Plan Review Stops For Permit 20031298 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-10-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-07 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-07 |
Time |
07:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-30 |
Time |
06:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-30 |
Time |
06:05 |
Sent To |
|
|
Notes |
2020-07-30 07:39:35 | PROVISO: ICYNENE SPRAY FOAM INSULATION ICC-ES REPORT TO | | BE ON-SITE FOR INSPECTION. CT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-05-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-07 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-07 |
Time |
07:42 |
Sent To |
|
|
Notes |
2020-05-07 16:00:37 | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | PLAN REVIEW - BUILDING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE SURVEY. | | PROVIDE SITE PLAN. ? DRAINAGE/SURVEY | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | INCLUDED ON A BOUNDARY LINE SURVEY. | | | | 2. PROVIDE SOILS REPORT. | | FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE | | CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | DESIGN PROFESSIONAL. | | | | 3. PROVIDE PRODUCT APPROVALS FOR PROPOSED WINDOWS AND | | EXTERIOR DOORS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | 4. PROVIDE ICC ES EVALUATION REPORT FOR ICYNENE ATTIC | | INSULATION. INDICATE WHAT SYSTEM WILL BE INSTALLED. A | | COPY OF THE INSTALLATION INSTRUCTIONS SHALL BE ON-SITE | | FOR THE CITY INSPECTOR. | | | | 5. RESIDENTIAL ELEVATORS SHALL COMPLY WITH FBC SECTION | | 3013. | | PROVIDE A STRUCTURAL DETAIL FOR ELEVATOR SHAFT. | | PROVIDE STRUCTURAL CONNECTION DETAIL FOR ELEVATOR TO | | STRUCTURE. | | PROVIDE MANUFACTURERS SPECIFICATIONS. | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-30 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-30 |
Time |
06:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-05-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-08 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-07 |
Time |
07:42 |
Sent To |
|
|
Notes |
2020-05-08 11:57:41 | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | PLAN REVIEW - ELECTRICAL | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE AIC RATING OF TRANSFORMER FROM POWER | | COMPANY. | | | | PROVIDE ACTUAL TRANSFORMER SECONDARY FAULT CURRENT FROM | | UTILITY. | | | | E3404.2 INTERRUPTING RATING. | | | | EQUIPMENT INTENDED TO INTERRUPT CURRENT AT FAULT LEVELS | | SHALL HAVE A MINIMUM INTERRUPTING RATING OF 10,000 | | AMPERES. EQUIPMENT INTENDED TO INTERRUPT CURRENT AT | | LEVELS OTHER THAN FAULT LEVELS SHALL HAVE AN | | INTERRUPTING RATING AT NOMINAL CIRCUIT VOLTAGE OF NOT | | LESS THAN THE CURRENT THAT MUST BE INTERRUPTED. (110.9) | | | | AIC RATING OF SERVICE DISCONNECT AND PANEL | | FBC R E3606.3AVAILABLE SHORT-CIRCUIT CURRENT. | | SERVICE EQUIPMENT SHALL BE SUITABLE FOR THE MAXIMUM | | FAULT CURRENT AVAILABLE AT ITS SUPPLY TERMINALS, BUT | | NOT LESS THAN 10,000 AMPERES. (110.9) | | | | | | 2. PROVIDE INTERSYSTEM BONDING CONNECTION AT SERVICE. | | | | PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | | 3. PANEL SIZE CALCULATION FOR PANEL B USES INCORRECT | | KVA. TOTAL PANEL KVA IS 2.2 KVA. PANEL SIZE CALCULATION | | USES 18.7 KVA. | | | | PLEASE CORRECT. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 4. HIGH EFFICACY LAMPS. | | | | PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS". | | A NOTE ON THE PLAN WILL SUFFICE. FBC EC R404.1 | | | | 5. OUTLET IN POWDER ROOM APPEARS TO EXCEED THE 36 INCH | | MINIMUM REQUIREMENT PER E3901.6. | | | | PLEASE VERIFY | | | | 6. OUTLETS FOR GARAGE DOOR OPENERS MISSING FROM PLAN. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2020-05-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-08 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-07 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-30 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-30 |
Time |
06:05 |
Sent To |
|
|
Notes |
2020-07-30 07:36:32 | SEPERATE GAS PERMIT REQUIRED. NO GAS REVIEW PERFORMED. | | CT |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2020-05-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-07 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-07 |
Time |
14:59 |
Sent To |
|
|
Notes |
2020-05-07 15:45:03 | SEPERATE GAS PERMIT REQUIRED. NO GAS REVIEW PERFORMED. | | CT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-10-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-10-20 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-09-23 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-07-31 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-07-31 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-07-13 |
Time |
09:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-06-11 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-06-11 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-04-24 |
Time |
08:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2021-04-12 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2021-04-12 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-10-06 |
Time |
09:41 |
Sent To |
|
|
Notes |
2021-04-12 13:09:56 | MU-2021-8433 & MU-2020-39388 - $9781.20 - PAID | 2020-10-06 09:41:57 | EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-05-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-07 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-07 |
