2020-03-19 10:35:0703/19/2020 RECEIVED E-MAIL FROM BRITNI. THEY ARE NOT
 GOING TO USE THE MODIFIED SYSTEM. SEE BELOW:
  
  
 GOOD MORNING,
 I SPOKE WITH THE HOMEOWNER YESTERDAY AND WE ARE GOING
 TO GO AHEAD AND NOT DO THE MODIFIED SYSTEM FOR THE TILE
 UNDERLAYMENT. WE ARE GOING TO GO BACK TO USING JUST THE
 90# ROLL ROOFING ON TOP OF THE 30# FELT.
 PLEASE LET ME KNOW IF YOU NEED ANY ADDITIONAL
 INFORMATION FOR THIS CHANGE.
 THANKS FOR ALL OF YOUR HELP :)
 BRITNI
 STORM ROOFING, INC.
 1340 53RD STREET, SUITE 8
 WEST PALM BEACH, FL 33407
 561-689-0268
 561-845-9182 FAX
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-03-19 Cont ID  
Sent By jgomez Date 2020-03-19 Time 08:57 Rev Time 0.00
Received By jgomez Date 2020-03-19 Time 08:38 Sent To  
Notes
2020-03-19 08:58:43RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 1- ROOFING UNDERLAYMENT FLORIDA PRODUCT APPROVAL
 FL511288-R17 SUBMITTED:
 CLEARLY MARK WHICH MAXIMUM DESIGN PRESSURES ASSEMBLY
 FROM SEC. 5.6.3 OF PRODUCT APPROVAL IS GOING TO BE
 USED. OR IF USING THE FRSA/TRI APRIL 2012 (04-12)
 REVISED EDITION, THEN PROVIDE COMPLETE INFORRMATION
 SHOWING THE DETERMINATION OF DESIGN WIND LOADS AND
 UNDERLAYMENT FASTENING AS REQUIRED BY SEC. 5.6.3 OF
 PRODUCT APPROVAL SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 SELECTED SYSTEM #10 ON PAGE 7 OF 10 OF FLORIDA PRODUCT
 APPROVAL SUBMITTED HAS A MAXIMUM DESIGN PRESSURE OF
 -67.5 PSF. ACCORDING TO SEC. 5.6.3.2 ON PAGE 7 OF 10 OF
 PRODUCT APPROVAL SUBMITTED THIS ASSEMBLY CAN NOT BE
 USED. FOR MECHANICALLY ATTACHED BASED SHEET THE MAXIMUM
 DESIGN PRESSURE FOR THE SELECTED ASSEMBLY SHALL MEET OR
 EXCEED THAT REQUIRED UNDER FRSA/TRI APPENDIX A, TABLE
 1A. SELECTED ASSEMBLY DOESN'T MEET THAT DESIGN
 PRESSURE. PLEASE SELECT ANOTHER ASSEMBLY OR
 ALTERNATIVELY, PROVIDE SIGNED AND SEALED RAS 117
 CALCULATIONS AS REQUIRED ON SEC. 5.6.3.2 OF PRODUCT
 PROPOSAL SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-19 Cont ID  
Sent By jgomez Date 2020-03-17 Time 08:46 Rev Time 0.00
Received By jgomez Date 2020-03-17 Time 14:12 Sent To  
Notes
2020-03-19 08:46:49RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ROOFING UNDERLAYMENT FLORIDA PRODUCT APPROVAL
 FL511288-R17 SUBMITTED:
 CLEARLY MARK WHICH MAXIMUM DESIGN PRESSURES ASSEMBLY
 FROM SEC. 5.6.3 OF PRODUCT APPROVAL IS GOING TO BE
 USED. OR IF USING THE FRSA/TRI APRIL 2012 (04-12)
 REVISED EDITION, THEN PROVIDE COMPLETE INFORMATION
 SHOWING THE DETERMINATION OF DESIGN WIND LOADS AND
 UNDERLAYMENT FASTENING AS REQUIRED BY SEC. 5.6.3 OF
 PRODUCT APPROVAL SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-19 Cont ID  
Sent By jgomez Date 2020-03-19 Time 10:56 Rev Time 0.00
Received By jgomez Date 2020-03-19 Time 10:30 Sent To I
Notes
2020-03-19 10:32:2503/19/2020 RECEIVED E-MAIL FROM BRITNI. THEY ARE NOT
 GOING TO USE THE MODIFIED SYSTEM. SEE BELOW:
  
  
 GOOD MORNING,
 I SPOKE WITH THE HOMEOWNER YESTERDAY AND WE ARE GOING
 TO GO AHEAD AND NOT DO THE MODIFIED SYSTEM FOR THE TILE
 UNDERLAYMENT. WE ARE GOING TO GO BACK TO USING JUST THE
 90# ROLL ROOFING ON TOP OF THE 30# FELT.
 PLEASE LET ME KNOW IF YOU NEED ANY ADDITIONAL
 INFORMATION FOR THIS CHANGE.
 THANKS FOR ALL OF YOUR HELP :)
 BRITNI
 STORM ROOFING, INC.
 1340 53RD STREET, SUITE 8
 WEST PALM BEACH, FL 33407
 561-689-0268
 561-845-9182 FAX
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-19 Cont ID  
Sent By jgomez Date 2020-03-19 Time 09:40 Rev Time 0.00
Received By jgomez Date 2020-03-19 Time 08:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING