Plan Review Details - Permit 20031336
Plan Review Stops For Permit 20031336
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-10-16 Cont ID  
Sent By cthroop Date 2020-10-16 Time 15:36 Rev Time 0.00
Received By cthroop Date 2020-10-16 Time 14:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-28 Cont ID  
Sent By cthroop Date 2020-09-28 Time 08:48 Rev Time 0.00
Received By cthroop Date 2020-09-28 Time 07:43 Sent To  
Notes
2020-09-28 08:53:07PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. BASED ON THE HEIGHT OF THE OPENING OF THE PROPOSED
 SGD, DESIGN PRESSURE CALCULATIONS ARE REQUIRED TO BE
 SIGNED AND SEALED BY A DESIGN PROFESSIONAL.
 SEE COMMENTS UNDER SIGNATURE REVIEW.
  
 2. PAGE 10 OF 11 ON PRODUCT APPROVAL FL 20838-R2 STATES
 BUILDING SUBSTRATE IS WOOD. THIS STRUCTURE IS A
 CONCRETE STRUCTURE. PLEASE CORRECT INFORMATION PROVIDED
 AND RE-SUBMIT.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, SGD DOOR SUBMITTALS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-10-16 Cont ID  
Sent By cthroop Date 2020-10-16 Time 15:38 Rev Time 0.00
Received By cthroop Date 2020-10-14 Time 10:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-28 Cont ID  
Sent By cthroop Date 2020-09-28 Time 08:53 Rev Time 0.00
Received By cthroop Date 2020-09-15 Time 14:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-03 Cont ID  
Sent By lmarchan Date 2020-04-03 Time 09:40 Rev Time 0.00
Received By lmarchan Date 2020-03-30 Time 13:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-10-30 Cont ID  
Sent By pvalenti Date 2020-10-30 Time 13:58 Rev Time 0.00
Received By pvalenti Date 2020-10-30 Time 13:58 Sent To  
Notes
2020-10-30 14:00:27PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
  
 SIGNATURE REVIEW APPROVED BY SUBMITTED ORIGINAL SIGNED
 & SEALED WINDLOAD DOCUMENT.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-10-16 Cont ID  
Sent By cthroop Date 2020-10-16 Time 15:36 Rev Time 0.00
Received By cthroop Date 2020-10-16 Time 14:59 Sent To  
Notes
2020-10-16 15:38:25PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE
 BELOW.
  
 RE: ASCE 7-10 DESIGN PRESSURE CALCULATIONS.
  
 DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET / DIGITAL SIGNATURE IS
 NOT CONSIDERED A DIGITAL SIGNATURE.
  
 EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF
 (OR MAIL) ONE PAPER ORIGINAL WITH A WET SEAL AND
 SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-09-28 Cont ID  
Sent By cthroop Date 2020-09-28 Time 08:47 Rev Time 0.00
Received By cthroop Date 2020-09-28 Time 07:43 Sent To  
Notes
2020-09-28 08:48:37PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: ASCE 7-10 DESIGN PRESSURE CALCULATIONS.
  
 DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET / DIGITAL SIGNATURE IS
 NOT CONSIDERED A DIGITAL SIGNATURE.
  
 EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF
 (OR MAIL) ONE PAPER ORIGINAL WITH A WET SEAL AND
 SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved