Plan Review Details - Permit 20041087
Plan Review Stops For Permit 20041087
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-05-26 Cont ID  
Sent By rmcphers Date 2020-05-26 Time 09:31 Rev Time 0.00
Received By rmcphers Date 2020-05-26 Time 09:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-05-26 Cont ID  
Sent By jleahy Date 2020-05-26 Time 14:06 Rev Time 0.00
Received By jleahy Date 2020-05-26 Time 13:54 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-08-24 Cont ID  
Sent By lcrespo Date 2020-08-24 Time 14:33 Rev Time 0.00
Received By lcrespo Date 2020-08-24 Time 14:06 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-06-03 Cont ID  
Sent By medwards Date 2020-06-03 Time 11:54 Rev Time 0.00
Received By medwards Date 2020-06-03 Time 11:30 Sent To  
Notes
2020-06-03 11:58:531ST REVIEW FBC-2017 MECHANICAL
 PERMIT -20041087
  
 CODES IN EFFECT:
  
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE ISOMETRIC DRAWING INDICATES THAT YOU ARE GOING
 TO TEE INTO THE NG METER. PLEASE SHOW EXISTING LOAD ON
 THIS PIPE. SHOW THAT THE EXISTING PIPE CAN SUPPORT THE
 ADDITIONAL LOAD OF THE 330,000 BTU GENERATOR. FBC FG
 401.8
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-08-25 Cont ID  
Sent By cthroop Date 2020-08-25 Time 11:50 Rev Time 0.00
Received By cthroop Date 2020-08-13 Time 15:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-06-16 Cont ID  
Sent By cpuell Date 2020-06-16 Time 11:27 Rev Time 0.00
Received By cpuell Date 2020-05-08 Time 14:41 Sent To Z
Notes
2020-05-08 14:41:40ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-08-24 Cont ID  
Sent By lcrespo Date 2020-08-24 Time 14:33 Rev Time 0.00
Received By lcrespo Date 2020-08-24 Time 14:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-06-03 Cont ID  
Sent By medwards Date 2020-06-03 Time 12:00 Rev Time 0.00
Received By medwards Date 2020-06-03 Time 12:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-05-12 Cont ID  
Sent By pvalenti Date 2020-05-12 Time 14:23 Rev Time 0.00
Received By pvalenti Date 2020-05-12 Time 14:23 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-08-25 Cont ID  
Sent By awooten Date 2020-08-25 Time   Rev Time 0.00
Received By awooten Date 2020-08-25 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-06-16 Cont ID  
Sent By cpuell Date 2020-06-16 Time 11:27 Rev Time  
Received By awooten Date 2020-06-16 Time   Sent To  
Notes
2020-06-16 10:50:42***************ZONING REVIEW FAILED************
  
 PROVIDE THE SETBACK FOR THE GENERATOR ON THE SURVEY.
  
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR
 FEET INTO A SETBACK.*
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]