Plan Review Stops For Permit 20030251 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-05-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-26 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-26 |
Time |
07:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-04-16 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-04-16 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-04-16 |
Time |
11:58 |
Sent To |
|
|
Notes |
2020-04-16 12:20:41 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | THE STRUCTURAL ENCLOSURE AND SLAB PLANS ARE TO BE | | PROVIDED (SEPARATE PERMIT) AND COMPLETED BY THE GENERAL | | CONTRACTOR IN ACCORDANCE WITH THE MANUFACTURER'S | | SPECIFICATION INCLUDING THE GENERAC WIND LOAD | | COMPUTATIONS AND THE GENERAC ENGINEERING SUBMITTAL | | PACKAGE. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-21 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-03-21 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-21 |
Time |
15:22 |
Sent To |
|
|
Notes |
2020-03-21 15:30:20 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | 1) FBC B 107, PLEASE PROVIDE THE ENGINEER'S SIGNED AND | | SEALEDSTRUCTURAL DETAILS FOR THE ENCLOSURE INCLUDING | | THE SLAB. | | 2) FBC B 107, PLEASE PROVIDE THE ENGINEER'S SIGNED AND | | SEALED ANCHORING DETAILS FOR THE GENERATOR TO GENERATOR | | SLAB. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2020-05-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-05-20 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-05-20 |
Time |
08:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2020-05-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-05-13 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-05-13 |
Time |
09:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-04-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-04-27 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-04-27 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2020-04-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-04-22 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-04-22 |
Time |
11:36 |
Sent To |
|
|
Notes |
2020-04-22 12:13:29 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. CORRECTED. | | 2. PROVIDE LOAD CALCULATION FOR GENERATOR. NEC 220; WPB | | FBC 107.2.1 (NOT PROVIDED FROM 1ST REVIEW.) | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-03-23 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-03-23 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-03-23 |
Time |
10:34 |
Sent To |
FIRE |
|
Notes |
2020-03-23 10:34:20 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | THE DESIGN. A PRINTED SIGNATURE IS NOT ACCEPTABLE. A | | DIGITAL SIGNATURE ON A PAPER PLAN IS NOT ACCEPTABLE. | | PROVIDE CORRECTION. FS 471/481; WPB FBC 107.1, 107.2.1, | | 107.3.5.1.2 | | 2. PROVIDE LOAD CALCULATION FOR GENERATOR. NEC 220; WPB | | FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2020-05-21 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-05-21 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-05-21 |
Time |
13:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-04-16 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-04-16 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-04-14 |
Time |
13:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-03-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-03-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-03-23 |
Time |
12:04 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2020-05-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-26 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-14 |
Time |
10:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-05-13 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-05-04 |
Time |
11:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-04-27 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-04-24 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-04-22 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-04-13 |
Time |
11:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-03-23 |
|
|
Cont ID |
|
Sent By |
ccarvaja |
Date |
2020-03-23 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
ccarvaja |
Date |
2020-03-05 |
Time |
09:41 |
Sent To |
|
|
Notes |
2020-03-12 15:48:00 | 3/12 ROUTED TO GENERATOR INBOX | 2020-03-06 09:41:45 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2020-05-21 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-05-21 |
Time |
07:25 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-05-21 |
Time |
07:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-04-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-04-14 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-04-16 |
Time |
10:10 |
Sent To |
|
|
Notes |
2020-04-16 10:12:50 | STEPHNIE HALL FROM ELECTRASERVE EMAILED ME THE | | INFORMATION PETER VALENTI ASKED FOR. THE OTHER ISSUES I | | ASKED ABOUT ARE INCLUDED IN THE MASTER PERMIT. PROJECT | | IS APPROVED. | 2020-04-14 10:34:52 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT-20030251 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THIS IS A NEW INSTALLATION FOR A NEW BUILDING. | | PLEASE PROVIDE SPECS. FOR GENERATOR AND FUEL TANKS. | | SHOW ALSO HOW THIS GENERATOR WILL BE ANCHORED. PLEASE | | SHOW DETAILS OF GENERATOR SUPPORT SLAB. FBC FS 107.2.1 | | 2) PROVIDE COMPLETE MECHANICAL DRAWINGS SHOWING A CODE | | COMPLIANT INSTALLATION OF THIS GENERATOR INCLUDING | | COMPLETE DIAGRAM OF FUEL PIPING INSTALLATION. FBC M | | CHAPTER 13 FUEL OIL PIPING AND STORAGE. | | 3) ALSO NEEDED ON THESE CODE COMPLIANT PLANS SHOW THE | | GENERATOR LOCATION ALONG WITH LOT SETBACKS. SHOW THAT | | THE EXHAUST TERMINATION OF THIS GENERATOR WILL COMPLY | | WITH FBC M 501.3; FBC FS 107.2.1 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-03-23 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-03-23 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-03-21 |
Time |
15:30 |
Sent To |
|
|
Notes |
2020-03-23 08:42:04 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | MECHANICAL REVIEW DENIED: | | | | FBC B 107, PLEASE PROVIDE LOCATION OF FUEL TRUCK ACCESS | | AND REFUELING LINE ACCESS THROUGH ENCLOSURE. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2020-05-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-05-20 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-05-20 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2020-05-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-05-13 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-05-13 |
Time |
09:08 |
Sent To |
|
|
Notes |
2020-05-13 09:08:23 | ONLY ONE OF THE 3 ELECTRICAL SHEETS WAS CORRECTED. PER | | THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN IS | | REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY | | VERIFICATION. SELF-CERTIFICATION IS NOT ACCEPTABLE FOR | | ENGINEERS. PROVIDE CORRECTION. ALTERNATIVELY, A | | SIGNED/SEALED PAPER SET MAY BE SUPPLIED TO THE BUILDING | | DEPARTMENT WHEN ALL TRADES ARE APPROVED. WPB FBC 107.1; | | FS 471/481 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-04-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-04-27 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-04-27 |
Time |
13:53 |
Sent To |
|
|
Notes |
2020-04-27 13:53:28 | THIS ENGINEER WAS PREVIOUSLY WARNED THAT HIS DIGITAL | | SIGNATURE WAS NOT ACCEPTABLE. PER THE WPB AMENDMENTS TO | | THE FBC, EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED | | AND SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. A | | DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE WITH THE | | PROPER THIRD PARTY VERIFICATION. SELF-CERTIFICATION IS | | NOT ACCEPTABLE FOR ENGINEERS. PROVIDE CORRECTION. | | ALTERNATIVELY, A SIGNED/SEALED PAPER SET MAY BE | | SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL TRADES ARE | | APPROVED. WPB FBC 107.1; FS 471/481 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-04-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-04-22 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-04-22 |
Time |
12:21 |
Sent To |
|
|
Notes |
2020-04-22 12:21:39 | THIS ENGINEER WAS PREVIOUSLY WARNED THAT HIS DIGITAL | | SIGNATURE WAS NOT ACCEPTABLE. PER THE WPB AMENDMENTS TO | | THE FBC, EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED | | AND SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. A | | DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE WITH THE | | PROPER THIRD PARTY VERIFICATION. SELF-CERTIFICATION IS | | NOT ACCEPTABLE FOR ENGINEERS. PROVIDE CORRECTION. | | ALTERNATIVELY, A SIGNED/SEALED PAPER SET MAY BE | | SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL TRADES ARE | | APPROVED. WPB FBC 107.1; FS 471/481 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2020-04-24 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-04-24 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-04-24 |
Time |
|
Sent To |
|
|
Notes |
2020-04-24 13:08:33 | ZONING PASSED WITH THE FOLLOWING PROVISO: | | | | 1.) APPLICATION FOR A MINOR SITE PLAN AMENDMENT THROUGH | | THE DEVELOPMENT SERVICES DEPARTMENT - PLANNING | | DIVISION, IS REQUIRED PRIOR TO THE ISSUANCE OF A | | CERTIFICATE OF OCCUPANCY (C.O.). CONTACT LINDA LOUIE @ | | (561) 822-1458 IF THERE ARE QUESTIONS. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2020-04-15 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-04-15 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2020-04-15 |
Time |
|
Sent To |
|
|
Notes |
2020-04-15 08:27:55 | | | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) KEY SITE PLAN DOES NOT REFLECT THE LATEST CHANGES | | MADE TO THE LOCATION OF THE GENERATOR. PLEASE ADDRESS | | FOR CONSISTENCY. | | | | 2.) A MINOR SITE PLAN AMENDMENT FOR THE AS-BUILT | | REQUIRED PRIOR TO THE ISSUANCE OF A CERTIFICATE OF | | OCCUPANCY (C.O.). | | | | | | NOTES: | | | | * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * MASTER PERMIT: #18061140 (DR. ALICE MOORE APARTMENTS) | | | | * SCOPE: MODIFICATIONS TO LOCATION OF GENERATOR. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-03-12 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2020-03-12 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2020-03-12 |
Time |
|
Sent To |
|
|
Notes |
2020-03-12 15:04:43 | A MINOR SITE PLAN AMENDMENT WILL BE REQUIRED FOR THE | | AS-BUILT PRIOR TO THE ISSUANCE OF A CERTIFICATE OF | | OCCUPANCY (C.O.). |
|
|