Plan Review Details - Permit 20050210
Plan Review Stops For Permit 20050210
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2020-05-15 Cont ID  
Sent By pvalenti Date 2020-05-15 Time 06:46 Rev Time 0.00
Received By pvalenti Date 2020-05-15 Time 06:13 Sent To  
Notes
2020-05-15 06:47:49PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 NO BUILDING SUBMITTED FOR REVIEW

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2020-05-13 Cont ID  
Sent By jpearson Date 2020-05-13 Time 09:24 Rev Time 0.00
Received By jpearson Date 2020-05-13 Time 09:02 Sent To  
Notes
2020-05-13 09:24:06NO ELECTRICAL SUBMITTED FOR REVIEW.

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-05-20 Cont ID  
Sent By tklarge Date 2020-05-20 Time 09:52 Rev Time 0.00
Received By tklarge Date 2020-05-20 Time 09:36 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-05-18 Cont ID  
Sent By tklarge Date 2020-05-18 Time 08:18 Rev Time 0.00
Received By tklarge Date 2020-05-18 Time 07:30 Sent To  
Notes
2020-05-18 08:18:221) SHOW THE LOCATION OF ALL THE REGULATORS ON THE GAS
 DRAWING.
 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE GAS
 REGULATORS. RREGULATORS INSTALLED ON THE EXTERIOR OF
 BUILDINGS SHALL BE APPROVED FOR OUTDOOR INSTALLATION.
 FBC-FUEL GAS SEC.410.1.
 3 ) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1.
 4) SHOW THE DISTANCE FROM EACH REGULATOR TO THE
 APPLIANCE AND SIZE EACH LINE FROM THE REGULATOR TO THE
 APPLIANCE.
 5) SUBMIT A FLOOR PLAN THAT SHOWS THE DISTANCE OF THE
 TANKLESS WATER HEATERS TO ALL OPERABLE DOORS, WINDOWS
 AND OTHER BUILDING OPENINGS. THE LOCATION OF THE
 TANKLESS WATER HEATERS SHALL COMPLY WITH THE
 MANUFACTURER'S INSTALLATION MANUAL.
 6) NOTE ON THE GAS RISER WHAT SIZING TABLES ARE BEING
 USED FOR THE DESIGN OF THE LOW PRESSURE SYSTEM FOR THE
 CSST AND SCH. 40 PIPE.
  
 NOTE: ACCORDING TO CITY RECORDS, A GAS PLAN REVIEW WAS
 NEVER DONE ON THE MASTER PERMIT AS THERE WAS NO GAS
 DRAWING SUBMITTED.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-05-20 Cont ID  
Sent By tklarge Date 2020-05-20 Time 09:53 Rev Time 0.00
Received By tklarge Date 2020-05-19 Time 10:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-05-18 Cont ID  
Sent By tklarge Date 2020-05-18 Time 08:19 Rev Time 0.00
Received By tklarge Date 2020-05-07 Time 15:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-05-13 Cont ID  
Sent By medwards Date 2020-05-08 Time 12:16 Rev Time 0.00
Received By medwards Date 2020-05-13 Time 10:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-05-20 Cont ID  
Sent By tklarge Date 2020-05-20 Time 09:53 Rev Time 0.00
Received By tklarge Date 2020-05-20 Time 09:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-05-18 Cont ID  
Sent By tklarge Date 2020-05-18 Time 08:18 Rev Time 0.00
Received By tklarge Date 2020-05-18 Time 08:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2020-05-20 Cont ID  
Sent By tklarge Date 2020-05-20 Time 09:53 Rev Time 0.00
Received By tklarge Date 2020-05-20 Time 09:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-05-15 Cont ID  
Sent By pvalenti Date 2020-05-15 Time 06:48 Rev Time 0.00
Received By pvalenti Date 2020-05-15 Time 06:13 Sent To  
Notes
2020-05-15 08:00:16PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 SIGNATURE REVIEW APPROVED:
  
 THE CONTRACTOR PROVIDED SIGNED AND SEALED DRAWINGS. THE
 SIGNED/SEALED DRAWING WAS SENT TO SCANNING.
  
  
  
  