Plan Review Stops For Permit 20020745 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2020-03-05 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2020-03-05 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2020-03-05 |
Time |
14:21 |
Sent To |
|
|
Notes |
2020-03-05 14:22:33 | ADDRESS SHOULD BE 347 SUMMA ST, CHANGED ADDRESS IN | | COMMUNITY PLUS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2020-05-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-14 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-14 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-04-13 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-04-13 |
Time |
11:18 |
Sent To |
|
|
Notes |
2020-04-13 16:41:07 | NEW BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) SURVEY NEEDS TO BE ELECTRONICALLY SIGNED BY THE | | SURVEYOR. (DOES NOT SHOW IN "ADOBE" AS ELECTRONICALLY | | SIGNED. | | 2) PLEASE SHOW THE FLOOD ZONE PER THE LATEST FIRM. | | 3) ELECTRONIC SIGNATURE ON THE STRUCTURAL DRAWINGS | | NEEDS TO BE VERIFIED BY A CERTIFICATION AUTHORITY - SEE | | 61G15-23.004(2). | | 4) PLEASE PROVIDE A SIGNED AND SEALED SOIL REPORT. | | 5) PLEASE SHOW THE REQUIRED HANDRAILING AT THE STAIRS ( | | HEIGHT, EXTENSIONS AND ONE ON EACH SIDE) TO COMPLY WITH | | FBC 1014. | | 6) PLEASE SHOW TERMITE TREATMENT REQUIRED TO COMPLY | | WITH FBC 1816. | | 7) PLEASE PROVIDE SIDING ATTACHMENT DETAILS OR PRODUCT | | APPROVALS. | | 8) PLEASE PROVIDE SOLAR PANEL ATTACHMENT DETAILS OR | | PRODUCT APPROVALS. | | 9) PLEASE SHOW THE REQUIRED NAILING FOR THE STRAPPING | | (SIZE OF NAIL OR SCREW AND AMOUNT). | | 10) PLEASE PROVIDE THE PRODUCT APPROVAL FOR THE METAL | | ROOFING. | | 11) ANY DEFERRALS PLEASE PUT IN WRITING. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2020-03-13 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2020-03-13 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2020-03-11 |
Time |
09:21 |
Sent To |
|
|
Notes |
2020-03-13 17:01:40 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 20020745 | | REVIEWED: MARCH 13, 2020 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC[B] = FBC BUILDING | | FBC[A] = FBC ACCESSIBILITY | | FBC[E] = FBC ENERGY CONSERVATION | | | | 1) 1004 FBC[B]SHEET G-101 (MAIN BUILDING) | | PLEASE BASE OCCUPANCY UPON THE INTENDED USE. 15 SQ. FT. | | PER OCCUPANT IS FOR TABLES AND CHAIRS. THE PLAN IS | | SHOWN WITH CHAIRS ONLY AND THERE ARE 85 CHAIRS | | REPRESENTED. CONCENTATED CHAIRS USES 7 SQ. FT. PER | | OCCUPANT. SINCE THIS SPACE WILL BE USED FOR A VARIETY | | OF ASSEMBLY AND YOU ARE DEVIATING FROM CODE WORST CASE, | | PLEASE CONTACT THE FIRE MARSHALL AND BUILDING OFFICIAL | | TO DISCUSS. | | [email protected] (FIRE MARSHALL) AND [email protected] | | (BUILDING OFFICIAL) | | SHOW CLEAR PATH OF EGRESS OR SHOW DIMENSION BETWEEN | | CHAIRS AND WALL SINCE IT APPEARS LESS THAN 36 INCHES. | | | | 2) 1004 FBC[B]ADJUST THE TAG MAIN INTERIO ASSEMBLY. IT | | SHOWS B AND USES 15 FOR COME UP WITH 59 OCCUPANTS. | | PLEASE UPDATE TO A-3 AND USE OCCUPANT FACTOR BASED ON | | USE OF THE SPACE. | | | | 3) 1004 FBC[B] SHEET G-10 (RESTROOM FACILITY) | | LOCKER ROOMS ARE USING BUSINESS OCCUPANCY AT 100 SQ. | | FT. PER, BUT THERE IS A 50 GROSS FOR LOCKER ROOMS | | STATED IN TABLE 1004.1.2 | | ALSO, BUSINESS IS USED FOR MAIN RESTROOM AREA. THESE | | DON?T SUPPORT BUSINESS USES. PLEASE USE OCCUPANCY COUNT | | AT LEAST MINIMUM OF FIXTURES SINCE THEY COULD BE USED | | SIMULTANEOUSLY. | | | | 4) 401.2 FBC[CE] APPLICATION. COMMERCIAL BUILDINGS | | SHALL