Plan Review Details - Permit 20041123
Plan Review Stops For Permit 20041123 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-17 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-17 |
Time |
10:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-06-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-23 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-23 |
Time |
16:04 |
Sent To |
|
|
Notes |
2020-06-23 16:12:13 | PLAN REVIEW - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | ALL DOOR MODELS LISTED ON PRODUCT APPROVAL FL2509-R5 | | ARE NON-IMPACT RATED AND REQUIRE OPENING PROTECTION. | | | | 1. SUBMIT IMPACT RATED DOOR OR SUBMIT SCHEDULE FOR | | OPENING PROTECTION AND PRODUCT APPROVAL OF SHUTTER TO | | BE USED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-02 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-02 |
Time |
11:50 |
Sent To |
|
|
Notes |
2020-06-02 12:22:24 | PLAN REVIEW - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER BUILDING - PX3169 | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | DOOR SUBMITTED FOR REVIEW, AURORA IWP FOLDING DOOR | | REQUIRES IMPACT RESISTANT COVERING. | | | | 1. SUBMIT IMPACT RATED DOOR OR SUBMIT SCHEDULE FOR | | OPENING PROTECTION AND PRODUCT APPROVAL OF SHUTTER TO | | BE USED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-07-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-17 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-17 |
Time |
10:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-06-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-23 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-16 |
Time |
07:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-02 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-20 |
Time |
10:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2020-06-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-23 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-23 |
Time |
16:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-02 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-02 |
Time |
11:50 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy