Plan Review Details - Permit 20031189
Plan Review Stops For Permit 20031189
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-04-17 Cont ID  
Sent By rmcdouga Date 2020-04-17 Time 12:46 Rev Time 0.00
Received By rmcdouga Date 2020-04-17 Time 12:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-03-31 Cont ID  
Sent By rmcdouga Date 2020-03-31 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2020-03-31 Time 08:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-04-27 Cont ID  
Sent By jpearson Date 2020-04-27 Time 14:59 Rev Time 0.00
Received By jpearson Date 2020-04-27 Time 14:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-04-16 Cont ID  
Sent By jpearson Date 2020-04-16 Time 09:21 Rev Time 0.00
Received By jpearson Date 2020-04-16 Time 08:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-03-31 Cont ID  
Sent By rmcdouga Date 2020-03-31 Time 08:35 Rev Time 0.00
Received By rmcdouga Date 2020-03-31 Time 08:31 Sent To  
Notes
2020-03-31 08:36:11CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1) SHOW COMPLIANCE WITH FBCR - E 4204.2 FOR
 EQUIPOTENTIAL BONDING.
  
 2) THE FEEDERS FROM THE BUILDING ELECTRICAL PANEL TO
 THE 125 AMP POOL PANEL ARE UNDERSIZED. NEC 310.15
  
 NOTE: SEPARATE PERMIT IS REQUIRED FOR THE ELECTRICAL
 SERVICE CHANGE.
  
 END OF COMMENTS.
  
 SINCERELY,
  
 ROBERT MCDOUGAL
 COMBINATION PLANS EXAMINER
 561-805-6714
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-04-27 Time   Rev Time 0.00
Received By lmarchan Date 2020-04-16 Time 10:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-04-16 Time   Rev Time 0.00
Received By lmarchan Date 2020-04-08 Time 15:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-01 Cont ID  
Sent By shill Date 2020-04-01 Time 17:41 Rev Time 0.00
Received By shill Date 2020-03-25 Time 11:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-03-31 Cont ID  
Sent By thunt Date 2020-03-31 Time 10:13 Rev Time 0.00
Received By tklarge Date 2020-03-31 Time 10:05 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2020-04-27 Cont ID  
Sent By jpearson Date 2020-04-27 Time 15:01 Rev Time 0.00
Received By jpearson Date 2020-04-27 Time 15:01 Sent To  
Notes
2020-04-27 15:01:22ONLY ONE OF THE THREE SHEETS IN SET HAS A DIGITAL
 SIGNATURE. THE SHEET THAT IS DIGITALLY SIGNED IS
 SELF-CERTIFIED BY THE ENGINEER, WHICH IS NOT PERMITTED
 PER FBPE. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET
 OF PLAN IS REQUIRED TO BE SIGNED AND SEALED BY THE
 PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN
 REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD
 PARTY VERIFICATION. PROVIDE CORRECTION. ALTERNATIVELY,
 A SIGNED/SEALED PAPER SET MAY BE SUPPLIED TO THE
 BUILDING DEPARTMENT WHEN ALL TRADES ARE APPROVED. WPB
 FBC 107.1; FS 471/481

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-04-16 Cont ID  
Sent By jpearson Date 2020-04-16 Time 08:43 Rev Time 0.00
Received By jpearson Date 2020-04-16 Time 08:43 Sent To  
Notes
2020-04-16 08:43:35SPOKE WITH NORM CABRERA, PE. HE HAS A DIGITAL SIGNATURE
 AND WILL PROVIDE APPLICANT WITH DIGITALLY SIGNED
 DOCUMENTS TO RESUBMIT. ([email protected])
  
  
 THE PLANS ARE NOT DIGITALLY SIGNED AND SEALED PER FL.
 ADMIN. CODE RULE 61G15-23.004, 61G15-23.005.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-03-31 Cont ID  
Sent By tklarge Date 2020-03-31 Time 10:19 Rev Time 0.00
Received By tklarge Date 2020-03-31 Time 10:16 Sent To  
Notes
2020-03-31 10:43:38SPOKE WITH NORM CABRERA, PE. HE HAS A DIGITAL SIGNATURE
 AND WILL PROVIDE APPLICANT WITH DIGITALLY SIGNED
 DOCUMENTS TO RESUBMIT. ([email protected])
  
  
2020-03-31 10:19:45THE PLANS ARE NOT DIGITALLY SIGNED AND SEALED PER FL.
 ADMIN. CODE RULE 61G15-23.004, 61G15-23.005.

Review Stop Z ZONING
Rev No 1 Status P Date 2020-04-01 Cont ID  
Sent By rfalcone Date 2020-04-01 Time 12:04 Rev Time 0.00
Received By rfalcone Date 2020-04-01 Time 12:04 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved