Plan Review Details - Permit 20020602
Plan Review Stops For Permit 20020602
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-03-22 Cont ID  
Sent By shill Date 2020-03-22 Time 10:26 Rev Time 0.00
Received By shill Date 2020-03-22 Time 10:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-02 Cont ID  
Sent By jwitmer Date 2020-03-02 Time 11:30 Rev Time 0.00
Received By jwitmer Date 2020-03-02 Time 06:31 Sent To  
Notes
2020-03-02 11:30:172017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20020602
 ADD: 1700 PALM BEACH LAKES BLVD.
 CONT: FERRIN SIGNS
 TEL: 561-802-4242
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MONDAY MARCH 02/2020
 ACTION: DENIED
  
 1) THE DESCRIPTION GIVEN ON THE PERMIT IS VAGUE,
 MONUMENT SIGNS, IS THIS A FACE CHANGE ON A MONUMENT
 SIGN OR A WHOLE NEW MONUMENT SIGN, INCLUDING THE
 FOUNDATION, STRUCTURAL SUPPORT POLE, BASE CABINET AND
 STRUCTURAL FRAMEWORK AND DOUBLE FACED SIGN? 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED. I?M DOING THIS
 REVIEW AS A WHOLE NEW INSTALLATION.
  
 2) THE VALUE OF $6,000.00 DOLLARS IS EXTREMELY LOW FOR
 THE SCOPE OF WORK.
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATIVE CODE
 108.3* BUILDING PERMIT VALUATION. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE UNDER
 ESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL,
 PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE
 WORK (EXCAVATION AND BACKFILL FOR BUILDINGS),
 ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD
 AND PROFIT; EXCLUDING ONLY LAND VALUE. VALUATION
 REFERENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF
 NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 3) THERE ARE NO STRUCTURAL PLANS AND CALCULATIONS FOR
 THE FOUNDATION, SIZE AND DEPTH OF THE FOOTER NOR THE
 STEEL REINFORCEMENT FOR THE FOOTER. THE PLANS DO NOT
 INDICATE THE DIAMETER OF THE STEEL TUBE, WALL
 THICKNESS, EMBEDMENT INTO THE FOOTER NOR CALCULATIONS
 FOR WIND SPEED AND AFFECTED SQ. FOOT AREA OF THE SIGN,
 AND WIND SPEED THE SIGN IS DESIGNED TOO.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE
 SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL
 THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 107.2.1.2 ADDITIONAL DATA. THE BUILDING OFFICIAL MAY
 REQUIRE DETAILS, COMPUTATIONS, STRESS DIAGRAMS, AND
 OTHER DATA NECESSARY TO DESCRIBE THE CONSTRUCTION OR
 INSTALLATION AND THE BASIS OF CALCULATIONS.
 4) DESIGN DOCUMENTS FOR WIND WILL NEED TO BE DESIGNED
 BY A LICENSED PROFESSIONAL. 107.1 SUBMITTAL DOCUMENTS
 CONSISTING OF CONSTRUCTION DOCUMENTS, GEOTECHNICAL
 REPORT AND OTHER DATA SHALL BE SUBMITTED IN TWO SETS
 WITH EACH PERMIT APPLICATION. THE CONSTRUCTION
 DOCUMENTS SHALL BE PREPARED BY A REGISTERED DESIGN
 PROFESSIONAL WHERE REQUIRED BY CHAPTER 471, FLORIDA
 STATUTES & 61G15 FLORIDA ADMINISTRATIVE CODE OR CHAPTER
 481, FLORIDA STATUTES & 61G1 FLORIDA ADMINISTRATIVE
 CODE.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
  
 JAMES A. WITMER BN, PX, SFP & CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-03-18 Cont ID  
Sent By jleahy Date 2020-03-18 Time 14:33 Rev Time 0.00
Received By jleahy Date 2020-03-18 Time 14:33 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-02-24 Cont ID  
Sent By fgiaquin Date 2020-02-24 Time 06:25 Rev Time 0.00
Received By fgiaquin Date 2020-02-24 Time 05:54 Sent To I
Notes
2020-02-24 06:07:30ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND
 SIGNED/SEALED BY A DESIGN PROFESSIONAL OR SIGNED BY THE
 ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS
 471.003(2)(H); 471.025; WPB FBC 107.1
  