COMPLY WITH ONE OF THE FOLLOWING: | | 1. THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1, | | EXCLUDING SECTION 9.4.1.1(G) OF THE STANDARD. | | 2. THE REQUIREMENTS OF SECTIONS C402 THROUGH C405. IN | | ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY WITH | | SECTION C406 AND TENANT SPACES SHALL COMPLY WITH | | SECTION C406.1.1. | | 3. THE REQUIREMENTS OF SECTIONS C402.5, C403.2, C404, | | C405.2, C405.3, C405.5, C405.6 AND C407. THE BUILDING | | ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 PERCENT | | OF THE STANDARD REFERENCE DESIGN BUILDING. | | - PLEASE PROVIDE DOCUMENTATION FOR COMPLIANCE WITH THE | | ENERGY CODE FOR EACH BUILDING. | | | | 5) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR | | WINDOWS, WINDOW MULL AND TRANSOM, OR INDICATE THAT THIS | | WILL BE A DEFERRED SUBMITTAL. | | | | 6) 107.2.1.2 FBC[AMENDED] PROVIDE STAIRCASE AND GUARD | | RAIL ENGINEERING, OR INDICATE THAT IT WILL BE DEFERRED | | SUBMITTAL. | | | | 7) 1507.4.2 FBC[B] DECK SLOPE. MINIMUM SLOPES FOR METAL | | ROOF PANELS SHALL COMPLY WITH THE FOLLOWING: | | A. THE MINIMUM SLOPE FOR LAPPED, NONSOLDERED SEAM METAL | | ROOF PANELS WITHOUT APPLIED LAP SEALANT SHALL BE THREE | | UNITS VERTICAL IN 12 UNITS HORIZONTAL (25-PERCENT | | SLOPE). | | B. THE MINIMUM SLOPE FOR LAPPED, NONSOLDERED SEAM METAL | | ROOF PANELS WITH APPLIED LAP SEALANT SHALL BE ONE-HALF | | UNIT VERTICAL IN 12 UNITS HORIZONTAL (4-PERCENT SLOPE). | | LAP SEALANTS SHALL BE APPLIED IN ACCORDANCE WITH THE | | APPROVED MANUFACTURER?S INSTALLATION INSTRUCTIONS. | | B. THE MINIMUM SLOPE FOR STANDING-SEAM METAL ROOF PANEL | | SYSTEMS SHALL BE ONE-QUARTER UNIT VERTICAL IN 12 UNITS | | HORIZONTAL (2-PERCENT SLOPE). | | -PLEASE PROVIDE PRODUCT APPROVALS FOE METAL ROOFING | | THAT MEET 1507.4.2, OR INDICATE THAT THIS WILL BE A | | DEFERRED SUBMITTAL. | | | | 8) 107.3.4.1 FBC[AMENDED] SUBMIT TRUSS SHOP DRAWINGS TO | | THE BUILDING INSPECTOR PRIOR TO INSTALLATION. | | - THE TRUSS SUBMITTAL CAN BE APPROVED NOW IF PUT IN | | SUPPORTING DOCUMENTS AS A SUBMITTAL, OR IT CAN BE | | DEFERRED. IF DEFERED THE TRUSS PACKAGE NEEDS TO BE | | REVIEWED BY BUILDING INSPECTOR PRIOR TO INSTALLATION. | | | | 9) 803.4 FBC[A] BENCHES. A BENCH COMPLYING WITH 903 | | SHALL BE PROVIDED WITHIN THE ROOM. | | | | 10) 903.4 FBC[A] BACK SUPPORT. THE BENCH SHALL PROVIDE | | FOR BACK SUPPORT OR SHALL BE AFFIXED TO A WALL. BACK | | SUPPORT SHALL BE 42 INCHES LONG MINIMUM AND SHALL | | EXTEND FROM A POINT 2 INCHES MAXIMUM ABOVE THE SEAT | | SURFACE TO A POINT 18 INCHES MINIMUM ABOVE THE SEAT | | SURFACE. BACK SUPPORT SHALL BE 21/2 INCHES MAXIMUM FROM | | THE REAR EDGE OF THE SEAT MEASURED HORIZONTALLY. | | | | NOTES: | | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | | | FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F 8-5) TO | | DISCUSS COMMENTS, OR E-MAIL ANYTIME [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-05-15 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-05-15 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-05-15 |
Time |
14:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2020-04-10 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-04-10 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-04-10 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2020-03-17 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-03-17 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-03-11 |
Time |
10:34 |
Sent To |
|
|
Notes |
2020-03-17 12:59:37 | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) NEED TO SUBMIT AN AIC CALCULATION FOR THE SERVICE | | 110.24 | | | | 2) OUTLET(S) FOR WATER FOUNTAIN TO BE ACCESSIBLE IF | | THEY ARE OF THE GCFI TYPE. 422.52, 422.5 | | | | 3) NEED A LOAD CALCULATION PER 220, 215.5 | | | | 4) LOW VOLTAGE, SITE LIGHTING, FIRE ALARM, AND SOLAR | | SYSTEMS ALL REQUIRE SEPARATE PERMITS. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2020-05-13 |
|
|
Cont ID |
|
Sent By |
Mgonzale |
Date |
2020-05-13 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2020-05-13 |
Time |
|
Sent To |
I |
|
Notes |
2020-05-13 12:22:57 | REVIEWED UNDER ENGINEERING PROJECT. | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2020-04-20 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-04-20 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2020-04-20 |
Time |
|
Sent To |
I |
|
Notes |
2020-04-20 14:19:24 | FORMAL ENGINEERING SUBMITTAL CURRENTLY UNDER REVIEW. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2020-03-16 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2020-03-16 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2020-03-16 |
Time |
|
Sent To |
|
|
Notes |
2020-03-16 14:33:50 | PLEASE SUBMIT FOR SITE PLAN AND FORMAL ENGINEERING | | REVIEW. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2020-05-11 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-05-08 |
Time |
10:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-04-10 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-04-10 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-04-10 |
Time |
09:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2020-03-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-03-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-03-06 |
Time |
11:44 |
Sent To |
|
|
Notes |
2020-03-06 11:57:07 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) SHEET G 101 - THE OCCUPANCY LOAD CALCULATION FOR THE | | CONFERENECE ROOM IS INDICATED AS B 100/3. THIS | | CONFERENCE ROOM IS AN ASSEMBLY SPACE PER THE FL FIRE | | PREVENTION CODE. | | | | THE OCCUPANCY LOAD SHOULD BE 20, WITH AN A REPLACE THE | | B DESIGNATION. | | | | PLEASE REVIEW AND REVISE AT THE APPLICABLE TIME PRIOR | | TO CO | | | | | | | | 2) SHEET G 101 - THE OCCUPANCY LOAD CALCULATION FOR THE | | LARGE OPEN CONFERENECE SPACE IS INDICATED A B WHERE IT | | SHOULD BE A. | | | | PLEASE REVIEW AND REVISE AT THE APPLICABLE TIME PRIOR | | TO CO | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2020-06-04 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-06-04 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-05-27 |
Time |
10:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-05-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-05-15 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-05-07 |
Time |
10:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2020-04-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-04-22 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-04-09 |
Time |
09:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2020-03-17 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-03-17 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-02-26 |
Time |
11:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2020-05-27 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2020-05-27 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2020-05-15 |
Time |
08:20 |
Sent To |
|
|
Notes |
