Plan Review Details - Permit 20030607
Plan Review Stops For Permit 20030607
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-07-06 Cont ID  
Sent By pvalenti Date 2020-07-06 Time 08:49 Rev Time 0.00
Received By pvalenti Date 2020-07-06 Time 08:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-04-02 Cont ID  
Sent By jbrooks Date 2020-04-02 Time 13:04 Rev Time 0.00
Received By jbrooks Date 2020-04-02 Time 13:04 Sent To  
Notes
2020-04-02 13:04:38JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561)
 805-6724
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 1. PLEASE ADDRESS ZONING COMMENTS.
 2. FBC B 107.2.1. SUBMITTED DRAWINGS INDICATE 3 SHEETS;
 SHEET 1 OF 3 SHEETS MISSING, PROVIDE TWO SETS.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-07-05 Cont ID  
Sent By jleahy Date 2020-07-05 Time 14:54 Rev Time 0.00
Received By jleahy Date 2020-07-05 Time 14:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-04-09 Cont ID  
Sent By jpearson Date 2020-04-09 Time 07:56 Rev Time 0.00
Received By jpearson Date 2020-04-07 Time 07:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-07-15 Cont ID  
Sent By lmarchan Date 2020-07-15 Time 13:33 Rev Time 0.00
Received By lmarchan Date 2020-06-30 Time 15:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-04-02 Cont ID  
Sent By jbrooks Date 2020-04-09 Time 13:04 Rev Time 0.00
Received By jbrooks Date 2020-03-12 Time 11:02 Sent To  
Notes
2020-04-02 18:45:20ROUTED TO ELECTRICAL
2020-04-01 10:40:58BLDG MISC 2
2020-03-13 11:02:28ROUTED TO ZONING INBOX

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-07-06 Cont ID  
Sent By pvalenti Date 2020-07-06 Time 08:49 Rev Time 0.00
Received By pvalenti Date 2020-07-06 Time 06:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-04-08 Cont ID  
Sent By jgomez Date 2020-04-08 Time 09:25 Rev Time 0.00
Received By jgomez Date 2020-04-08 Time 09:24 Sent To  
Notes
2020-04-08 09:33:59ENGINEER'S ORIGINAL SEAL/SIGNATURE IN CITY'S HARD COPY
 SUBMITTAL.
 IF REVISED, FUTURE SUBMITTALS WILL NEED TO BE REVIEWED.
 SINCE THIS APPLICATION WAS CONVERTED TO DIGITAL,
 ENGINEER'S DIGITAL SIGNATURE VIA CITY'S PROJECTDOX
 SYSTEM IS RECOMMENDED. JG.
  
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 2020-07-15 Cont ID  
Sent By eschneid Date 2020-07-15 Time 11:59 Rev Time 0.25
Received By eschneid Date 2020-07-15 Time 11:57 Sent To  
Notes
2020-07-15 11:59:56FAILED
  
 THIS IS A SIGN TYPE 1A - FASCIA IDENTITY SIGN
  
 1) UPDATED COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA PERMIT A MAXIMUM SIGN PANEL (THE DECK CABINET)
 AND LETTER HEIGHT OF 18 INCHES FOR A FASCIA IDENTITY
 SIGN UNLESS CITYPLACE RETAIL IS GRANTED A WAIVER II
 (MINOR PLANNED DEVELOPMENT AMENDMENT). THE LETTER FROM
 CITYPLACE RETAIL DOES NOT APPROVE THE WAIVER II. A
 WAIVER II MUST BE SUBMITTED TO THE PLANNING DIVISION AS
 A MINOR PLANNED DEVELOPMENT AMENDMENT. CURRENTLY, THE
 WAIVER II MAY INCREASE THE SIGNS DIMENSION BY UP TO 25
 PERCENT, SO THE SIGN PANEL (THE DECK CABINET) AND
 LETTER HEIGHT COULD BE UP TO 22.5 INCHES. SINCE THE
 PROPOSED SIGN IS 23 INCHES IN HEIGHT, THIS DIMENSION IS
 CURRENTLY NOT PERMITTED. HOWEVER, CITYPLACE RETAIL HAS
 AN AMENDMENT TO THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA SUBMITTED THAT, IF APPROVED IN SEPTEMBER,
 WOULD PERMIT THE WAIVER II TO ALLOW SIGN TYPE 1A -
 FASCIA IDENTITY SIGN TO INCREASE IN DIMENSION UP TO
 50%. YOU CAN EITHER REDUCE THE SIGN SIZE NOW AND
 CITYPLACE RETAIL APPLIES FOR A WAIVER II UNDER THE
 CURRENT REGULATIONS OR WAIT FOR THE AMENDED REGULATIONS
 TO PASS AND GET THE LARGER DIMENSION AFTER A WAIVER II
 WITH THE APPROVAL OF A FUTURE WAIVER II.
  
 2) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE THAT LETTER CHANNELS ARE TO BE STUD
 MOUNTED A MAXIMUM ONE (1) INCH FROM THE WALL. THE
 PROPOSED DESIGN WITH AN ALUMINUM DECK CABINET MOUNTED
 TO THE WALL AND THE CHANNEL LETTERS MOUNTED TO THE
 CABINET IS NOT PERMITTED. PLEASE REFER TO THE ROSEMARY
 SQUARE TENANT SIGN CRITERIA FOR THE REQUIREMENTS
 REGARDING THE USE OF CHANNEL LETTERS VS THE USE OF A
 PANEL DESIGN.
  
 PERMITTED: 88 SF
 PROPOSED: 23.8 SF
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-03-31 Cont ID  
Sent By eschneid Date 2020-03-31 Time 16:07 Rev Time 0.00
Received By eschneid Date 2020-03-31 Time 16:07 Sent To  
Notes
2020-03-31 16:07:55FAILED
  
 1) THE SIGN INCLUDES NOT ONLY THE TD AND THE AMERITRADE
 TEXT, BUT ALSO THE DECK CABINET, WHICH MAKES THE ENTIRE
 SIGN 23.8 SQUARE FEET.
  
 2) THE PROPOSED SIGN IS A FASCIA SIGN IN THE ROSEMARY
 SQUARE TENANT SIGN CRITERIA. FASCIA SIGNS ARE PERMITTED
 ON A CASE-BY-CASE BASIS FOR SINGLE HEIGHT TENANTS
 WITHOUT ARCADES (STOREFRONT TYPE 3). SIGNS PERMITTED ON
 A CASE-BY-CASE BASIS REQUIRE THE APPROVAL OF A WAIVER
 I, WHICH IS WRITTEN APPROVAL FROM CITYPLACE RETAIL ON
 THEIR LETTERHEAD.
  
 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT THE WALL SIGNS (WHICH INCLUDE FASCIA SIGNS) BE
 BALANCED WITHIN THE SIGN SPACE. PLEASE PROVIDE THE
 DIMENSIONS FROM THE SIGN TEXT TO EACH END OF THE DECK
 CABINET. THESE DIMENSIONS MUST BE EQUAL.
  
 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PROHIBIT
 VISIBLE WIRING. THE ELEVATION DRAWING SHOWS VISIBLE
 WIRES RUNNING FROM THE BACK OF EACH LETTER TO THE DECK
 CABINET.
  
 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT
 FASCIA SIGNS TO BE BETWEEN NINE (9) AND TWELVE FEET
 FROM FINISHED GRADE. THE ELEVATION PLAN DOES NOT
 PROVIDE THE HEIGHT OF THE SIGN FROM GRADE. PROVIDE THE
 DIMENSIONS SO THAT STAFF CAN VERIFY THE SIGN PLACEMENT.
  
 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A
 MAXIMUM SIGN PANEL (THE DECK CABINET) AND LETTER HEIGHT
 OF 18 INCHES FOR A FASCIA SIGN UNLESS CITYPLACE RETAIL
 IS GRANTED A WAIVER II (MINOR PLANNED DEVELOPMENT
 AMENDMENT). THE WAIVER II MAY INCREASE THE SIGNS
 DIMENSION BY UP TO 25 PERCENT, SO THE SIGN PANEL (THE
 DECK CABINET) AND LETTER HEIGHT COULD BE UP TO 22.5
 INCHES. NOTE: THE PROPOSED SIGN IS 23 INCHES IN HEIGHT.
  
 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT LETTER CHANNELS ARE TO BE STUD MOUNTED A MAXIMUM
 ONE (1) INCH FROM THE WALL. THE PROPOSED DESIGN WITH A
 DECK CABINET MOUNTED TO THE WALL AND THE CHANNEL
 LETTERS MOUNTED TO THE DECK PANEL DOES IS NOT
 PERMITTED.
  
 8) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE
 STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR
 BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE
 PLANS.
  
 PERMITTED: 88 SF
 PROPOSED: 23.8 SF
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved