Plan Review Stops For Permit 20050265 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-08-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-18 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-18 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-08-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-03 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-03 |
Time |
13:15 |
Sent To |
|
|
Notes |
2020-08-03 13:22:28 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE PREFAB GENERATOR PAD ENGINEERING THAT WAS | | SUBMITTED HAS A REQUIRED MINIMUM WEIGHT OF 466 LBS. FOR | | THE 22KW GENERATOR. THE 22 KW GENERATOR IN THE | | SPECIFICATIONS THAT WERE SUBMITTED HAS A WEIGHT OF 445 | | LBS. THE 445 LBS. GENERATOR DOES NOT MEET THE WEIGHT | | REQUIRED BY THE PAD ENGINEERING. FBC 107 | | | | 2) SEE SIGNATURE REVIEW NOTES. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-06-02 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-06-02 |
Time |
12:02 |
Sent To |
|
|
Notes |
2020-06-02 12:04:05 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT GENERATOR PAD PLANS AND GENERATOR TO PAD | | ANCHORING DETAILS. FBC 107 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-06-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-15 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-15 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2020-06-25 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2020-06-25 |
Time |
08:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-06-10 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-10 |
Time |
17:31 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-10 |
Time |
17:18 |
Sent To |
|
|
Notes |
2020-06-10 17:31:50 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT-20050265 | | | | CODES IN EFFECT: | | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE SPECS FOR THE TYPE OF PIPING USED. | | FBC FS 107.2.1 | | | | 2) PLEASE PROVIDE MODEL NUMBER AND SPECS FOR REGULATOR | | USED. FBC FS 107.2.1 | | | | 3) PLEASE PROVIDE THE SPEC SHEETS FOR THE FLEXIBLE GAS | | LINE HOSE USED TO CONNECT THE GENERATOR. FBC FS 107.2.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-08-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-18 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-10 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-08-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-03 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-07-22 |
Time |
16:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-06-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-15 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-01 |
Time |
16:49 |
Sent To |
|
|
Notes |
2020-06-15 09:02:32 | I DID NOT SEE AN APPLICATION IN THIS PACKAGE. JLEAHY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-05-19 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-05-19 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-05-08 |
Time |
17:51 |
Sent To |
Z |
|
Notes |
2020-05-08 17:51:58 | ROUTED TO ZONING | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-06-10 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-10 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-10 |
Time |
17:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-08-13 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-08-13 |
Time |
14:53 |
Sent To |
|
|
Notes |
2020-08-13 14:53:30 | ENGINEER DRAWING MATCHES ONE UPLOADED TO PROJECTDOX. | | CONCRETE PAD ENGINEERING DRAWING WITH EMBOSSED SEAL AND | | ORIGINAL SIGNATURE SENT TO STORAGE. JG. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-08-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-08-03 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-08-03 |
Time |
13:16 |
Sent To |
|
|
Notes |
2020-08-03 13:25:39 | THE PREFABRICATED GENERATOR PAD ENGINEERING DOES NOT | | HAVE THE ENGINEER'S DIGITAL SIGNATURE. ELECTRONICALLY | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S | | DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO | | SUBMIT THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. | | AFTER THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN | | SUBMIT THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | DEPARTMENT TO BE VERIFIED. THE ENGINEER'S ORIGINAL | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | SIGNATURE ARE ACCEPTABLE. FS 471 & 61G15 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-06-10 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-10 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-06-05 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-06-05 |
Time |
09:30 |
Rev Time |
|
Received By |
rthermid |
Date |
2020-06-05 |
Time |
|
Sent To |
I |
|
Notes |
|
|