Plan Review Details - Permit 20040821
Plan Review Stops For Permit 20040821 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-05-11 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-05-11 |
Time |
09:29 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2020-04-24 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-04-24 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-04-24 |
Time |
12:36 |
Sent To |
I |
|
Notes |
2020-04-24 12:41:50 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE PROPOSED PROJECT INDICATES THE USE OF FLEX DROP | | PIPING. THE EXISTING SYSTEM APPEARS TO A TYPICAL ARM | | OVER. | | | | THERE IS NO HYDRAULIC CALCULATION SUBMITTED THAT SHOWS | | THAT THE NEW FLEX DROPS WILL BE SUPPORTED BY THE | | EXISTING SYSTEM DESIGN OR A DESIGN PROFESSIONAL | | STATEMENT THAT INDCATES THE HYDRALIC CALCULATIONS SHALL | | NOT BE AFFECTED BY THE INSTALLATION OF THE FLEX DROP. | | AND THAT THE SYTEM/SPRINKLER HEAD SHALL FUNCTION AS | | DESIGNED. | | | | PLEASE PROVIDE CALCULATIONS OR DESIGN PROFESSIONAL | | STATEMENT. | | | | | | | | 2) THERE ARE NO SPEC SHEETS FOR THE TYPE AND/OR SIZE OF | | THE FLEX DROP. | | | | PLEASE PROVIDE SHEETS THAT MATCH THE NEW FLEX DROP. | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-05-11 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-05-11 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-04-30 |
Time |
11:08 |
Sent To |
|
|
Notes |
2020-05-08 11:08:54 | CONVERTED TO DIGITAL. JG. | 2020-05-04 14:42:22 | 05/04/2020 SENT TO TEQUESTA FOR SCANNING. PLANS WILL BE | | UPLOADED TO PROJECTDOX ONCE THEY ARE SCANNED. JG. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-04-27 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2020-04-27 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2020-04-20 |
Time |
14:26 |
Sent To |
|
|
Notes |
2020-04-23 14:27:28 | SENT TO FIRE BIN. JG. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2020-05-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-05-04 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-05-04 |
Time |
14:21 |
Sent To |
|
|
Notes |
2020-05-04 14:21:57 | NO ARCHITECT OR ENGINEER. JG. |
|
|
|