2020-05-27 11:31:38 | NO FEES DUE PER IMPACT FEE OFFICE. LEM | 2020-05-15 08:20:48 | 5/15/20 EMAILED IMPACT FEE OFFICE. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2020-03-11 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2020-03-11 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2020-03-11 |
Time |
13:15 |
Sent To |
|
|
Notes |
2020-03-11 13:16:02 | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2020-06-02 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2020-06-01 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2020-06-01 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2020-05-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2020-05-15 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2020-05-15 |
Time |
13:57 |
Sent To |
|
|
Notes |
2020-05-15 14:40:44 | PLAN DENIED | | REFER TO SECTION C403.2.1 FLORIDA ENERGY CODE 2017 | | CALCULATION OF HEATING AND COOLING LOADS REQUIRED. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2020-05-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-05-08 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-05-08 |
Time |
08:02 |
Sent To |
|
|
Notes |
2020-05-08 14:56:01 | 3RD REVIEW FBC-2017 MECHANICAL | | PERMIT #20020745 | | 5/8/20 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) I WAS NOT ABLE TO LOCATE THE PREVIOUSLY SUBMITTED AC | | CALCULATIONS. PLEASE RE-SUBMIT THE CALCULATIONS OR | | PROVIDE NEW CALCULATIONS FOR THE SYSTEMS- SECTION | | C403.2.1 FBC EC. | | | | PLEASE UPDATE AND UPLOAD CORRECTED PLAN SHEETS TO | | ADDRESS THE COMMENTS FROM THE 1ST REVIEW LISTED BELOW. | | | | 1) SHEET M-101: AIR HANDLERS ARE NOT ALLOWED IN THE | | ATTICS OF COMMERCIAL BUILDINGS- SECTION C403.2.9.6 FBC | | EC. THE UNITS WILL HAVE TO BE RELOCATED. | | SHEET M101: THE ARCHITECT'S RESPONSE THAT THE SPACE | | ABOVE THE CEILING IS NOT AN ATTIC BY DEFINITION IS | | ACCEPTED, HOWEVER THE ENGINEER OF RECORD HAS NOT | | REMOVED OR CORRECTED KEY NOTES #8, 9, 11, & 12 WHICH | | IDENTIFY THE SPACE AS AN ATTIC. | | | | 6) PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL | | ROOMS AND SPACES PER TABLE 403.3.1.1 FBC ML. PROVIDE A | | SCHEDULE ON THE PLAN THAT INDICATES THE REQUIRED AND | | PROVIDED CFMS OF OUTDOOR AIR. | | THE VENTILATION CALCULATIONS ON SHEET M-101 CAN NOT BE | | CHECKED FOR COMPLIANCE WITH TABLE 403.3.1.1 FBC M | | BECAUSE THEY DO NOT INDICATE THE REQUIRED CFMS PER | | PERSON AND CFMS PER SQ. FT. OF THE ROOMS OR SPACES. | | PLEASE PROVIDE A COMPLETE CALCULATION TABLE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2020-04-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-04-10 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-04-10 |
Time |
14:02 |
Sent To |
|
|
Notes |
2020-04-10 16:48:30 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT #20020745 | | 4/10/20 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | COMMENTS FROM THE 1ST REVIEW LISTED BELOW STILL EXIST | | EITHER PARTIALLY OR ENTIRELY. | | | | 1) SHEET M-101: AIR HANDLERS ARE NOT ALLOWED IN THE | | ATTICS OF COMMERCIAL BUILDINGS- SECTION C403.2.9.6 FBC | | EC. THE UNITS WILL HAVE TO BE RELOCATED. | | SHEET M101: THE ARCHITECT'S RESPONSE THAT THE SPACE | | ABOVE THE CEILING IS NOT AN ATTIC BY DEFINITION IS | | ACCEPTED, HOWEVER THE ENGINEER OF RECORD HAS NOT | | REMOVED OR CORRECTED KEY NOTES #8, 9, 11, & 12 WHICH | | IDENTIFY THE SPACE AS AN ATTIC. | | | | 3) M-101: PROVIDE A DUCT SMOKE DETECTOR IN THE SUPPLY | | SYSTEM OF AHU-2 PER SECTION 606.2.1 FBC M. PLEASE NOTE | | THAT AN EXEMPTION CAN BE APPLIED IF THE MANUFACTURER'S | | PERFORMANCE DATA INDICATES THE AIR HANDLER IS NOT | | CAPABLE OF PRODUCING OVER 2000 CFMS OF SUPPLY AIR. | | PLEASE SEE PAGE 6 OF THE SUBMITTED PRODUCT DATA FOR THE | | CARRIER FAN COIL UNITS. THERE IS A NOTE BELOW THE | | PERFORMANCE DATA CHART INDICATING AIR FLOW CAN BE | | ADJUSTED +15% OR -10%. THEREFORE AHU-2 (060 IN THE | | TABLE) IS CAPABLE OF PRODUCING 2012 CFMS WHICH REQUIRES | | INSTALLATION OF A DS DETECTOR. | | | | 4) SUBMIT AC COOLING AND HEATING CALCULATIONS FOR THE | | NEW SYSTEMS- SECTION C403.2.2 FBC EC. | | THE AC CALCULATIONS INDICATE THE COOLING COIL AT 3.5 | | TONS FOR THE GREAT ROOM HP/AHU-2 SYSTEM, HOWEVER THE | | SYSTEM SELECTED IS A 5-TON AS SHOWN ON SHEET M-601. THE | | UNIT APPEARS TO BE OVERSIZED- SECTION C403.2.1 FBC EC. | | | | 6) PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL | | ROOMS AND SPACES PER TABLE 403.3.1.1 FBC ML. PROVIDE A | | SCHEDULE ON THE PLAN THAT INDICATES THE REQUIRED AND | | PROVIDED CFMS OF OUTDOOR AIR. | | THE VENTILATION CALCULATIONS ON SHEET M-101 CAN NOT BE | | CHECKED FOR COMPLIANCE WITH TABLE 403.3.1.1 FBC M | | BECAUSE THEY DO NOT INDICATE THE REQUIRED CFMS PER | | PERSON AND CFMS PER SQ. FT. OF THE ROOMS OR SPACES. | | PLEASE PROVIDE A COMPLETE CALCULATION TABLE. | | | | 8) PROVIDE ENGINEERING FOR INSTALLATION OF THE | | CONDENSER PAD AND MOUNTING OF THE CONDENSERS- SECTION | | 301.15 FBC M. | | MOUNTING PAD DETAILS HAVE BEEN PROVIDED BUT NO DETAILS | | FOR ANCHORING THE HEAT PUMPS TO THE SLABS. PLEASE NOTE | | THAT THE ENGINEERING MAY BE DEFERRED BY REQUEST- | | SECTION 107.3.4.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2020-03-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-03-11 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-03-11 |
Time |
12:56 |
Sent To |
|
|
Notes |
2020-03-11 15:35:10 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #20020745 | | 3/11/20 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-101: AIR HANDLERS ARE NOT ALLOWED IN THE | | ATTICS OF COMMERCIAL BUILDINGS- SECTION C403.2.9.6 FBC | | EC. THE UNITS WILL HAVE TO BE RELOCATED. | | | | 2 )M-101: PLEASE NOTE THAT AUTOMATIC SHUTOFF DAMPERS, | | EITHER MOTORIZED OR GRAVITY, WILL BE REQUIRED FOR THE | | O/A INTAKES TO THE RELOCATED AIR HANDLERS- SECTION | | C403.2.4.3 FBC EC. | | | | 3) M-101: PROVIDE A DUCT SMOKE DETECTOR IN THE SUPPLY | | SYSTEM OF AHU-2 PER SECTION 606.2.1 FBC M. PLEASE NOTE | | THAT AN EXEMPTION CAN BE APPLIED IF THE MANUFACTURER'S | | PERFORMANCE DATA INDICATES THE AIR HANDLER IS NOT | | CAPABLE OF PRODUCING OVER 2000 CFMS OF SUPPLY AIR. | | | | 4) SUBMIT AC COOLING AND HEATING CALCULATIONS FOR THE | | NEW SYSTEMS- SECTION C403.2.1 FBC EC. | | | | 5) SUBMIT AN ENERGY COMPLIANCE REPORT FOR THE NEW | | TENNIS CENTER- SEE SECTIONS C101.5 AND C401.2 FBC EC | | FOR COMPLIANCE AND SUBMITTAL INFORMATION. | | | | 6) PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL | | ROOMS AND SPACES PER TABLE 403.3.1.1 FBC ML. PROVIDE A | | SCHEDULE ON THE PLAN THAT INDICATES THE REQUIRED AND | | PROVIDED CFMS OF OUTDOOR AIR. | | | | 7) PROVIDE A CONDENSATE DISPOSAL PLAN- SECTION 307.2.1 | | FBC M. | | | | 8) PROVIDE ENGINEERING FOR INSTALLATION OF THE | | CONDENSER PAD AND MOUNTING OF THE CONDENSERS- SECTION | | 301.15 FBC M. | | | | 9) A-152 & A-203: A) A MINIMUM 30 INCHES DEEP AND 30 | | INCHES WIDE LEVEL PLATFORM WITH 42" HIGH GUARD RAILS | | SHALL BE PROVIDED FOR SERVICE AND REPLACEMENT OF THE | | ROOFTOP EXHAUST FANS- SECTION 306.5.1 FBC M. B) A | | RECEPTACLE OUTLET SAHLL BE POVIDED AT OR NEAR THE FANS | | IN ACCORDANCE WITH NFPA 70- SECTION 306.5.2 FBC M. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | UPDATED. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2020-05-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-05-14 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-05-14 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2020-04-14 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2020-04-14 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2020-04-14 |
Time |
05:45 |
Sent To |
|
|
Notes |
2020-04-14 10:57:42 | 1) SHT. A-411 & SHT. A-102 - DETAIL #1 - SHOW THE CLEAR | | FLOOR SPACE FOR THE HANDICAP ACCESSIBLE WATER CLOSETS | | ON THE ENLARGED FLOOR PLANS. COMPLY WITH 2017 | | FBC-ACCESS. SEC. 604.3. SHOW THE LENGTH AND WIDTH | | DIMENSIONS OF THE CLEAR FLOOR SPACE ON THE PLANS.THE | | ONLY CLEAR FLOOR SPACE SHOWN IS FOR THE LAVATORY. 2ND | | REQUEST. | | 2) SHT. A-102 - WOMEN'S AND MEN'S RESTROOMS #115 & 116 | | - A LAVATORY IS REQUIRED IN THE ACCESSIBLE TOILET | | STALLS PER 2017 FBC-ACCESS.SEC. 604.8.1.6. 2ND REQUEST. | | 3) SHT. A-102 - MEN'S & WOMEN'S RESTROOMS #115 & #116 - | | THE DOORSIN THE HANDICAP ACCESSIBLE TOILET STALLS SHALL | | BE LOCATED IN THE FRONT PARTITION OR IN THE SIDE WALL | | OR PARTITION FARTHEST FROM THE WATER CLOSET, NOT | | LOCATED DIRECTLY IN FRONT OF THE WATER CLOSET.2017 FBC- | | ACCESS. SEC.604.8.1.2. 2ND REQUEST. | | 4) THE WATER COOLER LOCATED ON THE EAST WALL OF THE | | RESTROOM FACILITY SHALL BE A HI-LO UNIT OR 2 SEPARATE | | UNITS COMPLYING WITH THE FBC-ACCESS. SEC. 211.1 & | | FBC-PLUMBING SEC.410.3. THIS WAS OVERLOOKED ON THE | | PREVIOUS REVIEW. | | 5) SHT. A-401 - VERTICAL GRAB BARS ARE SHOWN IN THE | | ACCESSIBILITY DETAILS. SEC. 609.4 OF THE FBC-ACCESS. | | STATES THAT GRAB BARS SHALL BE INSTALLED IN THE | | HORIZONTAL POSITION.THERE IS NO EXCEPTION IN THE | | ACCESSIBILITY CODE ALLOWING GRAB BARS TO BE INSTALLED | | IN A VERTICAL POSITION EVEN THOUGH THEY ARE NOT | | "REQUIRED" GRAB BARS. | | 6) SHT. P-601 - WATER HEATER SCHEDULE - IN THE "NOTES" | | COLUMN REFERENCE IS MADE TO NUMBERED NOTES BUT THERE | | ARE NO NUMBERED NOTES SHOWN. CLARIFY. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2020-03-13 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2020-03-13 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2020-03-13 |
Time |
12:06 |
Sent To |
|
|
Notes |
2020-03-13 12:29:47 | 1) SHOW THE CLEAR INSIDE DIMENSIONS (L X W) FOR THE | | ACCESSIBLE TOILET STALLS AND TOILET ROOMS ON THE | | ENLARGED FLOOR PLANS. , WPB AMEND. TO FBC SEC. 107.2.1. | | 2) SHOW THE CLEAR FLOOR SPACE FOR THE HANDICAP | | ACCESSIBLE WATER CLOSETS ON THE ENLARGED FLOOR PLANS. | | COMPLY WITH 2017 FBC-ACCESS. SEC. 604.3. SHOW THE | | LENGTH AND WIDTH DIMENSIONS OF THE CLEAR FLOOR SPACE ON | | THE PLANS. | | 3) SHT.A102 - WOMEN'S AND MEN'S RESTROOMS #115 & 116 - | | A LAVATORY IS REQUIRED IN THE ACCESSIBLE TOILET STALL | | PER 2017 FBC-ACCESS. SEC.604.8.1.6. SHOW THIS ON ALL | | APPLICABLE PLANS. | | 4) SHT. A101 - THE TOILET ROOMS IN THE TENNIS CENTER | | ARE LABELED AS UNISEX.THE TOILET ROOMS SHALL BE LABELED | | AS GENDER SPECIFIC PER 2017 FBC-PLUMBING SEC.403.2. | | 5) SHT. A401 - ALL GRAB BARS SHALL BE MEASURED FROM THE | | FINISH FLOOR TO THE TOP OF THE GRIPPING SURFACE PER | | 2017 FBC-ACCESS. SEC.609.4. | | 6) SHOW THE CLEAR INSIDE DIMENSIONS (L X W) OF ALL THE | | SHOWERS. WPB AMEND. TO FBC . SEC.107.2.1. | | 7) SUBMIT AN ENLARGED FLOOR FLOOR PLAN FOR THE MEN'S | | TOILET ROOM IN THE RESTROOM FACILITY.WPB AMEND. TO FBC | | SEC. 107.2.1. | | 8) A BACKFLOW PREVENTION DEVCE IS REQUIRED ON THE WATER | | SERVICE FOR THE TENNIS CENTER AND THE RESTROOM FACILITY | | PER THE CITY OF WEST PALM BEACH CROSS CONNECTION | | CONTROL MANUAL.. A SEPARATE PERMIT IS REQUIRED FOR THE | | BACKFLOW DEVICES. | | 9) SUBMIT MANUFACTURER'S SPECIFICATIONS AND SHOP | | DRAWINGS FOR THE RAINWATER COLLECTION SYSTEM. WPB | | AMEND. TO FBC SEC. 107.2.1. | | 10) NONPOTABLE WATER SYSTEMS SHALL BE IDENTIFIED IN | | ACCORDANCE WITH 2017 FBC-PLUMBING SECS.608.8 - | | 608.8.2.3. | | 11) SHT. P104 - DETAIL # 1- RESTROOM FACILITY - THE 3/4 | | INCH CW LINES HAS A NOTE THAT READS" SEE 1/P101 FOR | | CONTINUATION". SHT. P101 IS FOR THE TENNIS CENTER AND | | THE LINE IS NOT SHOWN. CLARIFY. | | 12) SHT. P104 - DETAIL #1 - THE WATER RISER SHOWS A 2 | | INCH NPW BY FIXTURES P3, P7 & IM LINE TO NOWHERE. | | CLARIFY. | | 13) SHT.P104 - THERE IS AN NPW LINE BY THE 1 1/2 NPW | | LINE TO P1A THAT HAS NO SIZE AND GOES NOWHERE. CLARIFY. | | 14) SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | INSTALLATION MANUAL FOR THE FILTRATION SKID. WPB AMEND. | | TO FBC SEC. 107.2.1. | | 15) BACK TO BACK WATER CLOSET CONNECTIONS SHALL COMPLY | | WITH 2017 FBC-PLUMBING SEC. 706.3 (EXCEPTION). SHOW | | COMPLIANCE ON PLANS. | | 16) SHT. P105 - DETAIL #1 SHOWS SANITARY TEES USED IN | | THE HORIZONTAL POSITION WHICH IS NOT PERMITTED PER 2017 | | FBC-PLUMBING TABLE 706.3. ALSO, THE PIPING TO FIXTURE | | P3 IS S- TRAPPED. | | 17) SHT. P501 - THE T & P LINE FOR THE WATER HEATER | | SHALL DISCHARGE THROUGH AN AIR GAP LOCATED IN THE SAME | | ROOM AS THE WATER HEATER. 2017 FBC-PLUMBING SEC.504.6. | | 18) SUBMIT THE MANUFACTURER'S SPECIFICATIONS FOR THE | | WATTS ES-LSMMV-M1. DEVICES USED FOR TEMPERING WATER | | SHALL CONFORM TO ASSE 1070 PER 2017 FBC-PLUMBING SEC. | | 607.1.2. | | 19) AS OF APRIL 16, 2015 THE MINIMUM ENERGY FACTOR FOR | | THE 10 GALLON STORAGE WATER HEATER IS .95 PER 10 CFR | | 430.32. THE ENERGY FACTOR FOR THE 66 GALLON STORAGE | | WATER HEATER SHALL BE 1.98. SHOW THESE CHANGES ON THE | | ENERGY CALCULATIONS. | | 20) THE GRAB BARS IN THE ACCESSIBLE SHOWERS SHALL BE | | INSTALLED 6 INCHES MAXIMUM FROM ADJACENT WALLS. 2017 | | FBC-ACCESS. SEC.608.3.2. | | 21)THE CONTROLS IN THE ACCESSIBLE SHOWERS SHALL BE | | LOCATED 27 INCHES MAXIMUM FROM THE SEAT WALL. SHOW THIS | | ON THE FLOOR PLANS. 2017 FBC-ACCESS. SEC. 608.5.2. | | 22) THE DOORS IN THE HANDICAP ACCESSIBLE TOILET STALLS | | SHALL BE LOCATED IN THE FRONT PARTITION OR IN THE SIDE | | WALL OR PARTITION FARTHEST FROM THE WATER CLOSET, NOT | | LOCATED DIRECTLY IN FRONT OF THE WATER CLOSET.. 2017 | | FBC_ ACCESS. SEC.604.8.1.2. | | 23) SHT. P104 - DETAIL #1 - THE 3/4 INCH NPW LINE IS | | ALSO NOTED AS "CW". CLARIFY. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
N |
Date |
2020-05-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-05-14 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-05-14 |
Time |
15:36 |
Sent To |
|
|
Notes |
2020-05-14 15:38:55 | DEFERRED SUBMITTAL |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2020-04-13 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2020-04-13 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2020-04-13 |
Time |
16:54 |
Sent To |
|
|
Notes |
2020-04-13 16:54:56 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2020-03-13 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2020-03-13 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2020-03-11 |
Time |
13:16 |
Sent To |
|
|
Notes |
