Plan Review Stops For Permit 20040291 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-02 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-02 |
Time |
16:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-13 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-13 |
Time |
16:16 |
Sent To |
|
|
Notes |
2020-04-13 16:46:40 | PLAN REVIEW - BUILDING | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE SCHEDULE FOR INSTALLATION OF OPENING | | PROTECTIVE DEVICES. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | PLEASE CONTACT ME AT THE ABOVE E-MAIL AND I WILL SEND | | YOU A COPY OF THE CITY'S SHUTTER SCHEDULE. | | | | 2. DESIGNER SHALL REVIEW AND APPROVE PRODUCT APPROVALS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE SHUTTER, WINDOW AND DOOR | | SUBMITTALS. | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2020-07-28 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-07-28 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-07-28 |
Time |
10:29 |
Sent To |
|
|
Notes |
2020-07-28 10:30:06 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | CONDITION(S): | | 1. CLEAR GLASS ON STREET FACING ELEVATIONS. | | 2. CLEAR GLASS OR CLEAR GLASS WITH LOW-E ON NON-STREET | | FACING ELEVATIONS. | | 3. SECOND-FLOOR OPENINGS SHALL NOT BE REPLACED. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | PLANNING DIVISION | | [email protected] | OFFICE: 561.822.1428 | TTY: | | 800.955.8771 | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | FL 33402 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-07-02 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-07-02 |
Time |
16:55 |
Sent To |
|
|
Notes |
2020-07-02 17:04:23 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | 1. THE FLOOR PLAN DOES NOT ACCURATELY REFLECT THE | | PROPERTY. OPENINGS #19 AND #20 ARE FRENCH DOORS ON THE | | SECOND FLOOR. OPENING #18 IS A 1 SINGLE-HUNG WINDOW ON | | THE SECOND FLOOR. BASED ON CONVERSATIONS THIS IS A | | FIRST FLOOR WINDOW THAT IS PAIRED. | | 2. COMMENTS ADDRESSED SENT IN THE EMAIL ON THURSDAY, | | JUNE 25TH AT 4:48PM WERE NOT ADDRESSED. | | 3. THE PAIRED WINDOWS TO REPLACE APPEAR TO HAVE A 2 | | INCH WIDE MULLION AND THE NEW MULLION WILL NEED TO | | MATCH THE EXISTING WIDTH (MAY EXCEED 2 INCHES). | | 4. INCLUDE THE LAWSON ORDER FORM. | | | | AT THIS TIME, I HAVE THE FOLLOWING PROPOSED | | CONDITION(S): | | | | 1. ALL STREET-FACING GLASS SHALL BE CLEAR ONLY. | | 2. ALL NON-STREET FACING GLASS SHALL HAVE CLEAR GLASS | | OR CLEAR GLASS WITH LOW-E COATING. | | 3. ALL MUNTINS SHALL HAVE AN EXTERNAL DIMENSIONAL OGEE | | PROFILE. | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2020-04-20 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-04-20 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-04-20 |
Time |
11:19 |
Sent To |
|
|
Notes |
2020-04-20 11:20:07 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | 1. A HORIZONTAL ROLLER WINDOW IS INAPPROPRIATE FOR THIS | | STRUCTURE. PLEASE REVISE TO A CASEMENT OR A PAIRED | | CASEMENT. PROVIDE A PHOTO OF THE EXISTING WINDOW. | | 2. PROVIDE DETAILS FOR THE TWO FRENCH DOORS INCLUDING | | LITE PATTERN. PROVIDE A PHOTO OF THE EXISTING DOORS. | | 3. PROVIDE A FLOOR PLAN. THE SKETCH AVAILABLE ON THE | | PROPERTY APPRAISERS WEBSITE WILL BE SUFFICIENT TO MARK | | THE OPENING LOCATIONS. | | | | AT THIS TIME, I HAVE THE FOLLOWING PROPOSED | | CONDITION(S): | | | | 1. ALL STREET-FACING GLASS SHALL BE CLEAR ONLY. | | 2. ALL NON-STREET FACING GLASS SHALL HAVE CLEAR GLASS | | OR CLEAR GLASS WITH LOW-E COATING. | | 3. ALL MUNTINS SHALL HAVE AN EXTERNAL DIMENSIONAL OGEE | | PROFILE. | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-07-06 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-07-02 |
Time |
16:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-22 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-04-07 |
Time |
09:15 |
Sent To |
|
|
Notes |
2020-04-08 09:15:36 | TO PV DESK | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-07-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-02 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-02 |
Time |
16:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-13 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-13 |
Time |
16:16 |
Sent To |
|
|
Notes |
2020-04-13 16:49:52 | PLAN REVIEW - DIGITAL SIGNATURES | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NON-DESIGN PROFESSIONALS | | | | 1. THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | TITLE BLOCK AND SIGNATURE ON PLAN SHEETS UNDER THEIR | | AUTHORITY ? | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, SECTION 107.2.1. | | IF THE DESIGNER IS A FLORIDA LICENSED ARCHITECT OR | | ENGINEER, HE/SHE SHALL ALSO PROVIDE AN ORIGINAL SEAL | | AND WET SIGNATURE PER F.S. 61G15-16.003 AND FAC 23.002. | | | | 2. UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL WITH | | SIGNATURE OF DESIGNER AS APPLICABLE; USE THE REQUIRED | | NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | |
|
|