Plan Review Details - Permit 20021052
Plan Review Stops For Permit 20021052
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-03-19 Cont ID  
Sent By rmcphers Date 2020-03-19 Time 14:25 Rev Time 0.00
Received By rmcphers Date 2020-03-19 Time 14:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-03-17 Cont ID  
Sent By rmcphers Date 2020-03-17 Time 13:25 Rev Time 0.00
Received By rmcphers Date 2020-03-17 Time 13:25 Sent To  
Notes
2020-03-17 13:25:02POOL BARRIER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) POOL BARRIERS NEED TO COMPLY WITH FBC R4501.17.1
 2) PLEASE SHOW CLEARLY WHERE THE FENCE IS ABUTTING THE
 HOUSE FOR THE BARRIER LOCATION. IF THE FENCE IS
 SURROUNDING THE ENTIRE PROPERTY ACTING AS THE POOL
 BARRIER - THEN THE DRIVEWAY ROLL GATE WILL NEED TO
 COMPLY WITH FBC R4501.17.1.8
 3) PLEASE SHOW ROLL GATE TO COMPLY WITH FBC R4501.17.1
 - THE MAXIMUM VERTICAL CLEARANCE BETWEEN GRADE AND THE
 BOTTOM OF THE BARRIER SHALL BE 2 INCHES (51 MM)
 MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY
 FROM THE SWIMMING POOL. (YOU SHOW 3 INCHES)
 R4501.17.1.2
 THE BARRIER MAY NOT HAVE ANY GAPS, OPENINGS,
 INDENTATIONS, PROTRUSIONS, OR STRUCTURAL COMPONENTS
 THAT COULD ALLOW A YOUNG CHILD TO CRAWL UNDER, SQUEEZE
 THROUGH, OR CLIMB OVER THE BARRIER AS HEREIN DESCRIBED
 BELOW. OPENINGS IN ANY BARRIER SHALL NOT ALLOW PASSAGE
 OF A 4-INCH-DIAMETER (102 MM) SPHERE.
 R4501.17.1.4
 WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND
 VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF
 THE HORIZONTAL MEMBERS IS LESS THAN 45 INCHES (1143
 MM), THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE
 SWIMMING POOL SIDE OF THE FENCE. SPACING BETWEEN
 VERTICAL MEMBERS SHALL NOT EXCEED 1 3/4 INCHES (44 MM)
 IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS WITHIN
 VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT
 EXCEED 1 3/4 INCHES (44 MM) IN WIDTH.
 R4501.17.1.7
 WHERE THE BARRIER IS COMPOSED OF DIAGONAL MEMBERS, THE
 MAXIMUM OPENING FORMED BY THE DIAGONAL MEMBERS SHALL BE
 NO MORE THAN 1 3/4 INCHES (44 MM).
 R4501.17.1.8
 ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND
 SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS
 R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED
 WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL
 SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED
 NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE
 GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON
 EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE
 REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY
 OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE
 ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM
 THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING
 GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457
 MM) OF THE RELEASE MECHANISM.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-04 Cont ID  
Sent By rmcphers Date 2020-03-03 Time 14:24 Rev Time 0.00
Received By rmcphers Date 2020-03-03 Time 14:24 Sent To  
Notes
2020-03-04 13:25:44POOL BARRIER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) POOL BARRIERS NEED TO COMPLY WITH FBC R4501.17.1
 2) PLEASE PROVIDE A SITE PLAN SHOWING THE LOCATION OF
 THE POOL.
 3) PLEASE SHOW CLEARLY WHERE THE FENCE IS ABUTTING THE
 HOUSE FOR THE BARRIER LOCATION. IF THE FENCE IS
 SURROUNDING THE ENTIRE PROPERTY ACTING AS THE POOL
 BARRIER - THEN THE DRIVEWAY ROLL GATE WILL NEED TO
 COMPLY WITH FBC R4501.17.1.8
2020-03-03 14:26:38POOL BARRIER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) POOL BARRIERS NEED TO COMPLY WITH FBC R4501.17.1
 2) PLEASE PROVIDE A SITE PLAN SHOWING THE LOCATION OF
 THE POOL.
 3) PLEASE SHOW CLEARLY WHERE THE FENCE IS ABUTTING THE
 HOUSE FOR THE BARRIER LOCATION. IF THE FENCE IS
 SURROUNDING THE ENTIRE PROPERTY ACTING AS THE POOL
 BARRIER - THEN THE DRIVEWAY ROLL GATE WILL NEED TO
 COMPLY WITH FBC R4501.17.1.8

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-19 Cont ID  
Sent By rmcphers Date 2020-03-19 Time 14:26 Rev Time 0.00
Received By rmcphers Date   Time   Sent To  
Notes
2020-03-19 14:26:56TAKEN IN AT MEET AND GREET

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-17 Cont ID  
Sent By rmcphers Date 2020-03-17 Time 13:26 Rev Time 0.00
Received By rmcphers Date 2020-03-10 Time 13:20 Sent To  
Notes
2020-03-17 13:26:44PLANS TAKEN TO PERMIT LIBRARY
2020-03-16 16:44:063/16 RESUB ROUTED TO RMCPHERSON
2020-03-11 13:20:11RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-03-03 Cont ID  
Sent By rfalcone Date 2020-03-03 Time 14:24 Rev Time 0.00
Received By rmcphers Date 2020-02-25 Time 13:12 Sent To  
Notes
2020-03-03 14:25:47PLANS TAKEN TO PERMIT LIBRARY
2020-02-27 16:48:362/27 ROUTED TO BLDG MISC 2
2020-02-26 13:12:45ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2020-03-16 Cont ID  
Sent By rfalcone Date 2020-03-16 Time 14:27 Rev Time 0.00
Received By rfalcone Date 2020-03-16 Time 14:27 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-02-27 Cont ID  
Sent By rfalcone Date 2020-02-27 Time 16:27 Rev Time 0.00
Received By rfalcone Date 2020-02-27 Time 16:27 Sent To I
Notes
2020-02-27 16:34:192/27/2020 FAILED.
  
 PLEASE PROVIDE A VISABILITY TRIANGLE ON THE SITE.
  
 PURSUANT ZLDR SEC. 94-305(E)VISIBILITY AT
 INTERSECTIONS. AT ANY ROAD INTERSECTIONS, VISIBILITY
 SHALL NOT BE OBSCURED BY THE CONSTRUCTION, PLACEMENT,
 OR MAINTENANCE OF A STRUCTURE WALL, SIGN, FENCE, BERM,
 PLANT MATERIAL, SHRUBS, OR ANY SIMILAR ITEM BETWEEN 18
 INCHES OR EIGHT FEET IN HEIGHT WITHIN A TRIANGLE
 BEGINNING AT THE POINT WHERE PROPERTY LINES MEET AT THE
 CORNER, THEN 20 FEET ALONG THE FRONT PROPERTY LINE,
 THENCE DIAGONALLY TO A POINT ALONG THE SIDE PROPERTY
 LINE 20 FEET FROM THE POINT OF BEGINNING, AND THENCE TO
 THE POINT OF BEGINNING. IN THE EVENT THE CORNER OF AN
 INTERSECTION IS ROUNDED, THE MEASUREMENT SHALL BEGIN AT
 THE POINT THE PROPERTY LINES WOULD MEET WITHOUT
 ROUNDING. (SEE FIGURE X-1)
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 RACHEL FALCONE, ASSOCIATE PLANNER
 DEVELOPMENT SERVICES DEPARTMENT
 E-MAIL: [email protected]
 TEL: (561) 822-1442