2020-03-13 17:02:30 | SEE BUILDING COMMENT #7 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2020-05-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-05-16 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-05-16 |
Time |
13:09 |
Sent To |
|
|
Notes |
2020-05-16 13:09:37 | NOTIFIED ENGINEER THAT FUTURE SUBMITTALS WILL BE | | REQUIRED TO HAVE 3RD PARTY SIGNATURE | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2020-05-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2020-05-14 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2020-05-14 |
Time |
16:50 |
Sent To |
|
|
Notes |
2020-05-14 16:52:47 | ALL MECHANICAL, ELECTRICAL, AND PLUMBING SHEETS HAVE | | BEEN SELF-CERTIFIED BY THE ENGINEER OF RECORD. PER THE | | WPB AMENDMENTS TO THE FBC, FLORIDA ADMINISTRATIVE CODE | | RULE 61G15-23, EACH SHEET OF PLAN IS REQUIRED TO BE | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | WITH THE PROPER THIRD PARTY VERIFICATION. | | SELF-CERTIFICATION IS NOT ACCEPTABLE FOR ENGINEERS. | | PROVIDE CORRECTION. WPB FBC 107.1; FS 471/481 | | | | PREVIOUS COMMENTS NOT CORRECTED: | | ALL A SHEETS OK. | | ALL SHEETS DIGITALLY SIGNED BY ENGINEER NEED TO FOLLOW | | RULES ESTABLISHED BY THE BOARD OF ENGINEERS (SEE | | BELOW). | | | | 61G15-23 PE RULES FAC, FS 471 ENGINEERING FS | | DIGITALLY SIGN WITH A DIGITAL SIGNATURE ISSUED TO YOU | | BY A 3RD PARTY CERTIFICATION AUTHORITY. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2020-04-10 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-04-10 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-04-10 |
Time |
14:57 |
Sent To |
|
|
Notes |
2020-04-10 14:54:50 | ALL MECHANICAL, ELECTRICAL, AND PLUMBING SHEETS HAVE | | BEEN SELF-CERTIFIED BY THE ENGINEER OF RECORD. PER THE | | WPB AMENDMENTS TO THE FBC, FLORIDA ADMINISTRATIVE CODE | | RULE 61G15-23, EACH SHEET OF PLAN IS REQUIRED TO BE | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | WITH THE PROPER THIRD PARTY VERIFICATION. | | SELF-CERTIFICATION IS NOT ACCEPTABLE FOR ENGINEERS. | | PROVIDE CORRECTION. WPB FBC 107.1; FS 471/481 | | | | PREVIOUS COMMENTS NOT CORRECTED: | | ALL A SHEETS OK. | | ALL SHEETS DIGITALLY SIGNED BY ENGINEER NEED TO FOLLOW | | RULES ESTABLISHED BY THE BOARD OF ENGINEERS (SEE | | BELOW). | | | | 61G15-23 PE RULES FAC, FS 471 ENGINEERING FS | | DIGITALLY SIGN WITH A DIGITAL SIGNATURE ISSUED TO YOU | | BY A 3RD PARTY CERTIFICATION AUTHORITY. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2020-03-11 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2020-03-11 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2020-03-11 |
Time |
13:12 |
Sent To |
|
|
Notes |
2020-03-11 13:15:23 | OK A-SHEETS | | ALL SHEETS DIGITALLY SIGNED BY ENGINEER NEED TO FOLLOW | | RULES ESTABLISHED BY THE BOARD OF ENGINEERS (SEE | | BELOW). | | | | 61G15-23 PE RULES FAC, FS 471 ENGINEERING FS | | DIGITALLY SIGN WITH A DIGITAL SIGNATURE ISSUED TO YOU | | BY A 3RD PARTY CERTIFICATION AUTHORITY. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2020-05-18 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2020-05-18 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2020-04-15 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2020-04-15 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2020-04-15 |
Time |
09:35 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2020-03-06 |
|
|
Cont ID |
|
Sent By |
hdanfort |
Date |
2020-03-06 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
hmtribou |
Date |
2020-03-06 |
Time |
14:14 |
Sent To |
|
|
Notes |
|
|