Time |
07:41 |
Sent To |
|
|
Notes |
2020-05-07 13:31:50 | IMPACT FEES - DIGITAL SUBMITTALS | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-07-23 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-07-23 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-07-23 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2020-04-27 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-04-27 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-04-27 |
Time |
15:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-30 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-30 |
Time |
06:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-05-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-08 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-07 |
Time |
07:42 |
Sent To |
|
|
Notes |
2020-05-08 09:13:39 | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | | | PLAN REVIEW - PLUMBING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | REFERENCE PLUMBING ISO DIAGRAHM ON PLAN PAGE P2.10 FOR | | THE FOLLOWING: | | | | 1. 1ST FLOOR KITCHEN GROUP MISSING DISH WASHER. | | | | 2. 2ND FLOOR INDICATES AN EXTRA LAV NEXT TO LAUNDRY | | FLOOR DRAIN THAT IS NOT SHOWN ON PLUMBING PLAN. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-30 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-30 |
Time |
06:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-05-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-07 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-07 |
Time |
07:42 |
Sent To |
|
|
Notes |
2020-05-07 12:47:04 | PLAN REVIEW - ROOFING | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | 1. ROOFING PERMIT REQIUIRED. | | PERMITS | | 105.1 REQUIRED. | | | | 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | SYSTEM COMPONENTS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-10-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-10-07 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-10-07 |
Time |
07:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-07-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-07-30 |
Time |
06:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-07-30 |
Time |
06:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-05-07 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-07 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-07 |
Time |
07:41 |
Sent To |
|
|
Notes |
2020-05-07 12:44:17 | PLAN REVIEW - DIGITAL SIGNATURES AND SEALS | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER ? BUILDING - PX3169 | | PLANS EXAMINER ? 1&2 FAMILY - SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | DESIGN PROFESSIONALS | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | 3. FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY | | DIGITAL SIGATURES AND SEALS PER FS 668.003. | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-09-25 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2020-09-25 |
Time |
|
Sent To |
|
|
Notes |
2020-09-25 12:45:27 | ******ZONING PROVISO******* | | | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | THE FOLLOWING CONDITIONS SHALL BE ADDRESSED: | | | | 1. A LANDSCAPE PERMIT, WHIICH INCLUDES A LANDSCAPE | | PLAN, SHALL BE SUBMITTED TO THE BUILDING DIVISION FOR | | REVIEW. | | | | 2. THE LANDSCAPE MATERIAL SHOWN ON THE APPOVED | | LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL | | LANDSCAPE INSPECTION. | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2020-07-31 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-07-31 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2020-07-31 |
Time |
|
Sent To |
|
|
Notes |
2020-07-31 15:19:58 | *************ZONING REVIEW FAILED**************(REPEAT | | COMMENTS FROM LAST REVIEW) | | | | PROVIDE A SURVEY AND A SITE PLAN FOR THE PROPOSED HOME. | | | | CODE LIMITS THE BUIDLING HEIGHT TO 30 FEET. | | | | DIMENSION THE OVERHANG. IT CANNOT EXTEND MORE THAN 3 | | FEET. | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | PERMIT. SHOWING THE FOLLOWING: | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | BEACH | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | OR PORTION THEREOF | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | OR PORTION THEREOF | | | | THE PROPOSED DRIVEWAY, POOL, AND FENCE REQUIRE A | | SEPARATE PERMIT. | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-06-11 |
|
|
Cont ID |
|
Sent By |
awotten |
Date |
2020-06-11 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2020-06-11 |
Time |
|
Sent To |
|
|
Notes |
2020-06-11 14:38:16 | *************ZONING REVIEW FAILED************** | | | | PROVIDE A SURVEY AND A SITE PLAN FOR THE PROPOSED HOME. | | | | CODE LIMITS THE BUIDLING HEIGHT TO 30 FEET. | | | | DIMENSION THE OVERHANG. IT CANNOT EXTEND MORE THAN 3 | | FEET. | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | PERMIT. SHOWING THE FOLLOWING: | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | BEACH | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | OR PORTION THEREOF | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | OR PORTION THEREOF | | | | THE PROPOSED DRIVEWAY, POOL, AND FENCE REQUIRE A | | SEPARATE PERMIT. | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] | | |
|
|