THE REGULATOR SHALL BE SIZED TO SUPPORT 400,000 BTUS
 AND MAY BE REDUCED TO ACCOMMODATE THE APPLIANCE INLET
 SIZE AT THE INLET WITH USE OF REDUCING FITTINGS AND
 NIPPLE CONFORMING TO FBC FG 403.10.4 (BUSHINGS ARE
 PROHIBITED). PER WPB FBC 107.2.1, MAKE CORRECTION TO
 COMPLY.
 2. REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING
 SHALL BE APPROVED FOR OUTDOOR INSTALLATION PER FBC FG
 410.1. DOCUMENTATION PROVIDED DOES NOT INDICATE SAID
 APPROVAL PER WPB FBC 107.2.1 AND 107.3.4.1, PROVIDE AS
 A DEFERRED SUBMITTAL, THE MANUFACTURER?S SPECIFICATIONS
 FOR THE PRESSURE REGULATORS WHICH SUPPORT THE
 REQUIREMENTS OF FBC FG 410.1. THE DOCUMENTS SHALL BE
 SUBMITTED, APPROVED AND ON SITE PRIOR TO FINAL
 INSPECTION. PROCEED AT YOUR OWN RISK.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-246-0882 MOBILE
  
 20050353 1815 FLORIDA AVE
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-05-26 Time   Rev Time 0.00
Received By jgomez Date 2020-05-12 Time 17:13 Sent To  
Notes
2020-05-18 17:13:21CONVERTED TO DIGITAL. JG.

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-05-26 Cont ID  
Sent By jpearson Date 2020-05-26 Time 11:32 Rev Time 0.00
Received By jpearson Date 2020-05-26 Time 08:28 Sent To  
Notes
2020-05-26 08:27:59REVIEWED BY JERRY SMITH.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-05-18 Cont ID  
Sent By jgomez Date 2020-05-18 Time 17:05 Rev Time 0.00
Received By jgomez Date 2020-05-18 Time 17:05 Sent To  
Notes
2020-05-18 17:16:12NO ARCHITECT OR ENGINEER. JG.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved