Plan Review Stops For Permit 20030721 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-05-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-15 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-15 |
Time |
08:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2020-04-20 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2020-04-20 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-04-17 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-04 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-06-04 |
Time |
07:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-05-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-05-13 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-05-13 |
Time |
14:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-04-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-04-10 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-04-08 |
Time |
09:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-04-08 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-04-08 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-04-08 |
Time |
15:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2020-05-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-05-20 |
Time |
08:14 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-05-20 |
Time |
07:11 |
Sent To |
|
|
Notes |
2020-05-20 08:30:45 | PER THE ENGINEER'S NARRATIVE, THE SCOPE OF GAS PIPING | | WORK AND INSTALLATION OF THE POOL HEATERS HAS BEEN | | REMOVED FROM THIS REVISION. I HAVE VOIDED OUT SHEET | | P-5.8 (REVISION-1 OWNER REQUESTED CHANGES 3-06-2020) | | CCOLE- 5/20/2020 | | SEPARATE PERMIT REQUIRED FOR GAS PIPING AND POOL HEATER | | INSTALLATIONS- SECTION 107.2.1 WPB. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-04-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2020-04-10 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2020-04-10 |
Time |
08:51 |
Sent To |
|
|
Notes |
2020-04-10 08:58:07 | A NEW GAS PLAN HAS BEEN SUBMITTED FOR REVIEW. | | 1) ) SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | INSTALLATION INSTRUCTIONS FOR THE PRESSURE REGULATORS. | | REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING | | SHALL BE APPROVED FOR OUTDOOR INSTALLATION. IDENTIFY ON | | THE SPECIFICATION SHEETS WHICH MODEL REGULATOR IS BEING | | INSTALLED AND THE ORIFICE SIZE TO ENSURE THE REGULATOR | | CAN ACCOMMODATE THE BTU LOAD THROUGH THE REGULATOR.2017 | | FGC SEC.410.1, 2017 FBC-RES. SEC. G2421.1. | | 2) WHERE CONNECTED TO RIGID PIPING, A UNION SHALL BE | | INSTALLED WITHIN 1 FOOT OF EITHER SIDE OF THE MP | | REGULATOR. 2017 FBC-FUEL GAS SEC.410.2 (7). | | 3) SEDIMENT TRAPS ARE REQUIRED AT THE POOL HEATERS PER | | 2017 FBC-GAS SEC. 408.4. | | 4) SHOW THE TYPE AND SIZE OF THE PIPE AT THE OULET OF | | THE GAS METER. | | 5) SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR THE POOL | | HEATERS. PROVIDE VERIFICATION & CALCULATIONS AS TO HOW | | THE REQUIREMENTS ARE BEING MET. PROVIDE THE CODE | | SECTIONS FROM THE GAS CODE THAT YOU ARE USING IN THE | | DESIGN OF THE COMBUSTION AIR REQUIREMENTS PER THE 2017 | | FBC-FUEL GAS CODE SEC.304.1. | | 6) SUBMIT TWO COPIES OF A DETAIL SHOWING THE TYPE OF | | VENT, LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE | | THE ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) FOR | | THE POOL HEATERS PER 2017 FBC-FUEL GAS SECS. 502 THRU | | 505. | | 7) SHT.P-5.8 REFERS TO TABLE 402.4 (5) WHICH IS FOR | | SCH. 40 METALLIC PIPE AT 2 PSI. THE GAS RISER ALSO | | SHOWS PE PIPE BUT THERE IS NO SIZING TABLE REFERENCED. | | SUBMIT THE SIZING TABLE BEING USED FOR THE PE PIPE. | | 8) SUBMIT TWO COPIES OF THE MANUFACTURER?S | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND | | 301.3. GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT | | SHALL BE ONSITE AT THE TIME OF INSPECTION. FGC | | SEC.305.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-06-04 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-05-29 |
Time |
10:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-05-20 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-05-07 |
Time |
11:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-05-07 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-05-07 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-04-07 |
Time |
15:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-02 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-06-02 |
Time |
13:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-05-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-05-11 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-05-11 |
Time |
14:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-04-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-04-08 |
Time |
18:07 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-04-08 |
Time |
16:25 |
Sent To |
|
|
Notes |
2020-04-08 18:32:00 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #20030721 | | 4/8/20 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE GREASE DUCT INSTALLATION DETAILS: | | | | A) TYPE OF DUCT MATERIAL AND FABRICATION- SECTIONS | | 506.3.1 THROUGH 506..3.2.3 FBC M. | | B) DUCT DIMENSIONS- 506.1 | | C) DUCT SIZING AND VELOCITY CALCULATIONS- 506.3.4 | | | | 2) SHOW THE LOCATIONS OF REQUIRED CLEANOUTS AT 20' | | VERTICAL SPACING AND HOW ACCESS WILL BE PROVIDED- | | SECTION 506.3.8(2) | | | | A) PROVIDE A CLEANOUT DETAIL- 506.3.8(3,4,5,6,7) | | | | 3) SHOW THE LOCATION OF THE EXHAUST FAN AND PROVIDE A | | FAN SCHEDULE- 506.5.1 THROUGH 506.5.5 | | | | 4) PROVIDE ENGINEERING FOR ANCHORING AND SUPPORTING THE | | ROOF DUCT AND FAN. INCLUDE DETAILS INDICATING THE | | CLEARANCE BETWEEN THE DUCT AND THE ROOF SURFACE- | | SECTION 301.15 AND 1510.10 FBC B. | | | | 5) SHEETS M-3,1, 4.1, 4.2, 5.1, 5.2, 5.3, 5.4, 6.1, & | | 6.2 ARE INDICATED IN THE MEP NARRATIVE BUT NOT UPLOADED | | FOR REVIEW- SECTION 107.2.1 WPB | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-06-02 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-06-02 |
Time |
12:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-05-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-05-20 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-05-20 |
Time |
07:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-04-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2020-04-10 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2020-04-08 |
Time |
08:54 |
Sent To |
|
|
Notes |
2020-04-10 08:51:17 | A NEW GAS PLAN HAS BEEN SUBMITTED FOR REVIEW. | | 1) ) SUBMIT MANUFACTURER?S SPECIFICATIONS AND | | INSTALLATION INSTRUCTIONS FOR THE PRESSURE REGULATORS. | | REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING | | SHALL BE APPROVED FOR OUTDOOR INSTALLATION. IDENTIFY ON | | THE SPECIFICATION SHEETS WHICH MODEL REGULATOR IS BEING | | INSTALLED AND THE ORIFICE SIZE TO ENSURE THE REGULATOR | | CAN ACCOMMODATE THE BTU LOAD THROUGH THE REGULATOR.2017 | | FGC SEC.410.1, 2017 FBC-RES. SEC. G2421.1. | | 2) WHERE CONNECTED TO RIGID PIPING, A UNION SHALL BE | | INSTALLED WITHIN 1 FOOT OF EITHER SIDE OF THE MP | | REGULATOR. 2017 FBC-FUEL GAS SEC.410.2 (7). | | 3) SEDIMENT TRAPS ARE REQUIRED AT THE POOL HEATERS PER | | 2017 FBC-GAS SEC. 408.4. | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-06-02 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-05-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-05-11 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-05-11 |
Time |
14:41 |
Sent To |
|
|
Notes |
2020-05-11 15:44:22 | PLEASE PROVIDE DIGITAL SIGNATURES AND SEALS ON THE | | FOLLOWING SHEETS- | | M-2.1B; M-5.4; E-3.5; E-6.1; P2.1B | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-04-08 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-04-08 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-04-08 |
Time |
13:25 |
Sent To |
|
|
Notes |
2020-04-08 13:25:47 | ALL SHEETS THIS SUBMISSION GOOD. ANY NEW SUBMISSIONS | | WILL NEED TO BE CHECKED. WPB FBC 105.1 | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
1 |
Status |
N |
Date |
2020-04-20 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-04-20 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-04-20 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-04-30 |
|
|
Cont ID |
|
Sent By |
hdanfort |
Date |
2020-04-30 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2020-04-30 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|