Plan Review Stops For Permit 20030509 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2020-04-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-04-24 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-04-24 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2020-03-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-18 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-18 |
Time |
15:42 |
Sent To |
|
|
Notes |
2020-03-18 15:45:05 | ASBESTOS ? PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM | | THE CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-04-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-04-24 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-04-24 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-18 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-18 |
Time |
13:18 |
Sent To |
|
|
Notes |
2020-03-18 15:42:22 | OFFICE BUILD OUT | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) SHOW DOOR MARKED 317 TO COMPLY WITH FBC 1005.7 | | ENCROACHMENTS INTO THE REQUIRED MEANS OF EGRESS WIDTH. | | 2) SHOW GLASS WALLS AND DOORS TO BE SAFETY GLAZING PER | | FBC 2406 | | 3) PLEASE PROVIDE AN EXISTING FLOOR PLAN TO SHOW THE | | EXISTING USE OF THE SPACE. MAY AFFECT EGRESS | | REQUIREMENTS FOR THE BUILDING - FBC EXISTING 1012.4.1 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-04-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-04-01 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-03-31 |
Time |
16:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-04-08 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-04-08 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-04-08 |
Time |
11:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2020-03-13 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-03-13 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-03-13 |
Time |
12:59 |
Sent To |
|
|
Notes |
2020-03-13 13:02:00 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) SHEET A 1.1.1 - NEW DOOR INDICATED AS 317 OPENS INTO | | THE EXIT CORRIDOR AND APPREARS TO ENCROACH ON THE | | REQUIRED EGRESS WIDTH; HOWEVER, THE EXACT DIMESNION OF | | THE EGRESS WIDTH IS NOT PROVIDED. | | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT | | MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A | | CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN, | | UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET: | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | EXISTING BUILDING. | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED | | WIDTH OF THE STAIR LANDING WHEN THE DOOR | | LEAF IS FULLY OPEN. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | 2) SHEET A 2.0.1 - THERE ARE INDICATIONS OF CARD READER | | AND ACCESS CONTROL ON EXIT DOORS. | | | | ALL ACCESS CONTROL SHALL BE UNDER SEPARATE PERMIT AND | | COMPLY WITH NFPA 101, CH. 7 MEANS OF EGRESS AS | | APPLICABLE TO FUNCTION. | | | | PLEASE PROVIDE AN APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-04-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-04-24 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-04-07 |
Time |
09:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-04-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-04-01 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-03-11 |
Time |
15:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2020-03-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-18 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-18 |
Time |
15:56 |
Sent To |
|
|
Notes |
2020-03-18 15:57:17 | MAY NOT BE REQUIRED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2020-03-26 |
|
|
Cont ID |
|
Sent By |
jbaker |
Date |
2020-03-26 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-03-26 |
Time |
07:44 |
Sent To |
|
|
Notes |
2020-03-26 14:00:51 | REVIEWED REMOTELY BY JAMES BAKER, PE | | PX3997, PE77268 | | 561-805-6724 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2020-03-26 |
|
|
Cont ID |
|
Sent By |
jbaker |
Date |
2020-03-26 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-03-26 |
Time |
07:18 |
Sent To |
|
|
Notes |
2020-03-26 07:44:03 | REVIEWED REMOTELY BY JAMES BAKER, PE | | PX3997, PE77268 | | 561-805-6724 | | [email protected] | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-04-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-04-24 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-04-24 |
Time |
15:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-03-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-18 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-18 |
Time |
16:03 |
Sent To |
|
|
Notes |
|
|