Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-05-13 Cont ID  
Sent By cthroop Date 2020-05-13 Time 16:42 Rev Time 0.00
Received By cthroop Date 2020-05-13 Time 07:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-05-11 Cont ID  
Sent By cthroop Date 2020-05-11 Time 10:28 Rev Time 0.00
Received By cthroop Date 2020-05-11 Time 09:24 Sent To  
Notes
2020-05-11 10:34:58CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 PLAN REVIEW - BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER ? BUILDING - PX3169
 PLANS EXAMINER ? 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A SITE PLAN. IDENTIFY LOCATION OF ALL
 WINDOWS AND EXTERIOR DOORS TO BE REPLACED. OPENING
 IDENTIFIER SHOULD MATCH WINDOW SCHEDULE.
 107.2.5 SITE PLAN.
  
 2. PLACE PROPERTY ADDRESS ON WINDOW SCHEDULE.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. VALUE.
  
 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE
 OF WORK.
  
 2. THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
  
 3. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
  
 4. FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-05-14 Cont ID  
Sent By aborngra Date 2020-05-14 Time 10:47 Rev Time 0.00
Received By aborngra Date 2020-05-14 Time 10:37 Sent To  
Notes
2020-05-14 10:37:53THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITION(S):
  
 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME OPENING AND MATCH THE INSET/DEPTH/LOCATION
 OF THE ORIGINAL WINDOWS WITHIN THE WINDOW FRAME. (THE
 TOP SASH OF THE WINDOWS SHALL NOT BE FLUSH WITH THE
 EXTERIOR WALL)
 2. THE MULLION SHALL REMAIN ON ALL WINDOW OPENINGS OR
 BE REPLACED WITH A MULLION OF THE SAME WIDTH.
 3. ALL STREET FACING GLASS ON THE FRONT STRUCTURE SHALL
 BE CLEAR ONLY. ALL NON-STREET FACING GLASS ON THE FRONT
 STRUCTURE AND ALL GLASS ON THE REAR STRUCTURE MAY HAVE
 CLEAR GLASS OR CLEAR GLASS WITH LOW-E COATING.
 4. ALL WINDOWS ON THE FRONT STRUCTURE SHALL HAVE A 6/6
 LITE PATTERN WITH EXTERNAL OGEE DIMENSIONAL MUNTINS.
 THE REAR STRUCTURE SHALL HAVE A 1/1 LITE PATTERN. FOR
 CGI SENTINEL PRODUCTS, PLEASE USE THE SEMI-CONTOURED
 MUNTIN PROFILE. ALL WINDOWS SHALL HAVE WHITE EXTERNAL
 FRAMES.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2020-05-06 Cont ID  
Sent By aborngra Date 2020-05-06 Time 11:58 Rev Time 0.00
Received By aborngra Date 2020-05-06 Time 11:57 Sent To  
Notes
2020-05-06 11:58:45THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 1. PLEASE RESUBMIT AND FOLLOW THE ATTACHED WINDOW
 PERMIT APPLICATION EXAMPLE. PROVIDE A WINDOW SCHEDULE
 AND PHOTOS OF EACH ELEVATION AND/OR WINDOW/DOOR WITH
 LABELS.
 2. PROVIDE DOOR INFORMATION INCLUDING PRODUCT APPROVAL
 AND THE APPEARANCE OF THE DOORS.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS, SUBJECT TO
 CHANGE:
 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME OPENING AND MATCH THE INSET/DEPTH/LOCATION
 OF THE ORIGINAL WINDOWS WITHIN THE WINDOW FRAME.
 2. THE MULLION SHALL REMAIN ON ALL WINDOW OPENINGS OR
 BE REPLACED WITH A MULLION OF THE SAME WIDTH.
 3. ALL STREET FACING GLASS SHALL BE CLEAR ONLY.
 NON-STREET FACING GLASS MAY HAVE CLEAR OR CLEAR WITH
 LOW-E COATING.
 4. ALL WINDOWS ON THE FRONT STRUCTURE SHALL HAVE A 6/6
 LITE PATTERN WITH EXTERNAL OGEE DIMENSIONAL MUNTINS.
 THE MAIN HOUSE SHALL HAVE A 1/1 LITE PATTERN. FOR CGI
 SENTINEL PRODUCTS, PLEASE USE THE SEMI-CONTOURED MUNTIN
 PROFILE. ALL WINDOWS SHALL HAVE WHITE EXTERNAL FRAMES.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-05-18 Cont ID  
Sent By cthroop Date 2020-05-18 Time 10:19 Rev Time 0.00
Received By cthroop Date 2020-05-11 Time 14:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-05-11 Cont ID  
Sent By cthroop Date 2020-05-11 Time 10:35 Rev Time 0.00
Received By cthroop Date 2020-05-04 Time 11:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-05-11 Cont ID  
Sent By cthroop Date 2020-05-11 Time 10:28 Rev Time 0.00
Received By cthroop Date 2020-05-11 Time 09:24 Sent To  
Notes
***NONE***