Plan Review Stops For Permit 20030198 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-05-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-22 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-20 |
Time |
07:15 |
Sent To |
|
|
Notes |
2020-05-22 08:05:21 | 1. PROVISO: PROVIDE COMPACTION TEST REPORT TO CITY | | INSPECTOR. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-17 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-16 |
Time |
16:04 |
Sent To |
|
|
Notes |
2020-03-16 16:55:23 | SFR ALTERATION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE NEW EXTERIOR DOORS AND | | WINDOWS. | | 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE ROOFING SYSTEMS (SHINGLES AND | | LOW SLOPE ROOFING). | | 3) PLEASE SHOW THE STAIR HANDRAIL REQUIREMENTS AND | | DETAILS TO COMPLY WITH FBC R311.7.8 | | 4) PLEASE SHOW THE WINDOW SIZES (WIDTH AND HEIGHT). | | SHOW THAT THE BEDROOM WINDOWS MEET EMERGENCY EGRESS | | REQUIREMENTS PER FBC R310.1 | | 5) PLEASE SHOW THE 2ND FLOOR EXTERIOR DECK (ROOFING) | | SLOPE TO COMPLY WITH FBC R905.11.1 | | 6) PLEASE SHOW THE 2ND FLOOR EXTERIOR DECK (ROOF) DRAIN | | TO COMPLY WITH FBC R903.4 AND THE OVERFLOW DRAINAGE TO | | COMPLY WITH FBC R903.4.1 | | 7) PLEASE SHOW THE NAILING AND LAPPING REQUIREMENTS FOR | | THE 2X'S JOINED TOGETHER TO CREATE BEAMS (30' LONG | | DOUBLE JOIST) AND POST (4 AND 5 2X'S) | | 8) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT OR | | PROVIDE A NOTE ON THE DRAWING FOR THE BEARING CAPACITY | | OF THE SOIL. FBC R401.4 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-22 |
Time |
07:54 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-20 |
Time |
07:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2020-03-26 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-03-26 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-03-26 |
Time |
13:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-22 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-22 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-06-03 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-05-15 |
Time |
10:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-03-26 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2020-03-26 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2020-03-04 |
Time |
13:03 |
Sent To |
|
|
Notes |
2020-03-23 14:38:34 | R12 | 2020-03-05 13:03:31 | R12 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2020-06-12 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-06-12 |
Time |
08:14 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-06-03 |
Time |
09:00 |
Sent To |
|
|
Notes |
2020-06-11 16:49:05 | MU 2020-18921 - $1069.69 - PAID | 2020-06-03 09:00:26 | 6/3/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-17 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-17 |
Time |
08:58 |
Sent To |
|
|
Notes |
2020-03-17 08:59:40 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-22 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-20 |
Time |
07:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2020-03-13 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-03-13 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-03-13 |
Time |
07:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-22 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-20 |
Time |
07:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-03-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-03-25 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-03-25 |
Time |
13:53 |
Sent To |
|
|
Notes |
2020-03-25 16:21:03 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT #20030198 | | 3/25/20 | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET 12: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW | | WATER HEATER AND SUBMIT MANUFACTURER'S SPECIFICATIONS. | | | | 2) SHEET 12: REFER TO SECTIONS P2801.6, P2801.6.1, | | P27801.6.2 FBC RES: A PAN AND A PAN DRAIN ARE REQUIRED | | FOR THE WATER HEATER. THE PAN DRAIN SHALL BE A 3/4" | | PIPE WHICH SHALL EXTEND FULL SIZE AND TERMINATE OVER A | | SUITABLE LOCATED WASTE RECEPTOR, OR SHALL EXTEND TO THE | | EXTERIOR OF THE BUILDING AND TERMINATE NOT LESS THAN 6 | | INCHES AND NOT MORE THAN 24 INCHES ABOVE THE GROUND | | SURFACE. PLEASE SEE TABLE 2906.5 FOR ALLOWABLE PIPE | | MATERIAL. PLEASE CORRECT THE PLAN TO SHOW COMPLIANCE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-05-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-05-22 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-05-20 |
Time |
07:15 |
Sent To |
|
|
Notes |
2020-05-22 07:54:03 | NO NOTES |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-03-17 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-03-17 |
Time |
08:59 |
Sent To |
|
|
Notes |
2020-03-17 09:01:05 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-05-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-05-19 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-05-19 |
Time |
11:58 |
Sent To |
|
|
Notes |
2020-05-19 11:59:24 | PASSED PER FBPE EMERGENCY ORDER (COVID-19) | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-06-03 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-06-03 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2020-06-03 |
Time |
|
Sent To |
|
|
Notes |
2020-06-03 11:07:03 | ************ZONING PROVISO********* | | | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, | | THE FOLLOWING CONDITIONS SHALL BE ADDRESSED: | | | | 1. A LANDSCAPE PERMIT, WHICH INCLUDES A LANDSCAPE PLAN, | | SHALL BE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW. | | | | 2. THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED | | LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL | | LANDSCAPE INSPECTION. | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2020-03-23 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-03-23 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2020-03-23 |
Time |
|
Sent To |
|
|
Notes |
2020-03-23 10:57:50 | ******************************ZONING REVIEW | | FAILED****************** | | | | PLEASE INDICATE THE SETBACKS FOR THE NEW PORCH ON THE | | SURVEY. | | | | PROJECT VALUE TRIGGERS THE LANDSCAPE CODE. | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | PERMIT. SHOWING THE FOLLOWING: | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | BEACH | | SECTION 94-442(C)(2)A. | | | | GROSS LOT SQUARE FOOTAGE MINUS | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | PORTION THEREOF | | | | | | ALANA WOOTEN | | PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|