Plan Review Stops For Permit 20030875 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-06-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-06-15 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-06-15 |
Time |
08:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-05-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-11 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-11 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-30 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-30 |
Time |
14:11 |
Sent To |
|
|
Notes |
2020-03-30 14:29:34 | SOLAR PANELS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) DRAWINGS NEED TO BE SIGNED AND SEALED BY AN | | ARCHITECT OR ENGINEER. | | 2) PLEASE CLEARLY SHOW THE SOLAR PANEL LOCATION ON THE | | ROOF, DIMENSIONS OF PANELS, DIMENSIONS FROM ROOF EDGE | | OR VALLEY. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-05-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-05-08 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-05-08 |
Time |
14:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-03-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-03-26 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-03-26 |
Time |
14:40 |
Sent To |
|
|
Notes |
2020-03-26 17:58:42 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) VALUE IS LOW FOR THIS SIZE SYSTEM. (SYSTEM THIS SIZE | | IS $26,000) | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | 2) SHOW HOW PLAN MEETS THE REQUIREMENTS OF 705.12 | | | | 705.12 (D)(2)(3) (B) WHERE TWO SOURCES, ONE A UTILITY | | AND THE OTHER AN INVERTER, ARE LOCATED AT OPPOSITE ENDS | | OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT | | OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE | | RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR | | SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE | | BUSBAR. THE BUSBAR SHALL BE SIZED FOR THE LOADS | | CONNECTED IN ACCORDANCE WITH ARTICLE 220 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2020-03-19 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2020-03-19 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-06-25 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-06-02 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-05-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-11 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-04-30 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-03-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-30 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-18 |
Time |
08:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-06-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-06-15 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-06-15 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-05-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-11 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-11 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-03-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-30 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-30 |
Time |
14:30 |
Sent To |
|
|
Notes |
2020-03-30 14:30:36 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2020-06-25 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-06-25 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-06-25 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2020-05-05 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-05-05 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-05-05 |
Time |
|
Sent To |
|
|
Notes |
2020-05-05 16:41:39 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) IT IS NOT CLEAR IN THE PLANS IF THE SOLAR PANELS | | ARE TO BE MOUNTED ON A FLAT OR SLOPED ROOF. AERIAL OF | | THE PROPERTY INDICATES THAT THE SOLAR PANELS WILL BE | | LOCATED ON A FLAT ROOFED BUILDING; HOWEVER, A DETAIL | | PROVIDED IN THE PLAN SET INDICATES THAT THE ROOF IS | | SLOPED. PLEASE CLARIFY. | | | | 2.) IN ADDITION TO THE DETAIL OF THE SOLAR PANELS, | | THERE SHOULD BE A DETAIL SHOWING THE OUTLINE OF THE | | PANELS AS TO BE INSTALLED ON THE ROOFTOP OF THE | | EXISTING BUILDING. | | | | 3.) MOUNTING OF THE PANELS SHALL BE CONSISTENT WITH THE | | REQUIREMENTS IN ZLDR S.94-309(I)(4). | | | | | | NOTES: | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: SF7-C4 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
hdanfort |
Date |
2020-03-19 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
hmtribou |
Date |
2020-03-19 |
Time |
16:12 |
Sent To |
|
|
Notes |
2020-03-19 16:13:36 | INDICATE LOCATION OF SOLAR PANEL COLLECTORS ON SITE | | PLAN AND IF ROOF IS FLAT OR SLOPED. |
|
|