Plan Review Stops For Permit 20040244 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-11-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-02 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-02 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-06-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-12 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-12 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-13 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-13 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-10-28 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-10-28 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-10-28 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-10-27 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2020-10-27 |
Time |
|
Sent To |
|
|
Notes |
2020-10-27 14:02:28 | PASSED WITH PROVISO: | | THERE ARE WATER AND SEWER LINES IN THE VICINITY OF THIS | | PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE STATUTES, | | YOU MUST CALL 811 FOR UTILITY LOCATES AT LEAST TWO FULL | | BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION OR | | DEMOLITION WORK. INFORMATION CAN BE FOUND HERE: | | HTTP://WWW.SUNSHINE811.COM/ | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | CONCERNS, THANKS. | | | | RICK ROSSANO | | PROJECT COORDINATOR | | ENGINEERING SERVICES DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1098 | | FAX: (561) 494-1116 | | MOBILE: (561) 246-9525 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-06-25 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2020-06-25 |
Time |
|
Sent To |
I |
|
Notes |
2020-06-25 12:47:03 | 1. CITY STANDARDS VISIBILITY TRIANGLE: | | A. THE DASHED LINE ELEMENT IS WITHIN THE VISIBILITY | | TRIANGLE. IF THAT ELEMENT IS LESS THAN 18? NO PROBLEM, | | OTHERWISE A SLIGHT SETBACK IS NEEDED. SEE ATTACHED | | PICTURE. | | 2. STOP BAR LOCATION | | A. CLEARANCE OF VISIBILITY TRIANGLE PER DOT STANDARDS | | IS ACHIEVED THROUGH THE RELOCATION OF THE STOP LINE. | | THE ORIGINAL STOP LOCATION WOULD HAVE REQUIRED FURTHER | | SETBACK. | | B. HOWEVER, STOP BAR LOCATION HAS TO BE OUTSIDE OF | | EXISTING OR FUTURE PEDESTRIAN CROSSWALK (10? WIDE PER | | CITY CODE). SITE PLAN SHALL SHOW SUCH DISTANCE/WIDTH IS | | ACCOMMODATED. STOP BAR LOCATION SHALL BE REVISED IN | | CASE OF ENCROACHMENT. | | 3. SIDEWALK MUST BE CONSTRUCTED ALONG PROPOSED | | DEVELOPMENT FRONTAGE. SIDEWALK WIDTH: FROM PROPERTY | | LINE TO CONCRETE CURB, AND A MINIMUM OF 5?, IDEALLY | | 10?. IF NOT ENOUGH ROW, DEDICATION WOULD BE NECESSARY. | | | | VALERIO ORICCHIO, PE, PTOE | | CITY TRANSPORTATION ENGINEER | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2020-10-26 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-10-26 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-10-23 |
Time |
14:48 |
Sent To |
|
|
Notes |
2020-10-26 14:55:46 | 10/26/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER / INSPECTOR | | EMAIL: [email protected] OFFICE: 561 805-6720 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2020-11-04 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-11-04 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-11-04 |
Time |
11:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-11-03 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-11-03 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-10-22 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-06-25 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-06-09 |
Time |
07:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-05-05 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-05-05 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-05-01 |
Time |
08:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-13 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-09 |
Time |
08:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2020-10-26 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-10-26 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-10-26 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2020-10-26 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-10-26 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-10-23 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-11-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-11-02 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-11-02 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-06-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-06-12 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-06-12 |
Time |
15:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-04-13 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-04-13 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2020-11-04 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-11-04 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-11-04 |
Time |
|
Sent To |
|
|
Notes |
2020-11-04 12:31:47 | EASEMENT CONSENTS RECEIVED FROM: WPB, AT&T, FPL, | | COMCAST AND FPU FOR PERIMETER WALL LOCATED WITHIN THE 5 | | FT. WIDE UE LOCATED ON THE PROPERTY. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2020-11-02 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-11-02 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-11-02 |
Time |
|
Sent To |
|
|
Notes |
2020-11-02 14:11:27 | SPOKE TO MIKE WOOD ON 11/2/10. WAS ADVISED THAT THE | | PLANS WILL BE MODIFIED TO ELIMINATE THE PRIVACY WALL | | WITHIN THE 5 FT. WIDE UTILITY EASEMENT ALONG THE EAST | | SIDE OF THE PROPERTY UNTIL EASEMENT CONSENTS ARE | | OBTAINED; AT THAT POINT THE MIKE WOOD WILL COME BACK | | WITH A REVISION TO THE PERMIT TO PUT THE WALL BACK IN | | THE UE.. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2020-06-22 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-06-22 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-06-22 |
Time |
|
Sent To |
|
|
Notes |
2020-06-22 11:29:57 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE PLANS SHOWING THE PROPOSED NEW WALL HEIGHT IS | | NOW MISSING FROM THE REVISED PERMIT SET. THE HEIGHT OF | | THE WALL IS NEEDED TO DEMONSTRATE COMPLIANCE WITH THE | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS). PLEASE | | NOTE THAT THE WALL SHALL NOT EXCEED A MAXIMUM HEIGHT OF | | 4 FT. (AT GRADE) WITHIN THE REQUIRED FRONT SETBACK | | (AREA WITHIN THE FIRST 25 FT. FROM THE PROPERTY LINE | | ALONG N. FLAGLER DR.) AND MAXIMUM OF 6 FT. IN HEIGHT | | (AT GRADE) WITHIN THE REQUIRED SIDE AND REAR SETBACKS. | | NO PART OF THE WALL SHALL BE PLACED WITHIN THE SIGHT | | VISIBILITY TRIANGLE AND NO VEGETATION BETWEEN THE | | HEIGHT OF 18 INCHES AND 8 FT. SHALL BE PLACED WITHIN | | THE VISIBILITY TRIANGLE. PLEASE SHOW ALL ELEMENTS IN | | THE PLAN. | | | | [ALTHOUGH SOME OF THE REQUIRED ELEMENTS IN THE PLANS | | WERE SHOWN AT SOME POINT, THE INFORMATION HAS SINCE | | BEEN REMOVED. IT IS IMPORTANT THAT ALL RELEVANT | | INFORMATION IS PLACED IN THE PLANS.] | | | | | | | | NOTES: | | | | * ENGINEERING STOP ADDED TO REVIEW SIGHT VISIBILITY | | FROM TRAFFIC STANDPOINT. | | | | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: | | LANDSCAPING AND HARDSCAPES (I.E. DRIVEWAY AND | | WALKWAYS), GENERATOR, ACCESSORY SCREEN ENCLOSURES (I.E. | | FOR GENERATOR AND WASTE CONTAINERS), FIREPIT, ETC. | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * NEW PERIMETER PRIVACY WALL DETECTED. | | | | * REFERENCE MASTER PERMIT 19050386 (NEW SFR) | | | | * Z = SF7 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2020-05-05 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-05-05 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-05-05 |
Time |
|
Sent To |
|
|
Notes |
2020-05-05 15:23:38 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) PROPOSED PERIMETER PRIVACY WALL SHALL NOT EXCEED 18 | | INCHES WITHIN THE SIGHT VISIBILITY TRIANGLE IN | | ACCORDANCE WITH ZLDR S.94-305(E). THE HEIGHT OF THE | | WALL EXCEEDS THE HEIGHT LIMITATION. PLEASE ADDRESS. | | [4/13/2020 REPEAT COMMENT] | | | | | | NOTES: | | | | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: | | LANDSCAPING AND HARDSCAPES (I.E. DRIVEWAY AND | | WALKWAYS), GENERATOR, ACCESSORY SCREEN ENCLOSURES (I.E. | | FOR GENERATOR AND WASTE CONTAINERS), FIREPIT, ETC. | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * NEW PERIMETER PRIVACY WALL DETECTED. | | | | * REFERENCE MASTER PERMIT 19050386 (NEW SFR) | | | | * Z = SF7 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-04-13 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2020-04-13 |
Time |
|
Sent To |
|
|
Notes |
2020-04-13 07:50:41 | | | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) PROPOSED PERIMETER PRIVACY WALL SHALL NOT EXCEED 18 | | INCHES WITHIN THE SIGHT VISIBILITY TRIANGLE IN | | ACCORDANCE WITH ZLDR S.94-305(E). THE HEIGHT OF THE | | WALL EXCEEDS THE HEIGHT LIMITATION. PLEASE ADDRESS. | | | | | | NOTES: | | | | * SEPARATE PERMITS AND REVIEWS REQUIRED FOR: | | LANDSCAPING AND HARDSCAPES (I.E. DRIVEWAY AND | | WALKWAYS), GENERATOR, ACCESSORY SCREEN ENCLOSURES (I.E. | | FOR GENERATOR AND WASTE CONTAINERS), FIREPIT, ETC. | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * NEW PERIMETER PRIVACY WALL DETECTED. | | | | * REFERENCE MASTER PERMIT 19050386 (NEW SFR) | | | | * Z = SF7 | | |
|
|