Plan Review Details - Permit 20030797
Plan Review Stops For Permit 20030797 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-19 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-19 |
Time |
10:32 |
Sent To |
|
|
Notes |
2020-03-19 10:35:07 | 03/19/2020 RECEIVED E-MAIL FROM BRITNI. THEY ARE NOT | | GOING TO USE THE MODIFIED SYSTEM. SEE BELOW: | | | | | | GOOD MORNING, | | I SPOKE WITH THE HOMEOWNER YESTERDAY AND WE ARE GOING | | TO GO AHEAD AND NOT DO THE MODIFIED SYSTEM FOR THE TILE | | UNDERLAYMENT. WE ARE GOING TO GO BACK TO USING JUST THE | | 90# ROLL ROOFING ON TOP OF THE 30# FELT. | | PLEASE LET ME KNOW IF YOU NEED ANY ADDITIONAL | | INFORMATION FOR THIS CHANGE. | | THANKS FOR ALL OF YOUR HELP :) | | BRITNI | | STORM ROOFING, INC. | | 1340 53RD STREET, SUITE 8 | | WEST PALM BEACH, FL 33407 | | 561-689-0268 | | 561-845-9182 FAX | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-19 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-19 |
Time |
08:38 |
Sent To |
|
|
Notes |
2020-03-19 08:58:43 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 1- ROOFING UNDERLAYMENT FLORIDA PRODUCT APPROVAL | | FL511288-R17 SUBMITTED: | | CLEARLY MARK WHICH MAXIMUM DESIGN PRESSURES ASSEMBLY | | FROM SEC. 5.6.3 OF PRODUCT APPROVAL IS GOING TO BE | | USED. OR IF USING THE FRSA/TRI APRIL 2012 (04-12) | | REVISED EDITION, THEN PROVIDE COMPLETE INFORRMATION | | SHOWING THE DETERMINATION OF DESIGN WIND LOADS AND | | UNDERLAYMENT FASTENING AS REQUIRED BY SEC. 5.6.3 OF | | PRODUCT APPROVAL SUBMITTED. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | RESPONSE: | | SELECTED SYSTEM #10 ON PAGE 7 OF 10 OF FLORIDA PRODUCT | | APPROVAL SUBMITTED HAS A MAXIMUM DESIGN PRESSURE OF | | -67.5 PSF. ACCORDING TO SEC. 5.6.3.2 ON PAGE 7 OF 10 OF | | PRODUCT APPROVAL SUBMITTED THIS ASSEMBLY CAN NOT BE | | USED. FOR MECHANICALLY ATTACHED BASED SHEET THE MAXIMUM | | DESIGN PRESSURE FOR THE SELECTED ASSEMBLY SHALL MEET OR | | EXCEED THAT REQUIRED UNDER FRSA/TRI APPENDIX A, TABLE | | 1A. SELECTED ASSEMBLY DOESN'T MEET THAT DESIGN | | PRESSURE. PLEASE SELECT ANOTHER ASSEMBLY OR | | ALTERNATIVELY, PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS AS REQUIRED ON SEC. 5.6.3.2 OF PRODUCT | | PROPOSAL SUBMITTED. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-17 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-17 |
Time |
14:12 |
Sent To |
|
|
Notes |
2020-03-19 08:46:49 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- ROOFING UNDERLAYMENT FLORIDA PRODUCT APPROVAL | | FL511288-R17 SUBMITTED: | | CLEARLY MARK WHICH MAXIMUM DESIGN PRESSURES ASSEMBLY | | FROM SEC. 5.6.3 OF PRODUCT APPROVAL IS GOING TO BE | | USED. OR IF USING THE FRSA/TRI APRIL 2012 (04-12) | | REVISED EDITION, THEN PROVIDE COMPLETE INFORMATION | | SHOWING THE DETERMINATION OF DESIGN WIND LOADS AND | | UNDERLAYMENT FASTENING AS REQUIRED BY SEC. 5.6.3 OF | | PRODUCT APPROVAL SUBMITTED. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-19 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-19 |
Time |
10:30 |
Sent To |
I |
|
Notes |
2020-03-19 10:32:25 | 03/19/2020 RECEIVED E-MAIL FROM BRITNI. THEY ARE NOT | | GOING TO USE THE MODIFIED SYSTEM. SEE BELOW: | | | | | | GOOD MORNING, | | I SPOKE WITH THE HOMEOWNER YESTERDAY AND WE ARE GOING | | TO GO AHEAD AND NOT DO THE MODIFIED SYSTEM FOR THE TILE | | UNDERLAYMENT. WE ARE GOING TO GO BACK TO USING JUST THE | | 90# ROLL ROOFING ON TOP OF THE 30# FELT. | | PLEASE LET ME KNOW IF YOU NEED ANY ADDITIONAL | | INFORMATION FOR THIS CHANGE. | | THANKS FOR ALL OF YOUR HELP :) | | BRITNI | | STORM ROOFING, INC. | | 1340 53RD STREET, SUITE 8 | | WEST PALM BEACH, FL 33407 | | 561-689-0268 | | 561-845-9182 FAX | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-19 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-19 |
Time |
08:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-03-17 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-03-16 |
Time |
16:28 |
Sent To |
|
|
Notes |
|
|
|