Plan Review Details - Permit 20030934
Plan Review Stops For Permit 20030934
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-03-23 Cont ID  
Sent By pvalenti Date 2020-03-23 Time 13:44 Rev Time 0.00
Received By pvalenti Date 2020-03-23 Time 13:44 Sent To  
Notes
2020-03-23 13:45:51ASBESTOS REQUIREMENTS:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-23 Cont ID  
Sent By pvalenti Date 2020-03-23 Time 13:38 Rev Time 0.00
Received By pvalenti Date 2020-03-23 Time 13:38 Sent To  
Notes
2020-03-23 13:43:15PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107, PLEASE PROVIDE DETAILS FOR THE REPLACEMENT
 WALL, AS THIS WALL APPEARS TO BE IN A LOCATION
 REQUIRING FIRE RATING AND MOISTURE RESISTANCE.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-03-23 Cont ID  
Sent By pvalenti Date 2020-03-23 Time 13:45 Rev Time 0.00
Received By pvalenti Date 2020-03-18 Time 08:44 Sent To  
Notes
2020-03-20 08:06:433/20 ROUTED TO BLDG MISC 2
2020-03-19 08:44:35ROUTED TO PLUMBING INBOX

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-03-19 Cont ID  
Sent By lcrespo Date 2020-03-19 Time 19:14 Rev Time 0.00
Received By lcrespo Date 2020-03-19 Time 19:14 Sent To  
Notes
2020-03-19 19:22:3903/19/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1.
  
 2. PLEASE PROVIDE A DETAIL OF HOW SHOWER PAN IS GOING
 TO BE INSTALLED, IT MUST HAVE A SLOPED MORTAR BED THAT
 IS PRE-PITCHED BENEATH PRIOR TO LINER INSTALLATION OF
 1/4" IN PER FOOT TOWARD THE DRAIN, MUST HAVE DAM
 CORNER, BACKING AROUND THE PERIMETER AND BEFORE FINAL
 MORTAR APPLICATION PLACE SOME PEA GRAVEL OVER WEEP
 HOLES SO THE MORTAR DOES NOT COVER THEM PER
 MANUFACTURES SPECIFICATIONS AND PER THE 2017 FBC
 SECTION R 2709.2 LINING REQUIRED.
  
 3. INDIVIDUAL SHOWER AND TUB/ SHOWER COMBINATION VALVES
 SHALL BE EQUIPPED WITH CONTROL VALVES OF THE
 PRESSURE-BALANCE, THERMOSTATIC-MIXING OR COMBINATION
 PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE TYPES WITH A
 HIGH LIMIT STOP IN ACCORDANCE WITH ASSE 1016/ASME
 A112.1016/CSA B125.16. THE HIGH LIMIT STOP SHALL BE SET
 TO LIMIT THE WATER TEMPERATURE TO NOT GREATER THAN 120
 F (49 C). IN-LINE THERMOSTATIC VALVES SHALL NOT BE USED
 FOR COMPLIANCE WITH THIS SECTION PER THE 2017 FBC
 SECTION R 2708.4, SHOWER CONTROL VALVES.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM