Plan Review Details - Permit 20030529
Plan Review Stops For Permit 20030529 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-03-31 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-03-31 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-31 |
Time |
15:45 |
Sent To |
|
|
Notes |
2020-03-31 15:46:58 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE | | PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S. | | SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING: | | BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO | | BE USED. | | AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-03-19 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-19 |
Time |
16:10 |
Sent To |
|
|
Notes |
2020-03-19 16:17:52 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, PLEASE CLARIFY DETAIL TO MEET THE | | REQUIREMENTS NOTED ON ZONING REVIEW NOTES. | | | | NOTE: AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE | | PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S. | | SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING: | | BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO | | BE USED. | | AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-03-19 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-03-19 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-11 |
Time |
13:00 |
Sent To |
|
|
Notes |
2020-03-16 16:48:43 | 3/16 BLDG MISC 2 | 2020-03-12 13:00:45 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-03-31 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-03-31 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-03-31 |
Time |
14:37 |
Sent To |
I |
|
Notes |
2020-03-31 14:38:06 | THE PROPOSED AWNING IS NOT ENCROACHING WITHIN THE SIDE | | SETBACK. | | | | RACHEL FALCONE | | ASSOCIATE PLANNER | | [email protected] | | 561-822-1442 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-03-16 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-03-16 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-03-16 |
Time |
15:08 |
Sent To |
I |
|
Notes |
2020-03-16 15:10:41 | ZONING PLAN REVIEW | | ________________________________________ | | | | DATE OF REVIEW: 03/16/2020 | | ________________________________________ | | | | REVIEW STATUS: FAILED | | ________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. THE PROPOSED AWNING IS ENCROACHING WITHIN THE REAR | | SETBACK OF THE SUBJECT SITE. DUE TO THE AWNING | | CONTAINING POST HOLDING IT FROM THE GROUND IT BECOMES | | PART OF THE PRINCIPAL STRUCTURE. | | | | ________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1442 | | TTY: 800.955.8771 | | E: [email protected] | | | | W: WPB.ORG | | |
|
|
|