2020-03-16 09:49:35 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 20021167 |
| ADD: 10435 TERRA LAGO DR. |
| CONT: ROY SMITH SCREENS AND SHUTTERS, INC. |
| TEL: 561-422-5000 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION. |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: MONDAY, MARCH 16TH/ 2020 |
| ACTION: DENIED |
| |
| 1) THE SITE PLAN SUBMITTED SHOWS A POOL (PERMIT: |
| 04071264) BUT THE SITE PLAN DOES NOT INDICATE THE |
| DISTANCE BETWEEN THE POOL/ SPA AND THE PROPOSED SCREEN |
| ENCLOSURE WALL LINE. THE PROPOSED POOL PLAN SHOWS A |
| DISTANCE OF 8 FEET- 4 INCHES FROM THE WATERLINE TO THE |
| PROPOSED SCREEN ENCLOSURE WALL LINE. |
| 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. THERE IS |
| GOING TO BE A NEW FOUNDATION WHICH SHOULD HAVE STEEL IN |
| THE FOOTER PLUS THE VERTICAL ALUMINUM EXTRUSIONS WILL |
| BE WITHIN 10 FEET OF THE WATER LINE. COMPLIANCE WITH |
| THE 2017 FBC-R 4501.16 BONDING AND GROUNDING OF METAL |
| COMPONENTS WITHIN 10 FEET OF THE WATER LINE TO |
| ELECTRICAL BONDING OF POOL COMPONENTS. |
| |
| 2) THE PERMIT APPLICATION UNDER THE HEADING OF PROPOSED |
| WORK INDICATES 12 X 12 INCH STRIP FOOTERS. THERE IS NO |
| FLOOR PLAN, NOR FOUNDATION PLAN AS TO THE TYPE OF |
| MATERIAL THE FOUNDATION IS TO CONSIST OF NOR AT WHAT |
| DEPTH THIS FOOTER IS TO OCCUR, NOR IS THE QUANTITY, NOR |
| SIZE OF STEEL RE-BAR REINFORCING TO OCCUR IN THE |
| FOUNDATION. |
| 107.3.5.3 RESIDENTIAL BUILDINGS: |
| FLOOR PLAN MISSING |
| FOUNDATION PLAN MISSING |
| STRUCTURAL PLAN WITH THE SIZE AND SPACING OF THE |
| VERTICAL ALUMINUM FRAMING MEMBERS FOR THE WIND SPEED |
| INDICATED (160 VULT / 124 VASD) AND ANCHORAGE OF THESE |
| FRAMING MEMBERS. NOTE THE PERMIT APPLICATION INDICATES |
| PAVERS ON TOP OF THE FOUNDATION, HOW THICK ARE THE |
| PAVERS TO BE AND LONG ARE THE ANCHORS TO REACH THE |
| FOUNDATION, HOW DEEP MUST THE ANCHORS GO INTO THE |
| FOUNDATION? 107. 2.1.2 ADDITIONAL INFORMATION IS |
| REQUIRED. 2017 FBC-B SECTION 2002.4 SCREEN ENCLOSURES/ |
| LOADS. |
| |
| 3) DOES THE NEW MOTORIZED ROLL UP SCREEN ENCLOSURE |
| AFFECT THE POOL BARRIER TO TTHE DWELLING, SHOW |
| COMPLIANCE WITH 454.2.17.1.9. |
| |
| 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE |
| THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED |
| DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE |
| MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS |
| AND INFORMATION LACKING UNDER THE PRIOR REVIEW. |
| |
| |