Plan Review Stops For Permit 20050214 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-30 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-30 |
Time |
08:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-07-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-21 |
Time |
07:50 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-21 |
Time |
07:49 |
Sent To |
|
|
Notes |
2020-07-21 07:56:58 | GENERATOR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) THE REVISED GENERATOR PAD DRAWING HAS A LIST OF | | GENERATORS AND THEIR WIND DESIGN VALUES - IT DOES NOT | | LIST ANY OF THE GENERATOR MODEL NUMBERS ON THE | | GENERATOR SPEC. SHEET PROVIDED - SO THE WIND DESIGN | | PRESSURES ARE STILL UNKNOWN. PLEASE PROVIDE SIGNED AND | | SEALED GENERATOR SLAB AND TIEDOWN DETAILS FROM AN | | ARCHITECT OR ENGINEER TO COMPLY WITH THE WIND LOADS FBC | | 1609 | | | | FYI = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO | | BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. - OR - | | IF YOUR ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG | | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON | | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW | | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] | | AND ASKING FOR THE FORM. (AT THIS TIME DROP BOX ITEMS | | MAY TAKE 2 TO 3 WEEKS TO PROCESS, TO SEND TO PLAN | | REVIEW - DUE TO LIMITED STAFF INSIDE THE BUILDING | | DEPT.) | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-05-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-27 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-27 |
Time |
16:21 |
Sent To |
|
|
Notes |
2020-05-27 16:43:38 | GENERATOR PAD | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) NEED SIGNED AND SEALED SITE SPECIFIC WIND DESIGN | | PRESSURES FROM AN ARCHITECT OR ENGINEER TO VERIFY WITH | | THE ALLOWABLE WIND PRESSURES SHOWN ON THE PAD | | ENGINEERING (SEE NOTE NUMBER 2 ON THE PROVIDED PAD | | ENGINEERING). | | 2) ALL SIGNED AND SEALED ENGINEERING NEEDS TO BE | | DIGITALLY SIGNED AND SEALED BY THE ENGINEER. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-05-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-05-26 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-05-26 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2020-06-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-11 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-11 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-07-30 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-07-30 |
Time |
07:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-07-21 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-07-06 |
Time |
12:48 |
Sent To |
|
|
Notes |
2020-07-16 12:48:55 | 07/16/2020 RESUBMITTAL UPLOADED TO PROJECT DOX. DRAWING | | WITH ENGINEER'S ORIGINAL SIGNATURE SENT TO "STORAGE". | | JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-11 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-06-11 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-05-11 |
Time |
09:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-06-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-11 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-11 |
Time |
10:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-07-30 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-07-30 |
Time |
12:50 |
Sent To |
|
|
Notes |
2020-07-30 12:51:00 | PROVISO: SUBMIT ORIGINAL ENGINEERING (FPL APPT PENDING) | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-07-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-07-16 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-07-16 |
Time |
12:49 |
Sent To |
|
|
Notes |
2020-07-16 12:49:20 | 07/16/2020 RESUBMITTAL UPLOADED TO PROJECT DOX. DRAWING | | WITH ENGINEER'S ORIGINAL SIGNATURE SENT TO "STORAGE". | | JG. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-05-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-27 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-27 |
Time |
16:43 |
Sent To |
|
|
Notes |
2020-05-27 16:44:39 | ENGINEERING PROVIDED NEEDS TO BE DIGITALLY SIGNED AND | | SEALED BY THE ENGINEER. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
Sent By |
rthermid |
Date |
2020-05-22 |
Time |
|
Rev Time |
|
Received By |
rthermid |
Date |
2020-05-22 |
Time |
|
Sent To |
I |
|
Notes |
|
|