 2. VALUE LOW FOR AMOUNT OF WORK SHOWN.
  
 CITY ORDINANCE AND FBC 109.3 BUILDING PERMIT
 VALUATIONS. IF, IN THE OPINION OF THE BUILDING
 OFFICIAL, THE CLAIMED VALUATION OF BUILDING,
 ALTERATION, STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR
 PLUMBING SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE
 APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR
 BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO
 MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR
 PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS
 SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 3. EACH SIGN AND OUTLINE LIGHTING SYSTEM, OR FEEDER
 CIRCUIT OR BRANCH CIRCUIT SUPPLYING A SIGN OR OUT-LINE
 LIGHTING SYSTEM, SHALL BE CONTROLLED BY AN EXTERNALLY
 OPERABLE SWITCH OR CIRCUIT BREAKER THAT WILL OPEN ALL
 UNGROUNDED CONDUCTORS WITHIN SIGHT OF THE SIGN NEC
 600.6(A)(1)
  
 4. ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 405.1
 SHALL HAVE AUTOMATIC CONTROLS TO TURN OFF AT DAYLIGHT
 OR WHEN NOT REQUIRED. CONTROLS SHALL BE PHOTOSENSOR &
 TIME CLOCK OR ASTRONOMICAL TIME SWITCH. ALL TIME
 SWITCHES SHALL BE CAPABLE OF RETAINING PROGRAMING
 DURING A LOSS OF POWER FOR A MINIMUM OF 10 HOURS.
 FBC-EC 405.2.5. PROVIDE COMPLIANCE
  
 5. SEPARATE ELECTRICAL PERMIT FOR NEW 120V CIRCUIT TO
 MONUMENT SIGN REQUIRED BY LICENSED ELECTRICIAN.
 REFERENCE PERMIT NUMBER OF SEPARATE ELECTRICAL PERMIT
 WHEN RESUBMITTING TO SHOW COMPLIANCE. FBC 105.1, FBC
 107.2.1, F.S. 489.505 (#19) AND F.A.C. 61G6-7.001
 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN SPECIALTY
 CONTRACTOR)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-22 Cont ID  
Sent By shill Date 2020-03-22 Time 10:26 Rev Time 0.00
Received By shill Date 2020-03-10 Time 13:16 Sent To  
Notes
2020-03-21 11:30:423/21 ROUTED TO MISC 2
  
2020-03-16 16:43:383/16 ROUTED TO FGIAQUINTO
2020-03-11 13:16:11RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-03-02 Time   Rev Time 0.00
Received By lmarchan Date 2020-02-14 Time 13:17 Sent To  
Notes
2020-02-24 08:14:562/24 TO MISC 2
  
2020-02-20 18:06:05ROUTED TO ELECTRICAL INBOX
2020-02-18 13:17:36ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2020-03-16 Cont ID  
Sent By rfalcone Date 2020-03-16 Time 14:30 Rev Time 0.00
Received By rfalcone Date 2020-03-16 Time 14:30 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-02-19 Cont ID  
Sent By rfalcone Date 2020-02-19 Time 16:45 Rev Time 0.00
Received By rfalcone Date 2020-02-19 Time 16:45 Sent To I
Notes
2020-02-19 16:47:042/19/2020 FAILED.
  
 PLEASE REVISE THE SETBACKS TO COMPLY WITH ZONING
 REGULATIONS.
  
 SEC. 94-408(D)(2)(E.)MINIMUM SETBACKS:1.FROM LOT LINE
 OF ANOTHER LOT: 24 FEET. 2.FROM PUBLIC RIGHT-OF-WAY
 LINE: FIVE FEET.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 RACHEL FALCONE, ASSOCIATE PLANNER
 DEVELOPMENT SERVICES DEPARTMENT
 E-MAIL: [email protected]
 TEL: (561) 822-1442
  