Plan Review Stops For Permit 20031386 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-08-13 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-08-12 |
Time |
17:29 |
Sent To |
|
|
Notes |
2020-08-13 08:36:44 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | 3RD BUILDING REVIEW APPROVED WITH PROVISO: | | | | PRIOR TO INSPECTIONS, PLEASE PROVIDE THE PRODUCT | | APPROVALS FOR LARGE MISSILE IMPACT RESISTANT WINDOWS | | AND CARRIAGE DOORS INCLUDING STATIONARY PANELS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-07-30 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2020-07-30 |
Time |
14:34 |
Sent To |
|
|
Notes |
2020-07-30 14:34:25 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | ALTERNATE: CONTACT SAMANTHA HILL (561) 805-6724 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1. FBC B 107.2.1. SUBMITTED FLORIDA STATE PRODUCT | | APPROVAL FL11870-R5 IS FOR WINDOW MULLIONS. PLEASE | | PROVIDE TWO SETS OF PRODUCT APPROVALS/NOA?S FOR THE | | PROPOSED WINDOWS TO BE USED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-31 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-03-31 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-30 |
Time |
16:50 |
Sent To |
|
|
Notes |
2020-03-31 10:36:26 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | 1) FBC B 107.2.1, PROVIDE THE EMBEDMENT DEPTH OF THE | | INTERIOR AND EXTERIOR COLUMN ANCHOR BOLTS. | | 2) FBC B 107.2.1, PROVIDE THE SIZE AND QUANTITY OF | | FASTENERS FOR THE COLUMN SPLIT PLATE CONNECTIONS TO THE | | BEAMS ABOVE AT BOTH INTERIOR AND EXTERIOR COLUMNS. | | 3) FBC B 107.2.1, PROVIDE CONCRETE/BLOCK WALL | | REINFORCEMENT DETAIL FOR AREA BELOW NEW BEAM SUPPORTING | | POCKETS AT KITCHEN AND BEDROOM #3 EXTERIOR WALLS. | | 4) FBC B 107, PROVIDE ROOFING DETAILS FOR UNDER | | ELEVATED BALCONY DECKING. | | 5) FBC B 107, PROVIDE ALL PRODUCT APPROVALS FOR | | WINDOWS, DOORS, AND ROOFING MATERIALS. | | 6) FBC B 310, THE OCCUPANCY CLASSIFICATION INDICATED ON | | THE PLANS IS R-3 BUT IT APPEARS THAT THIS OCCUPANCY | | CLASSIFICATION IS R-2 PER THE FLORIDA BUILDING CODE. | | PLEASE ADJUST ON PLANS AND CLARIFY. | | | | NOTE: A ROOFING SUB-PERMIT IS REQUIRED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-08-11 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-08-11 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-08-11 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-04-01 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-04-01 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-04-01 |
Time |
10:19 |
Sent To |
|
|
Notes |
2020-04-01 10:56:03 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | 2.LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE SUITABLE | | FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC 410.10(D); | | FBC RE E4003.11 | | 3.PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | 4.PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF SERVICE | | EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, WIRE AND | | BREAKER SIZES FOR SERVICE AND FEED TO ANY SUB-PANEL(S). | | SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING | | TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94, | | 408.30; FBC RE E3706.1, E3608.1, E3609.3; WPB FBC | | 107.2.1 | | 5.PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER | | CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | 107.2.1 | | 6.SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | FROM A RECEPTACLE OUTLET. PROVIDE CORRECTION. NEC | | 210.52; FBC RE E3901.2.1 | | 7.IDENTIFY OLD AND NEW WORK | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | PHIL PETTY | | ELECTRICAL PLANS EXAMINER | | 561-805-6742 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2020-04-09 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-04-09 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-04-09 |
Time |
10:54 |
Sent To |
|
|
Notes |
