Plan Review Stops For Permit 20021000 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2020-05-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-05-07 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-05-07 |
Time |
11:02 |
Sent To |
|
|
Notes |
2020-05-07 11:11:14 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW APPROVED: | | | | THE ENGINEER HAS CLARIFIED AND AND UPDATED THE REQUIRED | | CORRECTIONS. | | THE SIGNED AND SEALED CORRECTIONS (PAGE A-1 AND | | CLARIFICATION LETTER) HAVE BEEN SUBMITTED ON PAPER TO | | THE DROP BOX. | | THEY HAVE NOW BEEN REVIEWED, APPROVED, AND ARE NOW IN | | PROCESS OF BEING SCANNED INTO PROJECT DOX. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2020-05-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-05 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-05 |
Time |
15:02 |
Sent To |
|
|
Notes |
2020-05-05 15:10:00 | SFR REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) DRAWING A-1 HAS A DETAIL FOR A LEDGER BOARD DETAIL | | SHOWING 3/8" TAPCONS INTO A STEEL TUBE BEAM - TAPCONS | | ARE NOT AN ACCEPTABLE ANCHOR FOR ATTACHMENT TO A STEEL | | BEAM, PLEASE REVISE DETAIL. PLEASE SHOW THE TYPE LENGTH | | AND DIAMETER OF THE ANCHOR TO BE USED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-04-24 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-04-24 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-04-24 |
Time |
08:31 |
Sent To |
|
|
Notes |
2020-04-24 09:27:02 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | 2ND BUILDING REVIEW DENIED: | | | | CORRECTIONS NEEDED ? FBC WPB AMENDMENTS 107 | | | | 1) FAILED: THE NEW DRAWING A?1 HAS A DETAIL FOR A | | LEDGER BOARD DETAIL | | SHOWING 3/8" TAPCONS AT 12" O.C. INTO A STEEL BEAM ? | | TAPCONS ARE NOT AN ACCEPTABLE ANCHOR FOR ATTACHMENT TO | | A STEEL | | BEAM, PLEASE REVISE DETAIL. PLEASE SHOW THE TYPE LENGTH | | AND DIAMETER OF THE ANCHOR TO BE USED. | | | | 2) OK | | | | 3) OK (PER PRODUCT APPROVA) | | | | 4) FAILED: PLEASE SHOW THE DETAILS FE EXTERIOR WALL | | INFILL. | | | | | | 5) OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-02-28 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-02-28 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-02-28 |
Time |
14:22 |
Sent To |
|
|
Notes |
2020-02-28 15:28:17 | SFR REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) DRAWING A-1 HAS A DETAIL FOR A LEDGER BOARD DETAIL | | SHOWING 5/8" LAG BOLTS INTO A STEEL BEAM - LAG BOLTS | | ARE NOT AN ACCEPTABLE ANCHOR FOR ATTACHMENT TO A STEEL | | BEAM, PLEASE REVISE DETAIL. PLEASE SHOW THE TYPE LENGTH | | AND DIAMETER OF THE ANCHOR TO BE USED. | | 2) PLEASE SHOW THE WIND DESIGN CRITERIA USED - FBC | | R301.2.1.1 - - - FBC 1603.1.4 | | 3) PLEASE SHOW THE EXTERIOR DOOR OPENING WIND DESIGN | | PRESSURE FBC R301.2.1 | | 4) PLEASE SHOW THE DETAILS FOR THE EXTERIOR WALL | | INFILL. | | 5) PLEASE PROVIDE COMPLETE (FRONT PAGES AND | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE NEW EXTERIOR DOOR. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-04-29 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-04-29 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-04-29 |
Time |
14:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-03-16 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-03-16 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-03-16 |
Time |
14:44 |
Sent To |
|
|
Notes |
2020-03-16 14:58:14 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. SOME AREAS ARE MISSING THE REQUIRED SMOKE | | ALARM. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | 2. PLAN DOES NOT SHOW THE DEDICATED CIRCUIT FOR | | BATHROOM RECEPTACLE OUTLET. A MINIMUM OF ONE 20 AMPERE | | BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM | | RECEPTACLE OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER | | OUTLETS. PROVIDE CORRECTION. NEC 210.11(C)(3) , FBC RE | | E3703.4 | | 3. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | 210.8(D); FBC RE E3902.10 | | 4. RECEPTACLES INSTALLED TO SERVE THE COUNTER TOP IN | | KITCHEN, INCLUDING THE ISLAND, REQUIRE GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.6 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-05-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-05 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-04 |
Time |
15:05 |
Sent To |
|
|
Notes |
2020-05-04 15:06:13 | ROUTED TO PETER'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-04-29 |
Time |
|
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-04-22 |
Time |
14:47 |
Sent To |
|
|
Notes |
2020-04-23 14:59:47 | SENT TO R1 BIN. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2020-03-17 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-02-24 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2020-04-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-04-27 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-04-27 |
Time |
13:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-03-17 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-03-17 |
Time |
16:09 |
Sent To |
I |
|
Notes |
2020-03-17 16:18:37 | 1ST REVIEW FBC-2017 PLUMBING | | PERMIT #20021000 | | 3/17/20 | | | | CODES IN EFFECT: | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET E-1: ADD THE RELOCATED BATHTUB TO THE SANITARY | | RISER- SECTIONS P3005.4 AND P3101.2.1 FBC RES | | | | 2) E-1: PROVIDE A SANITARY RISER DRAWING FOR THE | | REMODELED KITCHEN- SINK AND DISHWASHER DRAINS AND | | VENTING- SECTIONS P3005.4 AND P3101.2.1 FBC RES | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | CHRISTOPHER L. COLE | | PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-05-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-05-07 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-05-07 |
Time |
11:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-04-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-04-29 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-04-29 |
Time |
11:28 |
Sent To |
|
|
Notes |
2020-04-29 11:28:31 | ORIGNAL S&S PLANS PROVIDED | | |
|
|