Plan Review Details - Permit 20040480
Plan Review Stops For Permit 20040480 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-05-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-06 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-06 |
Time |
07:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-04-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-15 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-15 |
Time |
09:40 |
Sent To |
|
|
Notes |
2020-04-15 11:14:48 | PLAN REVIEW - BUILDING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE A BUILDING PLAN. IDENTIFY LOCATION OF NEW | | WINDOWS. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 2. PROVIDE DESIGN WIND CALCULATIONS PER FBC R301. | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-R301.2. | | | | 3. PROVIDE WINDOW SCHEDULE WITH ROUGH OPENING | | DEMENSIONS AND DESIGN PRESSURES FOR EACH OPENING. | | OPTION: YOU MAY PLACE R.O. AND D.P. ON PLAN NEXT TO | | EACH OPENING. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-05-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-06 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-27 |
Time |
15:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-04-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-15 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-13 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-05-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-06 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-06 |
Time |
07:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-04-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-15 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-15 |
Time |
09:40 |
Sent To |
|
|
Notes |
2020-04-15 11:16:16 | PLAN REVIEW - DIGITAL SIGNATURES | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NON-DESIGN PROFESSIONALS | | | | 1. THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | TITLE BLOCK AND SIGNATURE ON PLAN SHEETS UNDER THEIR | | AUTHORITY ? | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, SECTION 107.2.1. | | IF THE DESIGNER IS A FLORIDA LICENSED ARCHITECT OR | | ENGINEER, HE/SHE SHALL ALSO PROVIDE AN ORIGINAL SEAL | | AND WET SIGNATURE PER F.S. 61G15-16.003 AND FAC 23.002. | | | | 2. UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL WITH | | SIGNATURE OF DESIGNER AS APPLICABLE; USE THE REQUIRED | | NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | |
|
|
|