2020-03-02 11:30:17 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 20020602 |
| ADD: 1700 PALM BEACH LAKES BLVD. |
| CONT: FERRIN SIGNS |
| TEL: 561-802-4242 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION. |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: MONDAY MARCH 02/2020 |
| ACTION: DENIED |
| |
| 1) THE DESCRIPTION GIVEN ON THE PERMIT IS VAGUE, |
| MONUMENT SIGNS, IS THIS A FACE CHANGE ON A MONUMENT |
| SIGN OR A WHOLE NEW MONUMENT SIGN, INCLUDING THE |
| FOUNDATION, STRUCTURAL SUPPORT POLE, BASE CABINET AND |
| STRUCTURAL FRAMEWORK AND DOUBLE FACED SIGN? 107.2.1.2 |
| ADDITIONAL INFORMATION IS REQUIRED. I?M DOING THIS |
| REVIEW AS A WHOLE NEW INSTALLATION. |
| |
| 2) THE VALUE OF $6,000.00 DOLLARS IS EXTREMELY LOW FOR |
| THE SCOPE OF WORK. |
| 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATIVE CODE |
| 108.3* BUILDING PERMIT VALUATION. IF, IN THE OPINION OF |
| THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF |
| BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, |
| MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE UNDER |
| ESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE |
| DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, |
| VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL |
| REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, |
| PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE |
| WORK (EXCAVATION AND BACKFILL FOR BUILDINGS), |
| ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD |
| AND PROFIT; EXCLUDING ONLY LAND VALUE. VALUATION |
| REFERENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF |
| NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| CONGRESS. |
| |
| 3) THERE ARE NO STRUCTURAL PLANS AND CALCULATIONS FOR |
| THE FOUNDATION, SIZE AND DEPTH OF THE FOOTER NOR THE |
| STEEL REINFORCEMENT FOR THE FOOTER. THE PLANS DO NOT |
| INDICATE THE DIAMETER OF THE STEEL TUBE, WALL |
| THICKNESS, EMBEDMENT INTO THE FOOTER NOR CALCULATIONS |
| FOR WIND SPEED AND AFFECTED SQ. FOOT AREA OF THE SIGN, |
| AND WIND SPEED THE SIGN IS DESIGNED TOO. |
| |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE |
| DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| ELECTRONIC MEDIA DOCUMENTS SHALL BE |
| SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. |
| CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK PROPOSED AND SHOW IN DETAIL |
| THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, RULES AND |
| REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. |
| |
| 107.2.1.2 ADDITIONAL DATA. THE BUILDING OFFICIAL MAY |
| REQUIRE DETAILS, COMPUTATIONS, STRESS DIAGRAMS, AND |
| OTHER DATA NECESSARY TO DESCRIBE THE CONSTRUCTION OR |
| INSTALLATION AND THE BASIS OF CALCULATIONS. |
| 4) DESIGN DOCUMENTS FOR WIND WILL NEED TO BE DESIGNED |
| BY A LICENSED PROFESSIONAL. 107.1 SUBMITTAL DOCUMENTS |
| CONSISTING OF CONSTRUCTION DOCUMENTS, GEOTECHNICAL |
| REPORT AND OTHER DATA SHALL BE SUBMITTED IN TWO SETS |
| WITH EACH PERMIT APPLICATION. THE CONSTRUCTION |
| DOCUMENTS SHALL BE PREPARED BY A REGISTERED DESIGN |
| PROFESSIONAL WHERE REQUIRED BY CHAPTER 471, FLORIDA |
| STATUTES & 61G15 FLORIDA ADMINISTRATIVE CODE OR CHAPTER |
| 481, FLORIDA STATUTES & 61G1 FLORIDA ADMINISTRATIVE |
| CODE. |
| |
| 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE |
| THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED |
| DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE |
| MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS |
| AND INFORMATION LACKING UNDER THE PRIOR REVIEW. |
| |
| |
| JAMES A. WITMER BN, PX, SFP & CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |