Plan Review Details - Permit 20040151
Plan Review Stops For Permit 20040151 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-04-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-04-16 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-04-16 |
Time |
12:36 |
Sent To |
|
|
Notes |
2020-04-16 12:38:47 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | REVISION IS DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT CALCULATIONS, DETAILS AND ANY OTHER DOCMENTS | | NECESSARY TO SHOW THAT REDUCING THE OVERFLOW SCUPPERS | | FROM 4" TO 3" WILL NOT REDUCE THE REQUIRED AMOUNT OF | | RAIN WATER DISCHARGE FORM THE ROOF MORE THAN REQUIRED | | BY CODE. FBC 107.2.1.2 | | | | 2) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | CITY RE-SUBMITTAL FORM. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-04-20 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-04-13 |
Time |
16:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-04-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-04-20 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-04-20 |
Time |
07:42 |
Sent To |
|
|
Notes |
2020-04-20 09:27:15 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT #20040151 | | 4/20/2020 | | | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) REVISE SHEETS A.2.4.6 AND P.5.4.3 ROOF PLANS TO SHOW | | THE LOCATIONS AND CHANGES IN SIZE OF THE EMERGENCY | | OVERFLOW DRAINS AND DRAIN PIPE RUNS. PLEASE INCLUDE | | CALCULATIONS AND DRAIN AND DRAIN PIPE SIZES AND | | DETAILS- SEE SECTION 1108.3 FBC P. | | | | 2) A.8.4.1: THE REVISED TRUSS/EAVE DETAIL 18 APPEARS TO | | SHOW AN EMERGENCY DRAIN PIPE DISCHARGING BEHIND THE TIE | | BEAM INTO WHAT APPEARS TO BE A CAVITY INSIDE THE | | BUILDING. REFER TO SECTION 1108.2 AND CLARIFY. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-04-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-04-16 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-04-16 |
Time |
12:37 |
Sent To |
|
|
Notes |
2020-04-16 12:42:29 | THE CURRENT DRAWING IS DIGITALLY SIGNED. THE SIGNATURES | | WILL HAVE TO BE VERIFIED ON ANY NEW SUBMITTALS. |
|
|
|