Plan Review Details - Permit 20040008
Plan Review Stops For Permit 20040008
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-06-11 Cont ID  
Sent By rmcphers Date 2020-06-11 Time 13:25 Rev Time 0.00
Received By rmcphers Date 2020-06-11 Time 13:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-04-09 Cont ID  
Sent By rmcphers Date 2020-04-09 Time 10:41 Rev Time 0.00
Received By rmcphers Date 2020-04-09 Time 10:41 Sent To  
Notes
2020-04-09 10:47:30ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE
 PRODUCT APPROVAL.
 2) PLEASE PROVIDE SIGNED AND SEALED ADDITIONAL
 ATTACHMENT DETAILS FOR ROOF ZONES 2 AND 3 THAT MAY NOT
 MEET THE MAXIMUM DESIGN PRESSURE FOR THE SYSTEM USED
 PER PRODUCT APPROVAL "GENERAL LIMITATION NUMBER" 7.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-04-07 Cont ID  
Sent By rmcphers Date 2020-04-07 Time 13:27 Rev Time 0.00
Received By rmcphers Date 2020-04-07 Time 11:50 Sent To  
Notes
2020-04-07 13:27:45ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE CLARIFY WHAT THE TYPE OF ROOFINGING. - THE
 ROOFING FORM 100 SHOWS SHINGLES AND A DIFFERENT ADDRESS
 - THE APPLICATION SHOWS TORCH DOWN.
 2) CANNOT RECOVER OVER THE EXISTING ROOF PER FBC R908.3
 (5).
 3) NEED COMPLETE PRODUCT APPROVALS - FRONT PAGES AND
 THE INSTALLATION INSTRUCTIONS. (FRONT PAGES ARE MISSING
 FROM THE PRODUCT APPROVAL PROVIDED).
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-06-11 Cont ID  
Sent By rmcphers Date 2020-06-11 Time 13:26 Rev Time 0.00
Received By rmcphers Date 2020-06-09 Time 07:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-04-09 Cont ID  
Sent By rmcphers Date 2020-04-09 Time 10:47 Rev Time 0.00
Received By rmcphers Date 2020-04-08 Time 11:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-07 Cont ID  
Sent By rmcphers Date 2020-04-07 Time 13:28 Rev Time 0.00
Received By rmcphers Date 2020-04-06 Time 07:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-04-07 Cont ID  
Sent By rmcphers Date 2020-04-07 Time 13:28 Rev Time 0.00
Received By rmcphers Date 2020-04-07 Time 13:28 Sent To  
Notes
2020-04-07 13:28:40NOT REQUIRED AT THIS TIME