2020-04-09 10:55:09 | UTILIZING RAILING OPTION "C" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-08-13 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-08-12 |
Time |
09:42 |
Sent To |
|
|
Notes |
2020-08-12 09:42:48 | ROUTED TO MECHANICAL BIN |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-08-11 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2020-08-06 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-07-24 |
Time |
07:19 |
Sent To |
|
|
Notes |
2020-08-05 08:08:52 | ROUTED TO ELECTRICAL IN BOX | 2020-07-24 07:56:38 | ROUTED TO BLDG. MISC 1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-04-11 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-04-11 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2020-03-30 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2020-09-21 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-09-21 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-09-21 |
Time |
16:54 |
Sent To |
|
|
Notes |
2020-09-21 16:57:40 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | IMPACT FEE REVIEW APPROVED: | | | | THE OWNER RETURNED THE PLAN STAMPED BY THE COUNTY AND | | PROVIDED A RECEIPT (MU-2020-032354-0000). |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-04-01 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-04-01 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-04-01 |
Time |
09:33 |
Sent To |
|
|
Notes |
2020-04-01 09:30:54 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | IMPACT FEES - PAPER SUBMITTALS | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-08-13 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-08-05 |
Time |
14:25 |
Sent To |
|
|
Notes |
2020-08-13 09:10:39 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | MECHANICAL REVIEW APPROVED WITH PROVISO: | | | | PRIOR TO MECHANICAL WORK, PROVIDE A MECHANICAL | | SUB-PERMIT INCLUDING PLANS, THE AHRI SHEETS FOR HVAC | | EQUIPMENT, AND MANUFACTURER'S SPECIFICATIONS FOR THE | | RANGE HOOD INCLUDING EXHAUST HOOD CAPACITY IN CFM'S |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-03-31 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-03-31 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-31 |
Time |
10:37 |
Sent To |
|
|
Notes |
2020-03-31 10:50:54 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | MECHANICAL REVIEW DENIED: | | | | 1) FBC B 107, PROVIDE ALL HVAC DETAILS, AS PER HVAC | | NOTE ON PAGE A-7 OF SUBMITTED PLANS, INCLUDING | | EQUIPMENT (A/C HANDLER & CONDENSING UNIT), DUCT LAYOUT | | W/SIZES AND CFM COUNT, EXTERIOR UNIT ANCHORING DETAIL, | | AHRI SHEETS AND A/C CALCULATIONS. | | | | NOTE: A MECHANICAL SUB-PERMIT IS REQUIRED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-04-07 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2020-04-07 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2020-04-03 |
Time |
15:50 |
Sent To |
|
|
Notes |
2020-04-07 16:33:59 | 04/07/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. PLEASE PROVIDE A BETTER DETAIL PLUMBING RISER | | DIAGRAM PER THE WPB AMENDMENTS TO THE FBC SEC. | | 107.3.5.3 (11) RESIDENTIAL PLUMBING. THE SINK AND LAVS | | ARE NOT SHOWN PROPERLY VENTED, THE WASHING MACHINE NEED | | TO BE ON A 3" DRAINAGE LINE PER MANUFACTURES | | SPECIFICATION, SEPARATE BATHROOM GROUP AND A WET VENT | | SYSTEM MAY BE A COMPLEXES DIRECTION. | | | | 2. WASHING MACHINE VALVES NEED TO BE ACCESSIBLE WITHOUT | | MOVING THE UNIT, THEY MAY BE ON THE SIDE, A NOTE WILL | | BE SUFFICIVE ON PLANS REFERRING TO 2017 PER THE | | 2903.9.3. | | | | 3. PLEASE SHOW THE SOURCE OF HOT WATER AND LOCATION PER | | THE 2017 FBC SEC R 2722.2. | | | | 4. PLEASE IDENTIFY YOUR VENT LINE THROUGH THE ROOF AS | | DASH LINE PER THE WPB AMENDMENTS TO THE FBC SEC. | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-04-09 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-04-09 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-04-09 |
Time |
10:55 |
Sent To |
|
|
Notes |
|
|