Plan Review Details - Permit 20030880
Plan Review Stops For Permit 20030880
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-04-07 Cont ID  
Sent By ccole Date 2020-04-07 Time 12:40 Rev Time 0.00
Received By ccole Date 2020-04-07 Time 12:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-25 Cont ID  
Sent By rmcphers Date 2020-03-25 Time 10:02 Rev Time 0.00
Received By rmcphers Date 2020-03-25 Time 08:49 Sent To  
Notes
2020-03-25 09:55:48WINDOWS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE 2ND FLOOR ADDED WINDOW SILL HEIGHT
 TO COMPLY WITH FBC R312.2.1 (GUARDS MAY BE REQUIRED)
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-04-06 Cont ID  
Sent By ppetty Date 2020-04-06 Time 11:39 Rev Time 0.00
Received By ppetty Date 2020-04-06 Time 11:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-03-30 Cont ID  
Sent By ppetty Date 2020-03-30 Time 09:55 Rev Time 0.00
Received By ppetty Date 2020-03-30 Time 09:44 Sent To  
Notes
2020-03-30 09:55:09CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1.NEW AND EXISTING NOTES IN CONFLICT
 2.FOR A ONE FAMILY DWELLING AND EACH UNIT OF A
 TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST
 ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND
 NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE
 INSTALLED AT THE FRONT AND BACK OF THE DWELLING.
 PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7
 3.PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. NEC 220; FBC RE E3602.2
 4.SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE
 INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG
 THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET
 FROM A RECEPTACLE OUTLET. PROVIDE CORRECTION. NEC
 210.52; FBC RE E3901.2.1
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER
 561-805-6742
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-04-06 Cont ID  
Sent By tklarge Date 2020-04-06 Time 08:24 Rev Time 0.00
Received By tklarge Date 2020-04-06 Time 08:24 Sent To  
Notes
2020-04-06 08:25:53A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A
 CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE
 COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS
 WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-04-07 Cont ID  
Sent By fmittner Date 2020-04-07 Time 11:13 Rev Time 0.00
Received By fmittner Date 2020-04-07 Time 11:13 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-03-19 Cont ID  
Sent By fmittner Date 2020-03-19 Time 16:37 Rev Time 0.00
Received By fmittner Date 2020-03-19 Time 16:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-04-07 Time   Rev Time 0.00
Received By ccarvaja Date 2020-04-04 Time 13:34 Sent To  
Notes
2020-04-04 14:56:20SENT TO R03

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-03-30 Cont ID  
Sent By ppetty Date 2020-03-30 Time 09:55 Rev Time 0.00
Received By ppetty Date 2020-03-18 Time 15:05 Sent To  
Notes
2020-03-18 15:05:40R35

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-04-07 Cont ID  
Sent By ccole Date 2020-04-07 Time 12:40 Rev Time 0.00
Received By ccole Date 2020-04-07 Time 12:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-03-26 Cont ID  
Sent By medwards Date 2020-03-24 Time 13:16 Rev Time 0.00
Received By medwards Date 2020-03-26 Time 16:01 Sent To  
Notes
2020-03-26 16:04:39MR. PAINE SENT A LETTER CLARIFYING THE SCOPE OF WORK IN
 THIS SUNROOM. IT WAS AN EXISTING CONDITIONED SUNROOM
 THAT THEY ARE ADDING A LAUNDRY ROOM AND BATHROOM IN.
 THIS WILL NEED A MECHANICAL PERMIT.
2020-03-24 13:17:161ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20030880
  
 CODES IN EFFECT:
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE ENERGY CALCULATION FOR THE ENCLOSED
 ROOM. SEE: FBC FS 107.2.1
  
 2) HOW ARE YOU GOING TO CONDITION THIS NEWLY ENCLOSED
 ROOM? FBC EC 101.5.1.1.2 SIMULATED PERFORMANCE
 ALTERNATIVE. AN ACCURATELY COMPLETED RESIDENTIAL
 BUILDING FORM R405 (GENERATED BY COMMISSION APPROVED
 SOFTWARE) SHALL BE SUBMITTED TO THE BUILDING OFFICIAL
 TO DEMONSTRATE CODE COMPLIANCE BY SECTION 405.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-04-06 Cont ID  
Sent By tklarge Date 2020-04-06 Time 08:24 Rev Time 0.00
Received By tklarge Date 2020-04-06 Time 08:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-03-26 Cont ID  
Sent By ccole Date 2020-03-26 Time 17:49 Rev Time 0.00
Received By ccole Date 2020-03-26 Time 16:06 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-04-07 Cont ID  
Sent By fmittner Date 2020-04-07 Time 11:13 Rev Time 0.00
Received By fmittner Date 2020-04-07 Time 11:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-03-19 Cont ID  
Sent By fmittner Date 2020-03-19 Time 16:37 Rev Time 0.00
Received By fmittner Date 2020-03-19 Time 16:37 Sent To  
Notes
***NONE***