Plan Review Details - Permit 20030655
Plan Review Stops For Permit 20030655
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2020-03-20 Cont ID  
Sent By rmcdouga Date 2020-03-20 Time 13:59 Rev Time 0.00
Received By rmcdouga Date 2020-03-20 Time 13:59 Sent To  
Notes
2020-03-20 14:07:08LETTER WAS SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-04-07 Cont ID  
Sent By ccole Date 2020-04-07 Time 11:16 Rev Time 0.00
Received By ccole Date 2020-04-07 Time 11:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-03-20 Cont ID  
Sent By rmcdouga Date 2020-03-20 Time 14:33 Rev Time 0.00
Received By rmcdouga Date 2020-03-20 Time 14:22 Sent To  
Notes
2020-03-20 14:33:25APPROVED WITH EXCEPTIONS
  
 BUILDING PROVISO - DEFERRED SUBMITTALS FBC 107.3.4.1
 1) SPECIFY THE TYPE OF FLOORING THAT WILL BE INSTALLED
 AND SUBMIT (2) SETS OF THE TEST REPORTS FOR FBC 1207.2
 AIR-BORNE SOUND, FBC 1207.3 ASTM E 90-04,
 STRUCTURE-BORNE SOUND, ASTM E 492-09 AND FBC 603.1
 FLAME SPREAD, ASTM E 84-09 FOR APPROVAL BEFORE
 INSTALLATION.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-03-30 Cont ID  
Sent By ppetty Date 2020-03-30 Time 10:28 Rev Time 0.00
Received By ppetty Date 2020-03-30 Time 10:28 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-04-06 Cont ID  
Sent By pleduc Date 2020-04-06 Time   Rev Time 0.00
Received By pleduc Date 2020-04-06 Time 10:28 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-03-16 Cont ID  
Sent By pleduc Date 2020-03-16 Time   Rev Time 0.00
Received By pleduc Date 2020-03-16 Time 14:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-04-07 Time   Rev Time 0.00
Received By ccarvaja Date 2020-04-04 Time 14:41 Sent To  
Notes
2020-04-04 14:48:45ROUTED TO B03

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-03-30 Cont ID  
Sent By ppetty Date 2020-03-30 Time 10:28 Rev Time 0.00
Received By ppetty Date 2020-03-13 Time 16:28 Sent To  
Notes
2020-03-13 16:28:48B03

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-04-07 Cont ID  
Sent By ccole Date 2020-04-07 Time 11:16 Rev Time 0.00
Received By ccole Date 2020-04-07 Time 11:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2020-03-20 Cont ID  
Sent By rmcdouga Date 2020-03-20 Time 14:58 Rev Time 0.00
Received By rmcdouga Date 2020-03-20 Time 14:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-04-07 Cont ID  
Sent By ccole Date 2020-04-07 Time 11:16 Rev Time 0.00
Received By ccole Date 2020-04-07 Time 11:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-03-27 Cont ID  
Sent By ccole Date 2020-03-27 Time 11:28 Rev Time 0.00
Received By ccole Date 2020-03-27 Time 11:15 Sent To  
Notes
2020-03-27 11:55:441ST REVIEW FBC-2017 PLUMBING
 PERMIT
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-1, MP-1- TUB BOX INFILL: PROVIDE A UL TESTED
 AND APPROVED FIRESTOPPING ASSEMBLY FOR THE DRAIN PIPE
 PENTRATION THROUGH THE FIRE-RATED FLOOR/CEILING
 ASSEMBLY- SECTION 714.4.1 FBC B. THE PIPE SHALL ALSO BE
 PROTECTED FROM CORROSION BY SHEATHING OR WRAPPING IN
 ACCORDANCE WITH SECTION 305.1 FBC P.
  
 2) MP-1: PLEASE UPDATE THE CODE COMPLIANCE DATA TO
 INDICATE THE FLORIDA PLUMBING CODE SIXTH EDITION 2017,
 AND REMOVE THE FBC RES P2709.1 REFERENCE FROM THE
 SHOWER DETAIL. THIS PROJECT IS NOT GOVERNED BY THE
 SINGLE-FAMILY RESIDENTIAL CODE BECAUSE IT A MULTI-STORY
 R-2 OCCUPANCY.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  