2020-04-28 19:12:40 | PLAN |
| REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC SIXTH EDITION (2017) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| ELEVATION CERTIFICATE COMMENTS |
| |
| 1) THE LATITUDE AND LONGITUDE SPECIFIED ON THE |
| ELEVATION CERTIFICATE IS NOT CORRECT. THE COORDINATES |
| PROVIDED ARE FOR A POINT OFF THE COAST OF MIAMI. PLEASE |
| CORRECT. FBC 107.1.2 |
| |
| 2) THE COMMENT SECTION SHOULD REFERENCE THE |
| FLOODPROOFING CERTIFICATE. |
| |
| FLOODPROOFING CERTIFICATE COMMENTS |
| |
| 1) THE LAYOUT OF THE REVISED FLOODPROOFING CERTIFICATE |
| THAT WAS SUBMITTED HAS THE MAP INFORMATION FROM THE |
| PREVIOUS FIRM WITH THE BFE SPECIFIED IN NAVD 88. THE |
| CURRENT MAP INFORMATION AND BFE (NAVD 88) SHOULD BE |
| USED IN ORDER TO BE CONSISTANT WITH THE ELEVATION |
| CERTIFICATE. A COPY OF THE FINAL FORM WITH O.M.B. |
| APPROVAL IS REQUIRED. |
| |
| FLOODPROOFING CERTIFICATE FOR NON-RESIDENTIAL |
| STRUCTURES |
| INSTRUCTIONS FOR COMPLETING THE FLOODPROOFING |
| CERTIFICATE FOR NON-RESIDENTIAL STRUCTURES |
| TO RECEIVE CREDIT FOR FLOODPROOFING, A COMPLETED |
| FLOODPROOFING CERTIFICATE FOR NON-RESIDENTIAL |
| STRUCTURES IS REQUIRED FOR NON-RESIDENTIAL AND BUSINESS |
| BUILDINGS IN THE REGULAR PROGRAM COMMUNITIES, LOCATED |
| IN ZONES A1- A30, AE, AR, AR DUAL, AO, AH, AND A WITH |
| BFE. |
| IN ORDER TO ENSURE COMPLIANCE AND PROVIDE REASONABLE |
| ASSURANCE THAT DUE DILIGENCE HAD BEEN APPLIED IN |
| DESIGNING AND CONSTRUCTING FLOODPROOFING MEASURES, THE |
| FOLLOWING INFORMATION MUST BE PROVIDED WITH THE |
| COMPLETED FLOODPROOFING CERTIFICATE: |
| 1- PHOTOGRAPHS OF SHIELDS, GATES, BARRIERS, OR |
| COMPONENTS DESIGNED TO PROVIDE FLOODPROOFING PROTECTION |
| TO THE STRUCTURE. |
| 2- WRITTEN CERTIFICATION THAT ALL PORTIONS OF THE |
| STRUCTURE BELOW THE BFE THAT WILL RENDER IT WATERTIGHT |
| OR SUBSTANTIALLY IMPERMEABLE TO THE |
| PASSAGE OF WATER AND MUST PERFORM IN ACCORDANCE WITH |
| TITLE 44 CODE OF FEDERAL REGULATIONS (44 CFR 60.3 |
| (C)(3)). |
| 3- A COMPREHENSIVE MAINTENANCE PLAN FOR THE ENTIRE |
| STRUCTURE TO INCLUDE BUT NOT LIMITED TO: |
| 4- EXTERIOR ENVELOPE OF THE STRUCTURE |
| 5- ALL PENETRATIONS TO THE EXTERIOR OF THE STRUCTURE |
| 6- ALL SHIELDS, GATES, BARRIERS, OR COMPONENTS DESIGNED |
| TO PROVIDE FLOODPROOFING PROTECTION TO THE STRUCTURE |
| 7- ALL SEALS OR GASKETS FOR SHIELDS, GATES, BARRIERS, |
| OR COMPONENTS |
| 8- LOCATION OF ALL SHIELDS, GATES, BARRIERS, AND |
| COMPONENTS AS WELL AS ALL ASSOCIATED HARDWARE, AND ANY |
| MATERIALS OR |
| SPECIALIZED TOOLS NECESSARY TO SEAL THE STRUCTURE. |