Plan Review Details - Permit 20030636
Plan Review Stops For Permit 20030636
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2020-03-27 Cont ID  
Sent By cpuell Date 2020-03-27 Time 14:13 Rev Time 0.00
Received By cpuell Date 2020-03-27 Time 14:13 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2020-03-26 Cont ID  
Sent By rmcphers Date 2020-03-26 Time 13:43 Rev Time 0.00
Received By rmcphers Date 2020-03-26 Time 13:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-04-10 Cont ID  
Sent By rmcphers Date 2020-04-10 Time 11:53 Rev Time 0.00
Received By rmcphers Date 2020-04-10 Time 11:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-26 Cont ID  
Sent By rmcphers Date 2020-03-26 Time 13:42 Rev Time 0.00
Received By rmcphers Date 2020-03-26 Time 13:05 Sent To  
Notes
2020-03-26 13:42:46CREATE SHELL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) WALL ADDED TO SEPARATE TWO UNITS. PLEASE SHOW
 ADJACENT TENANT SPACE MEANS OF EGRESS TO COMPLY WITH
 FBC CHAPTER 10 (I ONLY SEE 1 DOOR FOR THE ADJACENT
 SPACE)
 2) ARCHITECTURAL DRAWINGS DO NOT SHOW IN "ADOBE" AS
 ELECTRONICALLY SIGNED. DRAWINGS NEED TO BE
 ELECTRONICALLY SIGNED TO BE USED IN ELECTRONIC PLAN
 REVIEW.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-03-26 Cont ID  
Sent By jleahy Date 2020-03-26 Time 13:45 Rev Time 0.00
Received By jleahy Date 2020-03-26 Time 13:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-04-10 Cont ID  
Sent By pleduc Date 2020-04-10 Time   Rev Time 0.00
Received By pleduc Date 2020-04-10 Time 09:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-03-25 Cont ID  
Sent By pleduc Date 2020-03-25 Time   Rev Time 0.00
Received By pleduc Date 2020-03-25 Time 09:42 Sent To  
Notes
2020-03-25 10:03:16THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-04-13 Time   Rev Time 0.00
Received By lmarchan Date 2020-04-09 Time 10:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-03 Cont ID  
Sent By lmarchan Date 2020-04-03 Time 11:31 Rev Time 0.00
Received By lmarchan Date 2020-03-24 Time 14:48 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-03-24 Cont ID  
Sent By lmarchan Date 2020-03-24 Time 14:00 Rev Time 0.00
Received By lmarchan Date 2020-03-24 Time 14:00 Sent To  
Notes
2020-03-24 14:00:50SEE UPLOADED EMAIL FROM IMPACT FEE OFFICE. LEM

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-04-13 Cont ID  
Sent By jpearson Date 2020-04-13 Time 15:36 Rev Time 0.00
Received By jpearson Date 2020-04-13 Time 15:29 Sent To  
Notes
2020-04-13 15:29:18REVIEWED BY JERRY SMITH.

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-03-26 Cont ID  
Sent By jbaker Date 2020-03-26 Time 08:07 Rev Time 0.00
Received By shill Date 2020-03-26 Time 07:19 Sent To  
Notes
2020-03-26 08:08:00PLUMBING:
  
 FAILED
  
 COMMENTS:
  
 1. 2017 FBC 107.2.1 PROVIDE PIPING MATERIAL
 SPECIFICATION AND INSULATION SPECIFICATION AND AMOUNT
 OF INSULATION.
  
  
 PROVIDE A COMMENT/RESPONSE LETTER WITH YOUR RESUBMITTAL
 FOR EXPEDITIOUS REVIEW.
  
  
 THANK YOU,
  
  
 JIM BAKER, P.E. PX, LEED AP
 [email protected]
  
  
 REVIEWED REMOTELY BY JAMES BAKER, PE
 PX3997, PE77268
 561-805-6724
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-04-10 Cont ID  
Sent By rmcphers Date 2020-04-10 Time 11:53 Rev Time 0.00
Received By rmcphers Date 2020-04-10 Time 11:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-03-26 Cont ID  
Sent By rmcphers Date 2020-03-26 Time 13:46 Rev Time 0.00
Received By rmcphers Date 2020-03-26 Time 13:46 Sent To  
Notes
2020-03-26 13:46:38ARCHITECTURAL DRAWINGS DO NOT SHOW IN "ADOBE" AS
 ELECTRONICALLY SIGNED.

Review Stop Z ZONING
Rev No 1 Status P Date 2020-04-03 Cont ID  
Sent By eschneid Date 2020-04-03 Time 10:32 Rev Time 0.50
Received By eschneid Date 2020-04-03 Time 09:53 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved