Plan Review Stops For Permit 20030904 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-09-18 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-09-18 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-09-18 |
Time |
08:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-09-11 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-09-11 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-09-11 |
Time |
15:45 |
Sent To |
|
|
Notes |
2020-09-11 15:54:38 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | 2ND BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, THE INFORMATION PROVIDED ON THE | | SUBMITTED SKETCHES AND SCHEDULES ARE NOT CLEAR AS TO | | THE CHANGES FROM HORIZONTAL ROLLER TO CASEMENT TYPE | | WINDOWS. PLEASE RESUBMIT THE DOCUMENTS, CLEARLY | | INDICATING THE CHANGES ON WINDOW OPENINGS THAT REQUIRE | | CASEMENT WINDOWS SUCH AS WINDOW OPENINGS # 9, 10 & 11. | | | | NOTE: MAKE SURE THAT THE CHANGES INDICATED ON SUBMITTED | | PLANS ARE ACCURATE AND THAT THE REQUIREMENTS OF THE | | HISTORIC REVIEW HAVE BEEN MET. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-03-19 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-19 |
Time |
15:26 |
Sent To |
|
|
Notes |
2020-03-19 15:33:19 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | FBC R 310.2.1, THE MASTER BEDROOM WINDOWS (HORIZONTAL | | ROLLERS) # 9, 10, AND 11 DO NOT MEET THE CLEAR OPENING | | SIZE REQUIREMENTS. | | | | NOTE: ONLY ONE OF THE MASTER BEDROOM WINDOWS NEEDS TO | | MEET THE CLEAR OPENING REQUIREMENT OF 24" HIGH AND 20" | | WIDE. | | PLEASE RESUBMIT WITH A WINDOW THAT WILL MEET THE | | REQUIRED CLEAR OPENING SIZE. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-09-22 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-09-22 |
Time |
10:30 |
Sent To |
|
|
Notes |
2020-09-22 10:29:59 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | CONDITION(S): | | 1. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL FRAME | | OPENING AND MATCH THE INSET/LOCATION/PLACEMENT/DEPTH OF | | THE ORIGINAL WINDOWS WITHIN THE WINDOW FRAME OPENING. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2020-09-11 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-09-11 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-09-04 |
Time |
13:00 |
Sent To |
|
|
Notes |
2020-09-11 14:57:19 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | 1. THE OG(EE) MUNTIN PROFILE FOR THE ES WINDOW IS NOT | | AN APPROPRIATE MUNTIN FOR THIS PROPERTY. REVISE PER | | HISTORIC PRESERVATION BOARD CONDITION TO A PYRAMID | | PROFILE. IF ES WINDOWS DOES NOT OFFER A PYRAMID | | PROFILE, ANOTHER WINDOW MANUFACTURER MAY BE REQUIRED. | | 2. REVISE WINDOW SCHEDULE/FLOOR PLAN TO COMPLY WITH | | HISTORIC PRESERVATION BOARD APPROVAL. | | | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | PLANNING DIVISION | | [email protected] | OFFICE: 561.822.1428 | TTY: | | 800.955.8771 | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | FL 33402 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2020-03-23 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2020-03-23 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2020-03-23 |
Time |
11:23 |
Sent To |
PC |
|
Notes |
2020-03-23 11:23:47 | HISTORIC REVIEW FAILED. | | CERTIRFICATE OF APPROPRIATNESS APPLICATION REQUIRED TO | | BE SUBMITTED AND CASE HEARD BY THE HISTORIC | | PRESERVATION BOARD. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-09-17 |
Time |
17:24 |
Sent To |
|
|
Notes |
2020-09-17 17:24:36 | TO PV DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-09-11 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-09-11 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-09-02 |
Time |
15:55 |
Sent To |
|
|
Notes |
2020-09-02 17:01:41 | ROUTED TO ZONING |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-03-23 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2020-03-23 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2020-03-18 |
Time |
12:25 |
Sent To |
|
|
Notes |
|
|